395 813

Cited 0 times in

아디포넥틴 ELISA 검사 성능 평가와 한국인의 혈청 아디포넥틴 참고구간 설정

DC Field Value Language
dc.contributor.author박용정-
dc.contributor.author김현숙-
dc.date.accessioned2014-12-18T10:00:52Z-
dc.date.available2014-12-18T10:00:52Z-
dc.date.issued2013-
dc.identifier.issn2093-6338-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/89253-
dc.description.abstractBackground : Adiponectin is a plasma protein secreted by adipose tissues and low serum adiponectin concentration has been reported to be associated with insulin resistance and metabolic syndrome (MS). We evaluated the performance of an ELISA-based assay for measuring serum adiponectin levels and established reference intervals of adiponectin for Korean population. Methods : Laboratory performance, including precision and linearity, of the AdipoMark Human Adiponectin ELISA kit (Mesdia Co., Korea) was assessed. Reference intervals of adiponectin concentration were determined after evaluation of 1200 subjects with no history of MS. Adiponectin was also measured in 100 patients with MS. Results : The mean concentrations of serum samples tested for precision evaluation were 6.66, 12.61, and 23.42 µg/mL: the ELISA showed total imprecision of 13.6%, 9.3%, and 10.5% CV for the respective concentrations. The assay demonstrated linear responses in the range of 1.8-29.9 µg/mL serum adiponectin levels. The 95% reference intervals for Korean population were 3.6-19.2 µg/mL for men and 4.5-34.2 µg/mL for women. ROC-area under the curve values of adiponectin for the diagnosis of MS were 0.85 for men and 0.83 for women. Low adiponectin level was independently associated with MS in the multivariate analysis. Conclusions : The adiponectin quantitation assay evaluated in this study showed acceptable laboratory and clinical performances in an ELISA platform. To meet the ever-increasing demand for a reliable assay for measuring adiponectin levels in the study of various metabolic diseases, this assay could be further improved by the automation of the platform.-
dc.description.statementOfResponsibilityopen-
dc.relation.isPartOfLaboratory Medicine Online-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.title아디포넥틴 ELISA 검사 성능 평가와 한국인의 혈청 아디포넥틴 참고구간 설정-
dc.title.alternativeEvaluation of the Performance of an Adiponectin ELISA-based Test and Establishing Serum Adiponectin Reference Intervals for Korean Population-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Laboratory Medicine (진단검사의학)-
dc.contributor.googleauthor박용정-
dc.contributor.googleauthor김영란-
dc.contributor.googleauthor김현숙-
dc.identifier.doi10.3343/lmo.2013.3.4.242-
dc.admin.authorfalse-
dc.admin.mappingfalse-
dc.contributor.localIdA01582-
dc.contributor.localIdA01117-
dc.relation.journalcodeJ02151-
dc.identifier.pmidAdiponectin ; Laboratory performance ; Precision ; Reference interval-
dc.subject.keywordAdiponectin-
dc.subject.keywordLaboratory performance-
dc.subject.keywordPrecision-
dc.subject.keywordReference interval-
dc.contributor.alternativeNamePark, Yong Jung-
dc.contributor.alternativeNameKim, Hyon Suk-
dc.contributor.affiliatedAuthorPark, Yong Jung-
dc.contributor.affiliatedAuthorKim, Hyon Suk-
dc.rights.accessRightsfree-
dc.citation.volume3-
dc.citation.number4-
dc.citation.startPage242-
dc.citation.endPage252-
dc.identifier.bibliographicCitationLaboratory Medicine Online, Vol.3(4) : 242-252, 2013-
dc.identifier.rimsid34483-
dc.type.rimsART-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Laboratory Medicine (진단검사의학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.