3 547

Cited 32 times in

Transcatheter closure of perimembranous ventricular septal defect using Amplatzer ductal occluder

Authors
 Sang Mi Lee  ;  Jin Young Song  ;  Jae Young Choi  ;  Sang Yoon Lee  ;  Jae Sook Paik  ;  So Ick Chang  ;  Woo Seop Shim  ;  Seong Ho Kim 
Citation
 CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, Vol.82(7) : 1141-1146, 2013 
Journal Title
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS
ISSN
 1522-1946 
Issue Date
2013
MeSH
Adolescent ; Adult ; Atrioventricular Block/etiology ; Cardiac Catheterization/adverse effects ; Cardiac Catheterization/instrumentation* ; Child ; Child, Preschool ; Female ; Heart Septal Defects, Ventricular/diagnosis ; Heart Septal Defects, Ventricular/physiopathology ; Heart Septal Defects, Ventricular/therapy* ; Hemodynamics ; Humans ; Male ; Prosthesis Design ; Septal Occluder Device* ; Time Factors ; Treatment Outcome ; Ventricular Function
Keywords
Adolescent ; Adult ; Atrioventricular Block/etiology ; Cardiac Catheterization/adverse effects ; Cardiac Catheterization/instrumentation* ; Child ; Child, Preschool ; Female ; Heart Septal Defects, Ventricular/diagnosis ; Heart Septal Defects, Ventricular/physiopathology ; Heart Septal Defects, Ventricular/therapy* ; Hemodynamics ; Humans ; Male ; Prosthesis Design ; Septal Occluder Device* ; Time Factors ; Treatment Outcome ; Ventricular Function
Abstract
OBJECTIVE: To show that transcatheter closure of perimembranous ventricular septal defect (PMVSD) with the Amplatzer ductal occluder (ADO, AGA Medical Corp, Plymouth, Minnesota) is a safe and effective treatment option.
BACKGROUND: Transcatheter closure of PMVSD is a challenging procedure. Recently, the Amplatzer PMVSD occluder (APMVSDO, AGA Medical Corp, Plymouth, Minnesota) has been shown to be effective in closing hemodynamically significant PMVSDs. However, the high incidence of complete atrioventricular block (CAVB) after device occlusion of a PMVSD has been a hot issue as well.
METHODS: Among several devices used in closing PMVSD percutaneously, we prefer the ADO because of the anatomic resemblance between PMVSD with aneurysm and patent ductus arteriosus, and it has no right ventricular disc which may contribute to the occurrence of CAVB.
RESULTS: Between August 2009 and May 2012, 21 patients (5 males and 16 females) underwent percutaneous PMVSD closure using ADO. The patients' ages ranged from 3 to 42 years (median: 7 years), and their weights ranged from 18 kg to 60 kg (median: 27 kg). All patients showed echocardiographic signs of left ventricular volume overload and trivial to small mitral regurgitation (Qp/Qs = 1.7 ± 0.4). The mean defect size of the right ventricular side was 4.3 ± 1.0 mm. Devices 2 mm larger than the measured narrowest VSD diameter were selected in most patients. The ADOs were successfully implanted in all patients without any significant complications except one transient CAVB, one case of delivery wire fracture, and one case of surgery due to significant residual leak. Small residual shunts were observed immediately after the device implantation, but they disappeared during follow-up for 18 of 20 patients. The mean follow-up period was 20 ± 9 months, and CAVB or aortic regurgitation was not observed in all patients.
CONCLUSION: Transcatheter closure of PMVSD with the ADO is a safe and promising treatment option, but long-term follow-up in a large number of patients would be warranted.
Full Text
http://onlinelibrary.wiley.com/doi/10.1002/ccd.24810/abstract
DOI
10.1002/ccd.24810
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Pediatrics (소아과학교실) > 1. Journal Papers
Yonsei Authors
Choi, Jae Young(최재영) ORCID logo https://orcid.org/0000-0002-1247-6669
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/88948
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links