1 659

Cited 17 times in

Usefulness of intravascular ultrasound to predict outcomes in short-length lesions treated with drug-eluting stents

Authors
 Young-Won Yoon  ;  Sanghoon Shin  ;  Byeong-Keuk Kim  ;  Jung-Sun Kim  ;  Dong-Ho Shin  ;  Young-Guk Ko  ;  Donghoon Choi  ;  Dong-Woon Jeon  ;  Hyuckmoon Kwon  ;  Yangsoo Jang  ;  Myeong-Ki Hong 
Citation
 AMERICAN JOURNAL OF CARDIOLOGY, Vol.112(5) : 642-646, 2013 
Journal Title
AMERICAN JOURNAL OF CARDIOLOGY
ISSN
 0002-9149 
Issue Date
2013
MeSH
Aged ; Coronary Angiography ; Coronary Artery Disease/diagnostic imaging ; Coronary Artery Disease/mortality ; Coronary Artery Disease/therapy* ; Coronary Restenosis ; Coronary Vessels/diagnostic imaging* ; Drug-Eluting Stents* ; Female ; Humans ; Male ; Middle Aged ; Myocardial Infarction/prevention & control ; Percutaneous Coronary Intervention/methods* ; Prognosis ; Sirolimus/analogs & derivatives ; Treatment Outcome ; Ultrasonography, Interventional*
Keywords
Aged ; Coronary Angiography ; Coronary Artery Disease/diagnostic imaging ; Coronary Artery Disease/mortality ; Coronary Artery Disease/therapy* ; Coronary Restenosis ; Coronary Vessels/diagnostic imaging* ; Drug-Eluting Stents* ; Female ; Humans ; Male ; Middle Aged ; Myocardial Infarction/prevention & control ; Percutaneous Coronary Intervention/methods* ; Prognosis ; Sirolimus/analogs & derivatives ; Treatment Outcome ; Ultrasonography, Interventional*
Abstract
Intravascular ultrasound (IVUS) offers tomographic images of the coronary artery, helping physicians to refine drug-eluting stent (DES) implantation in angiographically complex lesions. However, controversy exists regarding whether the routine use of IVUS in short-length lesions leads to improved clinical outcomes after DES implantation. Therefore, we evaluated the usefulness of IVUS in predicting major adverse cardiac events (MACE), including cardiovascular death, myocardial infarction, or target vessel revascularization, at 1 year after DES implantation in short-length lesions. The present study was a subanalysis of the REal Safety and Efficacy of a 3-month dual antiplatelet Therapy following Endeavor zotarolimus-eluting stent implantation (RESET) study with different clinical outcome parameters. The study population consisted of 662 patients with IVUS guidance and 912 patients with angiography guidance who underwent DES implantation (stent length ≤24 mm). In the IVUS-guided group, adjuvant postdilation was more frequently performed (43.0% vs 34.6%, p <0.001), and the postintervention minimal lumen diameters were greater (2.88 ± 0.44 mm vs 2.72 ± 0.43 mm, p <0.001). MACE occurred in 15 IVUS-guided (2.3%) and 19 angiographically guided (2.1%) patients (p = 0.872). In a subset of patients with diabetes mellitus (n = 292), the MACE rate was 3.4% (n = 4) and 1.7% (n = 3) in the IVUS- and angiographically guided patients, respectively (p = 0.384). The MACE rate in the IVUS- and angiographically guided patients with acute coronary syndrome (n = 601) was 1.1% (n = 3) and 2.7% (n = 9), respectively (p = 0.194). The clinical benefits of IVUS-guided DES implantation compared with angiographically guided DES implantation in short-length lesions could not be confirmed even in patients with clinically high-risk presentations (acute coronary syndrome and diabetes mellitus). In conclusion, routine IVUS guidance does not provide clinical benefits when performing short-length DES implantation
Full Text
http://www.sciencedirect.com/science/article/pii/S0002914913010540
DOI
10.1016/j.amjcard.2013.04.037
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Internal Medicine (내과학교실) > 1. Journal Papers
Yonsei Authors
Ko, Young Guk(고영국) ORCID logo https://orcid.org/0000-0001-7748-5788
Kwon, Hyuck Moon(권혁문) ORCID logo https://orcid.org/0000-0001-9901-5015
Kim, Byeong Keuk(김병극) ORCID logo https://orcid.org/0000-0003-2493-066X
Kim, Jung Sun(김중선) ORCID logo https://orcid.org/0000-0003-2263-3274
Shin, Dong Ho(신동호) ORCID logo https://orcid.org/0000-0002-7874-5542
Shin, Sang Joon(신상준) ORCID logo https://orcid.org/0000-0001-5350-7241
Yoon, Young Won(윤영원) ORCID logo https://orcid.org/0000-0002-0907-0350
Jang, Yang Soo(장양수) ORCID logo https://orcid.org/0000-0002-2169-3112
Choi, Dong Hoon(최동훈) ORCID logo https://orcid.org/0000-0002-2009-9760
Hong, Myeong Ki(홍명기) ORCID logo https://orcid.org/0000-0002-2090-2031
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/87368
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links