Cited 15 times in
Efficacy and safety of the preclose technique following percutaneous aortic stent-graft implantation
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 고영국 | - |
dc.contributor.author | 신상준 | - |
dc.contributor.author | 장양수 | - |
dc.contributor.author | 최동훈 | - |
dc.contributor.author | 홍명기 | - |
dc.date.accessioned | 2014-12-18T08:58:38Z | - |
dc.date.available | 2014-12-18T08:58:38Z | - |
dc.date.issued | 2013 | - |
dc.identifier.issn | 1526-6028 | - |
dc.identifier.uri | https://ir.ymlib.yonsei.ac.kr/handle/22282913/87304 | - |
dc.description.abstract | PURPOSE: To evaluate in a large patient cohort the 6-F Perclose ProGlide in conjunction with the preclose technique to seal puncture sites after percutaneous endovascular aortic repairs. METHODS: The medical records were reviewed of 367 patients (303 men; mean age 68.5±10.8 years) having 599 access site closures with the 6-F Perclose ProGlide performed in conjunction with percutaneous endovascular aortic repairs. Procedure success was defined as hemostasis with the preclose technique without the need for any ancillary procedure. Access-related major adverse events included infection, bleeding, lower leg ischemia, hematoma, pseudoaneurysm, arteriovenous fistula, embolization, laceration, femoral artery thrombosis, nerve injury, or death owing to an access site injury. RESULTS: Procedure success was achieved in 359 (97.8%) of 367 patients and in 591 (98.7%) of 599 femoral sites. Access-related major adverse events developed in 25 (6.8%) of 367 patients [26/599 (4.3%) sites]. The most frequent adverse event was a hematoma [16/367 (4.4%) patients; 17/599 (2.8%) sites], followed by pseudoaneurysm [7/367 (1.9%) patients; 7/599 (1.2%) sites]. Bleeding occurred in 6 (1.6%) of 367 patients [6/599 (1.0%) sites]. There were 2 infections, 2 distal embolizations, 1 acute femoral thrombosis, and 1 laceration at the puncture site. CONCLUSION: The preclose technique can be used to achieve hemostasis with remarkable success and low rates of adverse events. | - |
dc.description.statementOfResponsibility | open | - |
dc.relation.isPartOf | JOURNAL OF ENDOVASCULAR THERAPY | - |
dc.rights | CC BY-NC-ND 2.0 KR | - |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-nd/2.0/kr/ | - |
dc.subject.MESH | Aged | - |
dc.subject.MESH | Aortic Diseases/surgery* | - |
dc.subject.MESH | Blood Vessel Prosthesis | - |
dc.subject.MESH | Blood Vessel Prosthesis Implantation/methods | - |
dc.subject.MESH | Endovascular Procedures/adverse effects | - |
dc.subject.MESH | Endovascular Procedures/methods* | - |
dc.subject.MESH | Female | - |
dc.subject.MESH | Humans | - |
dc.subject.MESH | Male | - |
dc.subject.MESH | Prosthesis Implantation/methods* | - |
dc.subject.MESH | Retrospective Studies | - |
dc.subject.MESH | Stents | - |
dc.subject.MESH | Suture Techniques/instrumentation* | - |
dc.title | Efficacy and safety of the preclose technique following percutaneous aortic stent-graft implantation | - |
dc.type | Article | - |
dc.contributor.college | College of Medicine (의과대학) | - |
dc.contributor.department | Dept. of Internal Medicine (내과학) | - |
dc.contributor.googleauthor | Won Ho Kim | - |
dc.contributor.googleauthor | Sanghoon Shin | - |
dc.contributor.googleauthor | Young-Guk Ko | - |
dc.contributor.googleauthor | Myeong-Ki Hong | - |
dc.contributor.googleauthor | Yangsoo Jang | - |
dc.contributor.googleauthor | Donghoon Choi | - |
dc.identifier.doi | 10.1583/12-4103MR2.1 | - |
dc.admin.author | false | - |
dc.admin.mapping | false | - |
dc.contributor.localId | A00127 | - |
dc.contributor.localId | A02105 | - |
dc.contributor.localId | A03448 | - |
dc.contributor.localId | A04053 | - |
dc.contributor.localId | A04391 | - |
dc.relation.journalcode | J01395 | - |
dc.identifier.eissn | 1545-1550 | - |
dc.identifier.pmid | 23731308 | - |
dc.identifier.url | http://jevtonline.org/doi/abs/10.1583/12-4103MR2.1 | - |
dc.subject.keyword | Aged | - |
dc.subject.keyword | Aortic Diseases/surgery* | - |
dc.subject.keyword | Blood Vessel Prosthesis | - |
dc.subject.keyword | Blood Vessel Prosthesis Implantation/methods | - |
dc.subject.keyword | Endovascular Procedures/adverse effects | - |
dc.subject.keyword | Endovascular Procedures/methods* | - |
dc.subject.keyword | Female | - |
dc.subject.keyword | Humans | - |
dc.subject.keyword | Male | - |
dc.subject.keyword | Prosthesis Implantation/methods* | - |
dc.subject.keyword | Retrospective Studies | - |
dc.subject.keyword | Stents | - |
dc.subject.keyword | Suture Techniques/instrumentation* | - |
dc.contributor.alternativeName | Ko, Young Guk | - |
dc.contributor.alternativeName | Shin, Sang Joon | - |
dc.contributor.alternativeName | Jang, Yang Soo | - |
dc.contributor.alternativeName | Choi, Dong Hoon | - |
dc.contributor.alternativeName | Hong, Myeong Ki | - |
dc.contributor.affiliatedAuthor | Ko, Young Guk | - |
dc.contributor.affiliatedAuthor | Shin, Sang Joon | - |
dc.contributor.affiliatedAuthor | Jang, Yang Soo | - |
dc.contributor.affiliatedAuthor | Choi, Dong Hoon | - |
dc.contributor.affiliatedAuthor | Hong, Myeong Ki | - |
dc.rights.accessRights | not free | - |
dc.citation.volume | 20 | - |
dc.citation.number | 3 | - |
dc.citation.startPage | 350 | - |
dc.citation.endPage | 355 | - |
dc.identifier.bibliographicCitation | JOURNAL OF ENDOVASCULAR THERAPY, Vol.20(3) : 350-355, 2013 | - |
dc.identifier.rimsid | 32964 | - |
dc.type.rims | ART | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.