1 491

Cited 9 times in

Comparison Between Magnetic Anchoring and Guidance System Camera-Assisted Laparoendoscopic Single-Site Surgery Nephrectomy and Conventional Laparoendoscopic Single-Site Surgery Nephrectomy in a Porcine Model: Focus on Ergonomics and Workload Profiles

DC Field Value Language
dc.contributor.author한웅규-
dc.date.accessioned2014-12-18T08:39:26Z-
dc.date.available2014-12-18T08:39:26Z-
dc.date.issued2013-
dc.identifier.issn0892-7790-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/86713-
dc.description.abstractPURPOSE: To compare surgeon-assessed ergonomic and workload demands of magnetic anchoring and guidance system (MAGS) laparoendoscopic single-site surgery (LESS) nephrectomy with conventional LESS nephrectomy in a porcine model. METHODS: Participants included two expert and five novice surgeons who each performed bilateral LESS nephrectomy in two nonsurvival animals using either the MAGS camera or conventional laparoscope. Task difficulty and workload demands of the surgeon and camera driver were assessed using the validated National Aeronautics and Space Administration Task Load Index (NASA-TLX) questionnaire. Surgeons were also asked to score 6 parameters on a Likert scale (range 1=low/easy to 5=high/hard): procedure-associated workload, ergonomics, technical challenge, visualization, accidental events, and instrument handling. Each step of the nephrectomy was also timed and instrument clashing was quantified. RESULTS: Scores for each parameter on the Likert scale were significantly lower for MAGS-LESS nephrectomy. Mean number of internal and external clashes were significantly lower for the MAGS camera (p<0.001). Mean task times for each procedure were shorter for experts than for novices, but this was not statistically significant. NASA-TLX workload ratings by the surgeon and camera driver showed that MAGS resulted in a significantly lower workload than the conventional laparoscope during LESS nephrectomy (p<0.05). CONCLUSIONS: The use of the MAGS camera during LESS nephrectomy lowers the task workload for both the surgeon and camera driver when compared to conventional laparoscope use. Subjectively, it appears to also improve surgeons' impressions of ergonomics and technical challenge. Pending approval for clinical use, further evaluation in the clinical setting is warranted.-
dc.description.statementOfResponsibilityopen-
dc.relation.isPartOfJOURNAL OF ENDOUROLOGY-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.subject.MESHAnimals-
dc.subject.MESHClinical Competence-
dc.subject.MESHErgonomics*-
dc.subject.MESHLaparoscopy/instrumentation*-
dc.subject.MESHMagnetics/instrumentation*-
dc.subject.MESHModels, Animal-
dc.subject.MESHNephrectomy/instrumentation*-
dc.subject.MESHNephrectomy/methods*-
dc.subject.MESHPhysicians-
dc.subject.MESHSus scrofa/surgery*-
dc.subject.MESHTime Factors-
dc.subject.MESHWorkload*-
dc.titleComparison Between Magnetic Anchoring and Guidance System Camera-Assisted Laparoendoscopic Single-Site Surgery Nephrectomy and Conventional Laparoendoscopic Single-Site Surgery Nephrectomy in a Porcine Model: Focus on Ergonomics and Workload Profiles-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Urology (비뇨기과학)-
dc.contributor.googleauthorWoong Kyu Han-
dc.contributor.googleauthorYung K. Tan-
dc.contributor.googleauthorEphrem O. Olweny-
dc.contributor.googleauthorGang Yin-
dc.contributor.googleauthorZhuo-Wei Liu-
dc.contributor.googleauthorStephen Faddegon-
dc.contributor.googleauthorDaniel J. Scott-
dc.contributor.googleauthorJeffrey A. Cadeddu-
dc.identifier.doi10.1089/end.2012.0484-
dc.admin.authorfalse-
dc.admin.mappingfalse-
dc.contributor.localIdA04308-
dc.relation.journalcodeJ01394-
dc.identifier.eissn1557-900X-
dc.identifier.pmid23067039-
dc.identifier.urlhttp://online.liebertpub.com/doi/abs/10.1089/end.2012.0484-
dc.subject.keywordAnimals-
dc.subject.keywordClinical Competence-
dc.subject.keywordErgonomics*-
dc.subject.keywordLaparoscopy/instrumentation*-
dc.subject.keywordMagnetics/instrumentation*-
dc.subject.keywordModels, Animal-
dc.subject.keywordNephrectomy/instrumentation*-
dc.subject.keywordNephrectomy/methods*-
dc.subject.keywordPhysicians-
dc.subject.keywordSus scrofa/surgery*-
dc.subject.keywordTime Factors-
dc.subject.keywordWorkload*-
dc.contributor.alternativeNameHan, Woong Kyu-
dc.contributor.affiliatedAuthorHan, Woong Kyu-
dc.rights.accessRightsnot free-
dc.citation.volume27-
dc.citation.number4-
dc.citation.startPage490-
dc.citation.endPage496-
dc.identifier.bibliographicCitationJOURNAL OF ENDOUROLOGY, Vol.27(4) : 490-496, 2013-
dc.identifier.rimsid29157-
dc.type.rimsART-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Urology (비뇨의학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.