3 807

Cited 6 times in

Safety and Efficacy of the NiTi Shape Memory Compression Anastomosis Ring (CAR/ColonRing) for End-to-End Compression Anastomosis in Anterior Resection or Low Anterior Resection.

Authors
 Jeonghyun Kang  ;  Min Geun Park  ;  Hyuk Hur  ;  Byung Soh Min  ;  Kang Young Lee  ;  Nam Kyu Kim 
Citation
 SURGICAL INNOVATION, Vol.20(2) : 164-170, 2013 
Journal Title
SURGICAL INNOVATION
ISSN
 1553-3506 
Issue Date
2013
MeSH
Adult ; Aged ; Aged, 80 and over ; Anastomosis, Surgical/adverse effects ; Anastomosis, Surgical/instrumentation* ; Anastomosis, Surgical/methods ; Chi-Square Distribution ; Colorectal Neoplasms/surgery* ; Female ; Humans ; Male ; Middle Aged ; Perioperative Period/methods ; Prospective Studies ; Republic of Korea
Keywords
compression anastomosis ; colorectal cancer ; ColonRing ; anterior resection ; low anterior resection
Abstract
PURPOSE:
Compression anastomoses may represent an improvement over traditional hand-sewn or stapled techniques. This prospective exploratory study aimed to assess the efficacy and complication rates in patients undergoing anterior resection (AR) or low anterior resection (LAR) anastomosed with a novel end-to-end compression anastomosis ring, the ColonRing.
METHODS:
In all, 20 patients (13 male) undergoing AR or LAR were enrolled to be anastomosed using the NiTi Shape Memory End-to-End Compression Anastomosis Ring (NiTi Medical Technologies Ltd, Netanya, Israel). Demographic, intraoperative, and postoperative data were collected.
RESULTS:
Patients underwent AR (11/20) or LAR using laparoscopy (75%), robotic (10%) surgery, or an open laparotomy (15%) approach, with a median anastomotic level of 14.5 cm (range, 4-25 cm). Defunctioning loop ileostomies were formed in 6 patients for low anastomoses. Surgeons rated the ColonRing device as either easy or very easy to use. One patient developed an anastomotic leakage in the early postoperative period; there were no late postoperative complications. Mean time to passage of first flatus and commencement of oral fluids was 2.5 days and 3.2 days, respectively. Average hospital stay was 12.6 days (range, 8-23 days). Finally, the device was expelled on average 15.3 days postoperatively without difficulty.
CONCLUSIONS:
This is the first study reporting results in a significant number of LAR patients and the first reported experience from South Korea; it shows that the compression technique is surgically feasible, easy to use, and without significant complication rates. A large randomized controlled trial is warranted to investigate the benefits of the ColonRing over traditional stapling techniques.
Full Text
http://sri.sagepub.com/content/20/2/164.long
DOI
10.1177/1553350612449073
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Surgery (외과학교실) > 1. Journal Papers
Yonsei Authors
Kang, Jeonghyun(강정현) ORCID logo https://orcid.org/0000-0001-7311-6053
Kim, Nam Kyu(김남규) ORCID logo https://orcid.org/0000-0003-0639-5632
Min, Byung Soh(민병소) ORCID logo https://orcid.org/0000-0003-0180-8565
Lee, Kang Young(이강영)
Hur, Hyuk(허혁) ORCID logo https://orcid.org/0000-0002-9864-7229
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/86601
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links