0 25

Cited 0 times in

Cited 0 times in

Acoustofluidic Focusing for High-Throughput and Sensitive Analysis of Shape-Encoded Hydrogel Microparticles in Multiplex Immunoassay

DC Field Value Language
dc.contributor.authorChoi, Jun Hee-
dc.contributor.authorShin, Dong Min-
dc.contributor.authorKim, Jiwoo-
dc.contributor.authorJung, Min Ju-
dc.contributor.authorLee, Min-Ho-
dc.contributor.authorOta, Sadao-
dc.contributor.authorKim, Min Jung-
dc.contributor.authorLee, Sangwook-
dc.contributor.authorBong, Ki Wan-
dc.date.accessioned2026-07-10T07:43:58Z-
dc.date.available2026-07-10T07:43:58Z-
dc.date.created2026-06-30-
dc.date.issued2026-04-
dc.identifier.issn2379-3694-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/212939-
dc.description.abstractShape-encoded hydrogel microparticles (SHMPs) offer robust sensitivity and multiplexing capacity in immunoassays. However, their analysis has conventionally required labor-intensive imaging-based methods. Although flow-through analysis has been explored as an alternative approach, its throughput and sensitivity remain limited. In this study, we developed a high-throughput and highly sensitive multiplex immunoassay platform by integrating SHMPs with acoustofluidic focusing. Acoustofluidic focusing is a powerful technique that enables high-throughput analysis owing to its capability to densely align micro-objects. Since hydrogel materials are challenging to accurately align by acoustofluidic focusing, we optimized the flow rate as well as the amplitude and frequency of acoustic standing waves to achieve precise and dense particle alignment. The precise alignment of SHMPs in microchannels allowed reliable code recognition and fluorescence signal detection. Also, densely aligned SHMPs offered an 8-fold higher analysis throughput than previously studied flow-through methods, even at low flow rates. The synergistic effects of sufficient dwell time provided by acoustofluidic focusing at low flow rates and the high sensitivity of SHMPs achieved a 61.5-fold enhancement in the detection limit compared to commercial devices using flow-through analysis. The feasibility of multiplex detection was further validated through spike-in experiments, yielding recovery rates within 100 +/- 20% for all four protein targets. Finally, we assayed cytokines in clinical samples from drug allergy and healthy groups and successfully identified significant differences in the cytokine levels.-
dc.languageEnglish-
dc.publisherAmerican Chemical Society-
dc.relation.isPartOfACS SENSORS-
dc.relation.isPartOfACS SENSORS-
dc.subject.MESHAcoustics*-
dc.subject.MESHHigh-Throughput Screening Assays* / methods-
dc.subject.MESHHumans-
dc.subject.MESHHydrogels* / chemistry-
dc.subject.MESHImmunoassay / instrumentation-
dc.subject.MESHImmunoassay / methods-
dc.subject.MESHMicrofluidic Analytical Techniques* / instrumentation-
dc.subject.MESHMicrofluidic Analytical Techniques* / methods-
dc.subject.MESHMicrospheres-
dc.titleAcoustofluidic Focusing for High-Throughput and Sensitive Analysis of Shape-Encoded Hydrogel Microparticles in Multiplex Immunoassay-
dc.typeArticle-
dc.contributor.googleauthorChoi, Jun Hee-
dc.contributor.googleauthorShin, Dong Min-
dc.contributor.googleauthorKim, Jiwoo-
dc.contributor.googleauthorJung, Min Ju-
dc.contributor.googleauthorLee, Min-Ho-
dc.contributor.googleauthorOta, Sadao-
dc.contributor.googleauthorKim, Min Jung-
dc.contributor.googleauthorLee, Sangwook-
dc.contributor.googleauthorBong, Ki Wan-
dc.identifier.doi10.1021/acssensors.5c03744-
dc.relation.journalcodeJ03609-
dc.identifier.pmid41984547-
dc.identifier.urlhttps://pubs.acs.org/doi/10.1021/acssensors.5c03744-
dc.subject.keywordacoustofluidic focusing-
dc.subject.keywordshape-encoding-
dc.subject.keywordhydrogel microparticles-
dc.subject.keywordmultiplex immunoassay-
dc.subject.keywordcytokine profiling-
dc.contributor.affiliatedAuthorKim, Min Jung-
dc.identifier.scopusid2-s2.0-105036286186-
dc.identifier.wosid001779233500001-
dc.citation.volume11-
dc.citation.number5-
dc.citation.startPage3686-
dc.citation.endPage3697-
dc.identifier.bibliographicCitationACS SENSORS, Vol.11(5) : 3686-3697, 2026-04-
dc.identifier.rimsid94471-
dc.type.rimsART-
dc.description.journalClass1-
dc.description.journalClass1-
dc.subject.keywordAuthoracoustofluidic focusing-
dc.subject.keywordAuthorshape-encoding-
dc.subject.keywordAuthorhydrogel microparticles-
dc.subject.keywordAuthormultiplex immunoassay-
dc.subject.keywordAuthorcytokine profiling-
dc.subject.keywordPlusFLOW-CYTOMETRY-
dc.subject.keywordPlusCYTOKINES-
dc.subject.keywordPlusGUIDE-
dc.type.docTypeArticle-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalWebOfScienceCategoryChemistry, Multidisciplinary-
dc.relation.journalWebOfScienceCategoryChemistry, Analytical-
dc.relation.journalWebOfScienceCategoryNanoscience & Nanotechnology-
dc.relation.journalResearchAreaChemistry-
dc.relation.journalResearchAreaScience & Technology - Other Topics-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Pediatrics (소아과학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.