0 17

Cited 0 times in

Cited 0 times in

Urine-Based Noninvasive Detection of Prostate Cancer Using Human Olfactory Receptor-Embedded Nanodiscs

DC Field Value Language
dc.contributor.authorYoo, Jin-
dc.contributor.authorKim, Yerin-
dc.contributor.authorKang, Ku-
dc.contributor.authorAhn, Young Jin-
dc.contributor.authorBang, Sungun-
dc.contributor.authorKoo, Kyo Chul-
dc.contributor.authorPark, Tai Hyun-
dc.date.accessioned2026-06-18T07:25:19Z-
dc.date.available2026-06-18T07:25:19Z-
dc.date.created2026-06-08-
dc.date.issued2026-05-
dc.identifier.issn2379-3694-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/212748-
dc.description.abstractThe diagnosis of prostate cancer (PCa) is limited by the low specificity of prostate-specific antigen (PSA) testing, which contributes to overdiagnosis and patient exposure to unnecessary invasive prostate biopsies. Here, we report a urine-based diagnostic platform that combines a six-member human olfactory receptor-embedded nanodisc (OR-ND) sensor array with fluorescence sensing and machine learning to detect PCa-associated volatile organic compounds (VOCs). Six ORs were reconstituted into lipid nanodiscs and evaluated using urine samples from a strictly curated subcohort of 40 PCa patients and 33 healthy controls (n = 73) to establish baseline sensor responsiveness. Subsequently, to ensure diagnostic robustness, machine learning classifiers were developed and cross-validated using an expanded data set of 290 samples, achieving an accuracy of 0.890 and an AUC of 0.964. Analysis of the full receptor data set revealed distinct response patterns, and statistical screening with correlation filtering identified OR2W1, OR51E1, and OR51E2 as the most informative features. Using these selected receptors, a random forest classifier achieved an accuracy of 0.890 and an AUC of 0.964, demonstrating high sensitivity and specificity. OR response patterns showed a closer association with Gleason score than with serum PSA levels, indicating that urinary VOC signatures capture tumor-related metabolic information complementary to conventional biomarkers. These results demonstrate that an OR-ND sensor array coupled with machine learning enables accurate and noninvasive detection and classification of PCa from urine samples. Our study provides a modular framework extensible to other VOC-associated diseases.-
dc.languageEnglish-
dc.publisherAmerican Chemical Society-
dc.relation.isPartOfACS SENSORS-
dc.relation.isPartOfACS SENSORS-
dc.subject.MESHBiosensing Techniques* / methods-
dc.subject.MESHHumans-
dc.subject.MESHMachine Learning-
dc.subject.MESHMale-
dc.subject.MESHMiddle Aged-
dc.subject.MESHNanostructures* / chemistry-
dc.subject.MESHProstatic Neoplasms* / diagnosis-
dc.subject.MESHProstatic Neoplasms* / urine-
dc.subject.MESHReceptors, Odorant* / chemistry-
dc.subject.MESHReceptors, Odorant* / metabolism-
dc.subject.MESHVolatile Organic Compounds* / urine-
dc.titleUrine-Based Noninvasive Detection of Prostate Cancer Using Human Olfactory Receptor-Embedded Nanodiscs-
dc.typeArticle-
dc.contributor.googleauthorYoo, Jin-
dc.contributor.googleauthorKim, Yerin-
dc.contributor.googleauthorKang, Ku-
dc.contributor.googleauthorAhn, Young Jin-
dc.contributor.googleauthorBang, Sungun-
dc.contributor.googleauthorKoo, Kyo Chul-
dc.contributor.googleauthorPark, Tai Hyun-
dc.identifier.doi10.1021/acssensors.6c00794-
dc.relation.journalcodeJ03609-
dc.identifier.pmid42047253-
dc.identifier.urlhttps://pubs.acs.org/doi/10.1021/acssensors.6c00794-
dc.subject.keywordprostate cancer-
dc.subject.keywordurine biomarker-
dc.subject.keywordolfactory receptor-
dc.subject.keywordnanodisc-
dc.subject.keywordfluorescence quenching analysis-
dc.subject.keywordrandom forest-
dc.contributor.affiliatedAuthorAhn, Young Jin-
dc.contributor.affiliatedAuthorBang, Sungun-
dc.contributor.affiliatedAuthorKoo, Kyo Chul-
dc.identifier.scopusid2-s2.0-105039748622-
dc.identifier.wosid001752596600001-
dc.citation.volume11-
dc.citation.number5-
dc.citation.startPage4121-
dc.citation.endPage4131-
dc.identifier.bibliographicCitationACS SENSORS, Vol.11(5) : 4121-4131, 2026-05-
dc.identifier.rimsid93288-
dc.type.rimsART-
dc.description.journalClass1-
dc.description.journalClass1-
dc.subject.keywordAuthorprostate cancer-
dc.subject.keywordAuthorurine biomarker-
dc.subject.keywordAuthorolfactory receptor-
dc.subject.keywordAuthornanodisc-
dc.subject.keywordAuthorfluorescence quenching analysis-
dc.subject.keywordAuthorrandom forest-
dc.subject.keywordPlusDOGS-
dc.subject.keywordPlusBIOPSY-
dc.subject.keywordPlusSYSTEM-
dc.type.docTypeArticle; Early Access-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalWebOfScienceCategoryChemistry, Multidisciplinary-
dc.relation.journalWebOfScienceCategoryChemistry, Analytical-
dc.relation.journalWebOfScienceCategoryNanoscience & Nanotechnology-
dc.relation.journalResearchAreaChemistry-
dc.relation.journalResearchAreaScience & Technology - Other Topics-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Urology (비뇨의학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.