0 8

Cited 0 times in

Cited 0 times in

An Electric Source Imaging Approach Demonstrating Diagnostic Value of Nasopharyngeal Electrodes in Temporal Lobe Epilepsy

DC Field Value Language
dc.contributor.authorChoi, Yun-ho-
dc.contributor.authorJang, Taeik-
dc.contributor.authorYim, Soo-hwan-
dc.contributor.authorHeo, Kyoung-
dc.date.accessioned2026-01-30T07:03:10Z-
dc.date.available2026-01-30T07:03:10Z-
dc.date.created2026-01-30-
dc.date.issued2025-10-
dc.identifier.issn0736-0258-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/210400-
dc.description.abstractPurpose: – To investigate the different regions covered by nasopharyngeal (NPEs) and anterior temporal (anterior temporal electrodes [ATEs]) electrodes in assessing temporal lobe epilepsy, to overcome the limitations of the 10 to 20 electroencephalography (EEG) in diagnosing the basal and mesial temporal regions.Methods: – EEG data from 229 patients diagnosed with temporal lobe epilepsy were simultaneously analyzed with attached NPEs and ATEs. In case of discrepancies in EEG interpretation, a consensus interpretation was reached among three epilepsy experts. Spike detection was conducted using the Curry9 program for secondary analysis of electric source localization, with source location performed using standard brain MRI data.Results: – In total, 2, 721 interictal epileptiform discharges (IEDs) from 175 patients were analyzed. Of these, 734 IEDs from 48 patients were detected exclusively with NPEs, while 1, 987 IEDs from 127 patients were detected simultaneously by both NPEs and the standard international 10 to 20 electrodes system supplemented with ATEs, respectively. The former IEDs exhibited clustering dipoles in the basal and mesial temporal regions, while the latter were localized solely to the frontotemporal and lateral temporal regions.Conclusions: – Nasopharyngeals can identify IEDs in the mesial and basal temporal region that cannot be detected by ATEs. Nasopharyngeals offer additional diagnostic value in regions not confirmed by the existing 10 to 20 EEG electrode system, including those covered by ATE. © 2025 The Author(s). Published by Wolters Kluwer Health, Inc. on behalf of the American Clinical Neurophysiology Society.-
dc.languageEnglish-
dc.publisherLippincott Williams & Wilkins-
dc.relation.isPartOfJournal of Clinical Neurophysiology-
dc.relation.isPartOfJOURNAL OF CLINICAL NEUROPHYSIOLOGY-
dc.titleAn Electric Source Imaging Approach Demonstrating Diagnostic Value of Nasopharyngeal Electrodes in Temporal Lobe Epilepsy-
dc.typeArticle-
dc.contributor.googleauthorChoi, Yun-ho-
dc.contributor.googleauthorJang, Taeik-
dc.contributor.googleauthorYim, Soo-hwan-
dc.contributor.googleauthorHeo, Kyoung-
dc.identifier.doi10.1097/WNP.0000000000001213-
dc.relation.journalcodeJ04646-
dc.identifier.eissn1537-1603-
dc.identifier.pmid41042968-
dc.identifier.urlhttps://journals.lww.com/clinicalneurophys/fulltext/9900/an_electric_source_imaging_approach_demonstrating.265.aspx-
dc.subject.keywordEEG-
dc.subject.keywordElectric source imaging-
dc.subject.keywordNasopharyngeal electrode-
dc.subject.keywordTemporal lobe epilepsy-
dc.contributor.affiliatedAuthorHeo, Kyoung-
dc.identifier.scopusid2-s2.0-105027756328-
dc.identifier.bibliographicCitationJournal of Clinical Neurophysiology, 2025-10-
dc.identifier.rimsid91434-
dc.type.rimsART-
dc.description.journalClass1-
dc.description.journalClass1-
dc.subject.keywordAuthorEEG-
dc.subject.keywordAuthorElectric source imaging-
dc.subject.keywordAuthorNasopharyngeal electrode-
dc.subject.keywordAuthorTemporal lobe epilepsy-
dc.type.docTypeArticle-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Neurology (신경과학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.