4 15

Cited 0 times in

Cited 0 times in

Efficiency and geometric fidelity of library-selected anatomical prefabricated abutments and stock abutments relative to custom CAD-CAM abutments in posterior implant restorations

Authors
 Shin, Jihoon  ;  Sun, Minji  ;  Kim, Jee-Hwan  ;  Kim, Jaeyoung 
Citation
 JOURNAL OF ADVANCED PROSTHODONTICS, Vol.17(6) : 392-405, 2025-12 
Journal Title
JOURNAL OF ADVANCED PROSTHODONTICS
ISSN
 2005-7806 
Issue Date
2025-12
Keywords
Digital workflow ; Implant abutment ; Clinical efficiency ; Margin-level fidelity ; Sector-based deviation analysis
Abstract
PURPOSE. This study evaluated the clinical efficiency and geometric fidelity of the library-selected anatomical prefabricated abutments (LAPA) compared with custom abutments (CA) and stock abutments (SA) by using a novel sector-based deviation analysis (SBDA) method. MATERIALS AND METHODS. Two posterior single-implant cases, the mandibular left first molar and right second premolar, were selected forin vitro analysis. Twenty-four dental professionals (15 prosthodontic residents and 9 board-certified prosthodontists) performed three tasks: CA design, LAPA selection, and SA selection. The recorded time required for CA design and LAPA selection was compared. Overall geometric conformity was assessed using in-tolerance analysis (+/- 0.50 mm, +/- 0.70 mm), and margin-level fidelity was evaluated by sector-based and vector-based deviation analyses. The Wilcoxon signed-rank test was used to evaluate the clinical efficiency and geometric fidelity at a significance level of alpha = 0.05. RESULTS. LAPA required significantly less design time than the custom abutment (CA) (P < .001). Both LAPA and SA showed high overall conformity to CA within clinically acceptable limits. Sector-and vector-based analyses demonstrated that LAPA more closely replicated CA margin positions than SA, indicating superior morphological consistency with greater time efficiency. CONCLUSION. Within the limitations of this in vitro study, the library-selected anatomical prefabricated abutment showed a balanced performance between clinical efficiency and morphological fidelity.
Files in This Item:
91090.pdf Download
DOI
10.4047/jap.2025.17.6.392
Appears in Collections:
2. College of Dentistry (치과대학) > Dept. of Prosthodontics (보철과학교실) > 1. Journal Papers
Yonsei Authors
Kim, Jae-Young(김재영)
Kim, Jee Hwan(김지환) ORCID logo https://orcid.org/0000-0002-0872-4906
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/210240
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links