2 11

Cited 15 times in

Cited 0 times in

Differential evolution method to find optimal location of a single-element transducer for transcranial focused ultrasound therapy

Authors
 Park, Tae Young  ;  Kim, Hyo-Jin  ;  Park, So Hui  ;  Chang, Won Seok  ;  Kim, Hyungmin  ;  Yoon, Kyungho 
Citation
 COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, Vol.219, 2022-06 
Article Number
 106777 
Journal Title
COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE
ISSN
 0169-2607 
Issue Date
2022-06
MeSH
Acoustics ; Brain / diagnostic imaging ; Humans ; Skull* / diagnostic imaging ; Transducers* ; Water
Keywords
Transcranial focused ultrasound ; Single-element transducer ; Guidance system ; Numerical simulation ; Optimization ; Differential evolution
Abstract
Background and objective: Focused ultrasound (FUS) has been receiving growing attention as a noninvasive brain stimulation tool because of its superior spatial specificity and depth penetrability. However, the large mismatch of acoustic properties between the skull and water can disrupt and shift the acoustic focus in the brain. In this paper, we present a numerical method to find the optimal location of a single-element FUS transducer, which creates focus on the target region.Methods: The score function, representing the superposition of acoustic waves according to the relative phase difference and transmissibility, was defined based on time-reversal invariance of acoustic waves and depending on the spatial location of the transducer. The optimal location of the transducer was then determined using a differential evolution algorithm. To assess the proposed method, we conducted a forward simulation and compared the resulting focal location to the desired target point. We also performed experimental validation by measuring the acoustic pressure field through an ex vivo human skull in a water tank. Results: The numerical results indicated that the score function had a positive proportional relationship with the acoustic pressure at the target. Moreover, for the optimized transducer location, both the numerical and experimental results showed that the normalized acoustic pressure at the target was higher than 0.9.Conclusions: In this study, we developed an optimization method to place a single-element transducer that effectively transmits acoustic energy to the targeted region in the brain. Our numerical and experimental results demonstrate that the proposed method can provide an optimal transducer location for safe and efficient FUS treatment.(c) 2022 The Author(s). Published by Elsevier B.V. This is an open access article under the CC BY license ( http://creativecommons.org/licenses/by/4.0/ )
Files in This Item:
90989.pdf Download
DOI
10.1016/j.cmpb.2022.106777
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Neurosurgery (신경외과학교실) > 1. Journal Papers
Yonsei Authors
Chang, Won Seok(장원석) ORCID logo https://orcid.org/0000-0003-3145-4016
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/210017
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links