0 22

Cited 0 times in

Cited 0 times in

Feasibility of biodegradable polymer everolimus-eluting stent overexpansion: the SYNOVER study

Authors
 Lee, Seung Hun  ;  Lee, Yong-Kyu  ;  Ahn, Joon Ho  ;  Kim, Yongcheol  ;  Park, Seongho  ;  Joo, Donghyeon  ;  Cho, Kyung Hoo  ;  Kim, Min Chul  ;  Sim, Doo Sun  ;  Kim, Ju Han  ;  Ahn, Youngkeun  ;  Hong, Young Joon 
Citation
 CORONARY ARTERY DISEASE, Vol.36(7) : 604-609, 2025-11 
Journal Title
CORONARY ARTERY DISEASE
ISSN
 0954-6928 
Issue Date
2025-11
MeSH
Absorbable Implants ; Aged ; Cardiovascular Agents* / administration & dosage ; Cardiovascular Agents* / adverse effects ; Coronary Artery Disease* / diagnostic imaging ; Coronary Artery Disease* / mortality ; Coronary Artery Disease* / therapy ; Coronary Vessels / diagnostic imaging ; Coronary Vessels / surgery ; Drug-Eluting Stents* ; Everolimus* / administration & dosage ; Feasibility Studies ; Female ; Humans ; Male ; Middle Aged ; Percutaneous Coronary Intervention* / adverse effects ; Percutaneous Coronary Intervention* / instrumentation ; Polymers ; Prosthesis Design ; Time Factors ; Tomography, Optical Coherence ; Treatment Outcome
Keywords
acute coronary syndrome ; large coronary artery ; optical coherence tomography ; percutaneous coronary intervention
Abstract
BackgroundDespite advancements in percutaneous coronary intervention (PCI), stent-related complications continue to occur, emphasizing the necessity for stent optimization. This study employed optical coherence tomography (OCT) to investigate the safety and efficacy of overexpanding the biodegradable polymer everolimus-eluting stent (SYNERGY; Boston Scientific, Marlborough, Massachusetts, USA) stent in large coronary arteries.MethodsThis single-center observational study enrolled patients with ischemic heart disease requiring stent placement in large coronary arteries (>= 4.5 mm). The patients underwent PCI guided by OCT using SYNERGY stents, incorporating postdilation techniques to enhance expansion. Stent parameters were evaluated through OCT imaging. The primary endpoints focused on the maximum stent diameter and the maximum percentage of overexpansion. Secondary clinical outcomes, including death, myocardial infarction (MI), revascularization, stent thrombosis, cerebrovascular accidents (CVAs), and heart failure readmissions, were monitored with follow-ups at 1, 6, and 12 months, as well as annually thereafter.ResultsA total of 12 patients (8427 struts) were analyzed after successful PCI. OCT imaging showed adequate stent expansion, maximum stent diameter was 4.5 +/- 0.2 mm, with a maximum expansion of 113.2 +/- 4.1%), with no definite stent fractures or major edge dissections. During follow-up, one patient experienced an MI, but no stent thrombosis, target lesion revascularization, CVA, or death were reported.ConclusionApplication of OCT-guided PCI with SYNERGY stents is safe and effective for treating large coronary arteries. It facilitates optimal stent expansion and yields favorable long-term outcomes. These results advocate for an expanded application of OCT-guided PCI in complex anatomical situations, showcasing the performance of SYNERGY stents in cases of excess expansion.
Full Text
https://journals.lww.com/coronary-artery/fulltext/2025/11000/feasibility_of_biodegradable_polymer.8
DOI
10.1097/MCA.0000000000001529
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Internal Medicine (내과학교실) > 1. Journal Papers
Yonsei Authors
Kim, Yongcheol(김용철) ORCID logo https://orcid.org/0000-0001-5568-4161
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/209952
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links