Cited 0 times in 
Cited 0 times in 
Comparative evaluation of volume and helical four-dimensional computed tomography using canon system
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Kim, Changhwan | - |
| dc.contributor.author | Lee, Eunho | - |
| dc.contributor.author | Yu, Jae Hong | - |
| dc.contributor.author | Kim, Hojae | - |
| dc.contributor.author | Park, Seyjoon | - |
| dc.contributor.author | Han, Soorim | - |
| dc.contributor.author | Kim, Tae Ho | - |
| dc.contributor.author | Han, Min Cheol | - |
| dc.contributor.author | Hong, Chae-seon | - |
| dc.contributor.author | Kim, Jin Sung | - |
| dc.date.accessioned | 2025-12-02T06:53:38Z | - |
| dc.date.available | 2025-12-02T06:53:38Z | - |
| dc.date.created | 2025-12-11 | - |
| dc.date.issued | 2025-11 | - |
| dc.identifier.issn | 1526-9914 | - |
| dc.identifier.uri | https://ir.ymlib.yonsei.ac.kr/handle/22282913/209392 | - |
| dc.description.abstract | Background Four-dimensional computed tomography (4DCT) is an advanced imaging technique designed to capture anatomical motion over time, enabling more accurate evaluation of tumor and organ motion owing to respiration, while minimizing motion-related artifacts. 4DCT employs two primary scanning modes-volume (cine) mode and helical mode-each with distinct clinical implications. A comprehensive evaluation of both approaches is therefore essential prior to clinical implementation.Purpose This study aimed to compare volume and helical 4DCT scan modes in terms of image quality, dimensional accuracy, and positional accuracy for respiratory-gated radiotherapy.Methods 4DCT imaging was conducted using a Canon Aquilion ONE Prism CT scanner integrated with an Anzai respiratory gating system. The two scan modes were assessed under identical imaging parameters, with differences arising only from their respective acquisition protocols. Phantom experiments were conducted using a motion phantom to simulate normal, rapid, and irregular respiratory patterns. Image quality, dimensional accuracy, and positional accuracy were quantitatively evaluated. Additionally, a retrospective analysis was conducted on clinical 4DCT datasets (n = 10), including lung, liver, and pancreatic cancers.Results Volume mode demonstrated superior dose efficiency and dimensional consistency, preserving stable object volumes across respiratory phases, particularly under rapid motion conditions. Helical mode achieved higher positional accuracy and improved temporal resolution for motion tracking, but with a greater imaging dose. These findings were consistent with the clinical datasets, wherein volume mode reduced dimensional errors and helical mode provided more accurate motion representation.Conclusions Both volume and helical 4DCT modes offer distinct advantages depending on clinical objectives. Volume mode is better suited for applications requiring high spatial accuracy and reduced radiation exposure, while helical mode is preferable for precise tracking of respiratory motion owing to its superior temporal resolution. Careful selection of the scan mode and system settings is essential for optimizing respiratory-gated radiotherapy planning. | - |
| dc.description.statementOfResponsibility | open | - |
| dc.format | application/pdf | - |
| dc.language | English | - |
| dc.publisher | Wiley | - |
| dc.relation.isPartOf | JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS | - |
| dc.relation.isPartOf | JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS | - |
| dc.rights | CC BY-NC-ND 2.0 KR | - |
| dc.subject.MESH | Artifacts | - |
| dc.subject.MESH | Four-Dimensional Computed Tomography* / instrumentation | - |
| dc.subject.MESH | Four-Dimensional Computed Tomography* / methods | - |
| dc.subject.MESH | Humans | - |
| dc.subject.MESH | Image Processing, Computer-Assisted* / methods | - |
| dc.subject.MESH | Liver Neoplasms* / diagnostic imaging | - |
| dc.subject.MESH | Liver Neoplasms* / radiotherapy | - |
| dc.subject.MESH | Lung Neoplasms* / diagnostic imaging | - |
| dc.subject.MESH | Lung Neoplasms* / radiotherapy | - |
| dc.subject.MESH | Pancreatic Neoplasms* / diagnostic imaging | - |
| dc.subject.MESH | Pancreatic Neoplasms* / radiotherapy | - |
| dc.subject.MESH | Phantoms, Imaging* | - |
| dc.subject.MESH | Radiotherapy Dosage | - |
| dc.subject.MESH | Radiotherapy Planning, Computer-Assisted* / methods | - |
| dc.subject.MESH | Radiotherapy, Intensity-Modulated / methods | - |
| dc.subject.MESH | Respiration | - |
| dc.subject.MESH | Respiratory-Gated Imaging Techniques* / methods | - |
| dc.subject.MESH | Retrospective Studies | - |
| dc.subject.MESH | Tomography, Spiral Computed* / methods | - |
| dc.title | Comparative evaluation of volume and helical four-dimensional computed tomography using canon system | - |
| dc.type | Article | - |
| dc.contributor.college | College of Medicine (의과대학) | - |
| dc.contributor.department | Dept. of Radiation Oncology (방사선종양학교실) | - |
| dc.contributor.googleauthor | Kim, Changhwan | - |
| dc.contributor.googleauthor | Lee, Eunho | - |
| dc.contributor.googleauthor | Yu, Jae Hong | - |
| dc.contributor.googleauthor | Kim, Hojae | - |
| dc.contributor.googleauthor | Park, Seyjoon | - |
| dc.contributor.googleauthor | Han, Soorim | - |
| dc.contributor.googleauthor | Kim, Tae Ho | - |
| dc.contributor.googleauthor | Han, Min Cheol | - |
| dc.contributor.googleauthor | Hong, Chae-seon | - |
| dc.contributor.googleauthor | Kim, Jin Sung | - |
| dc.identifier.doi | 10.1002/acm2.70351 | - |
| dc.relation.journalcode | J03009 | - |
| dc.identifier.eissn | 1526-9914 | - |
| dc.identifier.pmid | 41239171 | - |
| dc.subject.keyword | 4DCT | - |
| dc.subject.keyword | helical scan mode | - |
| dc.subject.keyword | respiratory-gated radiotherapy | - |
| dc.subject.keyword | volume scan mode | - |
| dc.contributor.alternativeName | Kim, Jinsung | - |
| dc.contributor.affiliatedAuthor | Kim, Changhwan | - |
| dc.contributor.affiliatedAuthor | Han, Soorim | - |
| dc.contributor.affiliatedAuthor | Kim, Tae Ho | - |
| dc.contributor.affiliatedAuthor | Han, Min Cheol | - |
| dc.contributor.affiliatedAuthor | Hong, Chae-seon | - |
| dc.contributor.affiliatedAuthor | Kim, Jin Sung | - |
| dc.identifier.scopusid | 2-s2.0-105021811452 | - |
| dc.identifier.wosid | 001614659000001 | - |
| dc.citation.volume | 26 | - |
| dc.citation.number | 11 | - |
| dc.identifier.bibliographicCitation | JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, Vol.26(11), 2025-11 | - |
| dc.identifier.rimsid | 90246 | - |
| dc.type.rims | ART | - |
| dc.description.journalClass | 1 | - |
| dc.description.journalClass | 1 | - |
| dc.subject.keywordAuthor | 4DCT | - |
| dc.subject.keywordAuthor | helical scan mode | - |
| dc.subject.keywordAuthor | respiratory-gated radiotherapy | - |
| dc.subject.keywordAuthor | volume scan mode | - |
| dc.subject.keywordPlus | RESPIRATORY MOTION | - |
| dc.subject.keywordPlus | RADIOTHERAPY | - |
| dc.subject.keywordPlus | MANAGEMENT | - |
| dc.subject.keywordPlus | 4DCT | - |
| dc.type.docType | Article | - |
| dc.description.isOpenAccess | Y | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.relation.journalWebOfScienceCategory | Radiology, Nuclear Medicine & Medical Imaging | - |
| dc.relation.journalResearchArea | Radiology, Nuclear Medicine & Medical Imaging | - |
| dc.identifier.articleno | e70351 | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.