One-year clinical and radiologic outcomes of Surpass Evolve flow diverter for large unruptured intracranial aneurysms
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Han, Hyun J. | - |
| dc.contributor.author | Chung, Joonho | - |
| dc.contributor.author | Jang, Chang K. | - |
| dc.contributor.author | Kim, Jung-Jae | - |
| dc.contributor.author | Park, Keun Y. | - |
| dc.contributor.author | Kim, Yong B. | - |
| dc.date.accessioned | 2025-12-02T06:44:16Z | - |
| dc.date.available | 2025-12-02T06:44:16Z | - |
| dc.date.created | 2024-04-18 | - |
| dc.date.issued | 2025-04 | - |
| dc.identifier.issn | 0390-5616 | - |
| dc.identifier.uri | https://ir.ymlib.yonsei.ac.kr/handle/22282913/209325 | - |
| dc.description.abstract | BACKGROUND: Surpass Evolve Flow Diverter (SE-FD; Stryker Neurovascular, Kalamazoo, MI, USA) was launched in 2019 as a new generation FD of Surpass Streamline. The aim of this study was to report the effectiveness and safety of SE-FD insertion for unruptured intracranial aneurysm at one-year follow-up.METHODS: Between November 2019 and October 2021, a total of 106 patients with 108 aneurysms were treated with FD in single institution. Of these, SE-FD insertion was performed in 40 patients with 41 aneurysms. At one-year follow-up, clinical and angiographic outcomes were retrospectively evaluated from electronic medical record and aneurysm database.RESULTS: There were 12 male and 28 female patients (mean age 59.1 years, 95% CI: 55.3-62.9). Fusiform aneurysm dissection was 46.3% (19/41). Mean maximum aneurysm diameter was 13.2 mm (SD 5.53), and 34.1% (14/41) of aneurysms were 15 mm or bigger. Among 41 aneurysms, complex aneurysm (recurred, thrombosed, or branch artery-incorporated) was accounted for 41.5% (17/41). All procedures were successfully conducted with 7.3% (3/41) of procedure-related complications. At one-year follow-up (N.=40), neurologic morbidity was noted in 2 cases (5.0%; both with modified Rankin Scale [mRS] 1) without any mortality. At one-year follow-up (N.=41), radiologic outcomes were adequate occlusion in 33 (80.5%) and complete occlusion in 29 (70.7%). There was no retreatment in our cohort.CONCLUSIONS: Surpass Evolve Flow Diverter seemed to be safe and effective for the treatment of dissecting/fusiform or complex aneurysms at one-year follow-up. However, further study is needed to evaluate long term results. | - |
| dc.description.statementOfResponsibility | restriction | - |
| dc.language | English | - |
| dc.publisher | Minerva Medica | - |
| dc.relation.isPartOf | JOURNAL OF NEUROSURGICAL SCIENCES | - |
| dc.relation.isPartOf | JOURNAL OF NEUROSURGICAL SCIENCES | - |
| dc.rights | CC BY-NC-ND 2.0 KR | - |
| dc.title | One-year clinical and radiologic outcomes of Surpass Evolve flow diverter for large unruptured intracranial aneurysms | - |
| dc.type | Article | - |
| dc.contributor.college | College of Medicine (의과대학) | - |
| dc.contributor.department | Dept. of Neurosurgery (신경외과학교실) | - |
| dc.contributor.googleauthor | Han, Hyun J. | - |
| dc.contributor.googleauthor | Chung, Joonho | - |
| dc.contributor.googleauthor | Jang, Chang K. | - |
| dc.contributor.googleauthor | Kim, Jung-Jae | - |
| dc.contributor.googleauthor | Park, Keun Y. | - |
| dc.contributor.googleauthor | Kim, Yong B. | - |
| dc.identifier.doi | 10.23736/S0390-5616.23.06161-1 | - |
| dc.relation.journalcode | J04675 | - |
| dc.identifier.eissn | 1827-1855 | - |
| dc.identifier.pmid | 38127302 | - |
| dc.subject.keyword | Intracranial aneurysm | - |
| dc.subject.keyword | Endovascular procedures | - |
| dc.subject.keyword | Treatment outcome | - |
| dc.contributor.alternativeName | Kim, Yong Bae | - |
| dc.contributor.affiliatedAuthor | Han, Hyun J. | - |
| dc.contributor.affiliatedAuthor | Chung, Joonho | - |
| dc.contributor.affiliatedAuthor | Jang, Chang K. | - |
| dc.contributor.affiliatedAuthor | Kim, Jung-Jae | - |
| dc.contributor.affiliatedAuthor | Park, Keun Y. | - |
| dc.contributor.affiliatedAuthor | Kim, Yong B. | - |
| dc.identifier.scopusid | 2-s2.0-105004889702 | - |
| dc.identifier.wosid | 001146224500001 | - |
| dc.citation.volume | 69 | - |
| dc.citation.number | 2 | - |
| dc.citation.startPage | 167 | - |
| dc.citation.endPage | 173 | - |
| dc.identifier.bibliographicCitation | JOURNAL OF NEUROSURGICAL SCIENCES, Vol.69(2) : 167-173, 2025-04 | - |
| dc.identifier.rimsid | 83352 | - |
| dc.type.rims | ART | - |
| dc.description.journalClass | 1 | - |
| dc.description.journalClass | 1 | - |
| dc.subject.keywordAuthor | Intracranial aneurysm | - |
| dc.subject.keywordAuthor | Endovascular procedures | - |
| dc.subject.keywordAuthor | Treatment outcome | - |
| dc.subject.keywordPlus | PIPELINE | - |
| dc.type.docType | Article | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.relation.journalWebOfScienceCategory | Clinical Neurology | - |
| dc.relation.journalWebOfScienceCategory | Surgery | - |
| dc.relation.journalResearchArea | Neurosciences & Neurology | - |
| dc.relation.journalResearchArea | Surgery | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.