Cited 0 times in 
Cited 0 times in 
Can Reference Materials Prepared Following CLSI C37-A Be Utilized Without Commutability Assessment? Perspectives Based on Lipid Measurements
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | 이상국 | - |
| dc.date.accessioned | 2025-12-02T06:40:35Z | - |
| dc.date.available | 2025-12-02T06:40:35Z | - |
| dc.date.issued | 2025-11 | - |
| dc.identifier.issn | 2234-3806 | - |
| dc.identifier.uri | https://ir.ymlib.yonsei.ac.kr/handle/22282913/209297 | - |
| dc.description.abstract | Background: Ensuring reference material (RM) commutability is crucial for evaluating measurement traceability in order to standardize laboratory tests. However, commutability assessment is not routinely performed. We assessed whether RMs prepared following CLSI C37-A guidelines could be used without assessing commutability by evaluating their commutability for four lipid measurements using the International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) and CLSI EP14 protocols. Methods: We analyzed total cholesterol (TC), triglycerides (TGs), high-density lipoprotein cholesterol (HDL-C), and low-density lipoprotein cholesterol (LDL-C) in frozen sera from 20 individuals and 11 RMs, prepared by the Korea Disease Control and Prevention Agency-Laboratory Standardization Project (per CLSI C37-A), using six routine measurement procedures (MPs). Regression equations and 95% prediction intervals derived from single-donor sera were analyzed following CLSI EP14. The IFCC protocol was used to assess differences in inter-MP biases between RM and clinical samples. The effect of the TG concentration on commutability was evaluated by analyzing biases between MP results and reference procedure-assigned values. Results: RMs were commutable for most MP pairs for TC and TG. Commutability for HDL-C and LDL-C varied across RMs, with RM10 and RM11 showing higher TG levels (2.38 and 2.95 mmol/L, respectively) and lower commutability. Increased bias percentages from assigned values were observed for RMs with higher TG levels. Conclusions: RMs prepared per CLSI C37-A were commutable with most MP pairs for TC and TG. Elevated TG levels affected HDL-C and LDL-C commutability, highlighting the need to consider TG concentrations during RM preparation and assess commutability to standardize laboratory tests. | - |
| dc.description.statementOfResponsibility | open | - |
| dc.language | English | - |
| dc.publisher | Korean Society for Laboratory Medicine | - |
| dc.relation.isPartOf | ANNALS OF LABORATORY MEDICINE | - |
| dc.rights | CC BY-NC-ND 2.0 KR | - |
| dc.subject.MESH | Cholesterol / blood | - |
| dc.subject.MESH | Cholesterol / standards | - |
| dc.subject.MESH | Cholesterol, HDL / blood | - |
| dc.subject.MESH | Cholesterol, HDL / standards | - |
| dc.subject.MESH | Cholesterol, LDL / blood | - |
| dc.subject.MESH | Cholesterol, LDL / standards | - |
| dc.subject.MESH | Humans | - |
| dc.subject.MESH | Lipids* / blood | - |
| dc.subject.MESH | Reference Standards | - |
| dc.subject.MESH | Republic of Korea | - |
| dc.subject.MESH | Triglycerides / blood | - |
| dc.subject.MESH | Triglycerides / standards | - |
| dc.title | Can Reference Materials Prepared Following CLSI C37-A Be Utilized Without Commutability Assessment? Perspectives Based on Lipid Measurements | - |
| dc.type | Article | - |
| dc.contributor.college | College of Medicine (의과대학) | - |
| dc.contributor.department | Dept. of Laboratory Medicine (진단검사의학교실) | - |
| dc.contributor.googleauthor | Jong Do Seo | - |
| dc.contributor.googleauthor | Gye Cheol Kwon | - |
| dc.contributor.googleauthor | Jeong-Ho Kim | - |
| dc.contributor.googleauthor | Sang-Guk Lee | - |
| dc.contributor.googleauthor | Junghan Song | - |
| dc.contributor.googleauthor | Pil-Whan Park | - |
| dc.contributor.googleauthor | Dongheui An | - |
| dc.contributor.googleauthor | Qute Choi | - |
| dc.contributor.googleauthor | Chan-Ik Cho | - |
| dc.contributor.googleauthor | Sollip Kim | - |
| dc.contributor.googleauthor | Yeo-Min Yun | - |
| dc.identifier.doi | 10.3343/alm.2025.0010 | - |
| dc.contributor.localId | A02810 | - |
| dc.relation.journalcode | J00164 | - |
| dc.identifier.eissn | 2234-3814 | - |
| dc.identifier.pmid | 40899267 | - |
| dc.subject.keyword | Cholesterol | - |
| dc.subject.keyword | Commutability | - |
| dc.subject.keyword | External quality assessment material | - |
| dc.subject.keyword | Lipids | - |
| dc.subject.keyword | Reference material | - |
| dc.subject.keyword | Triglycerides | - |
| dc.contributor.alternativeName | Lee, Sang Guk | - |
| dc.contributor.affiliatedAuthor | 이상국 | - |
| dc.citation.volume | 45 | - |
| dc.citation.number | 6 | - |
| dc.citation.startPage | 562 | - |
| dc.citation.endPage | 573 | - |
| dc.identifier.bibliographicCitation | ANNALS OF LABORATORY MEDICINE, Vol.45(6) : 562-573, 2025-11 | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.