7 28

Cited 1 times in

Cited 0 times in

A Prospective Randomized Trial Comparing 2 Different Paclitaxel-Coated Balloons in De Novo Coronary Artery Disease

DC Field Value Language
dc.contributor.authorShin, Eun-Seok-
dc.contributor.authorPark, Yongwhi-
dc.contributor.authorLee, Jong-Young-
dc.contributor.authorHer, Ae-Young-
dc.contributor.authorChon, Min-Ku-
dc.contributor.authorKim, Sunwon-
dc.contributor.authorRha, Seung-Woon-
dc.contributor.authorOh, Gyu Chul-
dc.contributor.authorCho, Deok-Kyu-
dc.contributor.authorKim, Bitna-
dc.contributor.authorBae, Jang-Whan-
dc.date.accessioned2025-11-10T07:37:40Z-
dc.date.available2025-11-10T07:37:40Z-
dc.date.created2025-08-19-
dc.date.issued2025-01-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/208580-
dc.description.abstractBACKGROUND The Genoss paclitaxel-coated balloon (PCB) is a novel PCB with shellac and vitamin E as excipients, enhancing drug delivery to the target lesion and minimizing restenosis. OBJECTIVES This study aimed to compare quantitative coronary angiographic outcomes at 6 months after treatment of de novo coronary artery disease (CAD) with 2 different types of PCBs. METHODS This prospective, multicenter, noninferiority trial randomized 204 patients with chronic coronary syndrome or stabilized acute coronary syndrome to treatment with the shellac and vitamin E-based PCB or the reference PCB (SeQuent Please NEO) in a 1:1 ratio. The primary endpoint was noninferiority for the 6-month angiographic in-lesion late lumen loss. RESULTS The 6-month in-lesion late lumen loss was 0.06 f 0.38 mm with shellac and vitamin E-based PCB vs 0.09 f 0.36 mm with reference PCB. The 1-sided 97.5% upper confidence limit of the difference was 0.08 mm, which was lower than the noninferiority limit of 0.15 mm, achieving noninferiority (P for noninferiority = 0.001). There was comparable late lumen enlargement (44.7% vs 42.7%; P = 0.903) and binary restenosis rates (3.2% vs 6.7%; P = 0.442) following treatment with shellac and vitamin E-based PCB and reference PCB, respectively. Both PCBs had similar 12-month rates of target vessel failure (3.0% in shellac and vitamin E-based PCB vs 4.3% in reference PCB; P = 0.921). CONCLUSIONS The Genoss PCB, formulated with shellac and vitamin E as excipients, demonstrated angiographic outcomes comparable to a clinically proven PCB in the treatment of de novo CAD. (Compare the Safety and Efficacy of Genoss (R) DCB and SeQuent (R) Please NEO in Coronary De Novo Lesions; NCT05096442) (JACC Asia. 2025;5:15-24) (c) 2025 The Authors. Published by Elsevier on behalf of the American College of Cardiology Foundation. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).-
dc.formatapplication/pdf-
dc.language영어-
dc.publisherELSEVIER-
dc.relation.isPartOfJACC-ASIA-
dc.titleA Prospective Randomized Trial Comparing 2 Different Paclitaxel-Coated Balloons in De Novo Coronary Artery Disease-
dc.typeArticle-
dc.contributor.googleauthorShin, Eun-Seok-
dc.contributor.googleauthorPark, Yongwhi-
dc.contributor.googleauthorLee, Jong-Young-
dc.contributor.googleauthorHer, Ae-Young-
dc.contributor.googleauthorChon, Min-Ku-
dc.contributor.googleauthorKim, Sunwon-
dc.contributor.googleauthorRha, Seung-Woon-
dc.contributor.googleauthorOh, Gyu Chul-
dc.contributor.googleauthorCho, Deok-Kyu-
dc.contributor.googleauthorKim, Bitna-
dc.contributor.googleauthorBae, Jang-Whan-
dc.identifier.doi10.1016/j.jacasi.2024.10.028-
dc.identifier.pmid39886190-
dc.subject.keyworddrug-coated balloon-
dc.subject.keywordoutcome-
dc.subject.keywordpaclitaxel-
dc.subject.keywordpercutaneous coronary intervention-
dc.subject.keywordrandomized controlled trial-
dc.contributor.affiliatedAuthorCho, Deok-Kyu-
dc.identifier.scopusid2-s2.0-85213007239-
dc.identifier.wosid001490427900003-
dc.citation.volume5-
dc.citation.number1-
dc.citation.startPage15-
dc.citation.endPage24-
dc.identifier.bibliographicCitationJACC-ASIA, Vol.5(1) : 15-24, 2025-01-
dc.identifier.rimsid88695-
dc.type.rimsART-
dc.description.journalClass1-
dc.description.journalClass1-
dc.subject.keywordAuthordrug-coated balloon-
dc.subject.keywordAuthoroutcome-
dc.subject.keywordAuthorpaclitaxel-
dc.subject.keywordAuthorpercutaneous coronary intervention-
dc.subject.keywordAuthorrandomized controlled trial-
dc.subject.keywordPlusDRUG-
dc.subject.keywordPlusEFFICACY-
dc.subject.keywordPlusSAFETY-
dc.type.docTypeArticle-
dc.description.isOpenAccessY-
dc.description.journalRegisteredClassscopus-
dc.relation.journalWebOfScienceCategoryCardiac & Cardiovascular Systems-
dc.relation.journalResearchAreaCardiovascular System & Cardiology-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Internal Medicine (내과학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.