Cited 0 times in 
Cited 0 times in 
Influence of remnant cholesterol on direct LDL and HDL cholesterol measurement accuracy
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Kwon, Soon Sung | - |
| dc.contributor.author | Jang, Hanmil | - |
| dc.contributor.author | Rim, John Hoon | - |
| dc.contributor.author | Cho, Jooyoung | - |
| dc.contributor.author | Seo, Jong Do | - |
| dc.contributor.author | Yun, Yeo-Min | - |
| dc.contributor.author | Park, Yun Mi | - |
| dc.contributor.author | Kwon, Gye Cheol | - |
| dc.contributor.author | Cho, Chan-Ik | - |
| dc.contributor.author | Lee, Sang-Guk | - |
| dc.contributor.author | Lim, Jong-Baeck | - |
| dc.date.accessioned | 2025-11-06T06:18:26Z | - |
| dc.date.available | 2025-11-06T06:18:26Z | - |
| dc.date.created | 2025-10-30 | - |
| dc.date.issued | 2025-09 | - |
| dc.identifier.issn | 1434-6621 | - |
| dc.identifier.uri | https://ir.ymlib.yonsei.ac.kr/handle/22282913/208369 | - |
| dc.description.abstract | Objectives: Identifying the potential sources of bias in the direct measurement of low-density lipoprotein cholesterol (LDL-C) and high-density lipoprotein cholesterol (HDL-C) is important. In this study, we aimed to investigate the effect of remnant cholesterol on LDL-C and HDL-C levels measured using homogenous methods. Methods: We obtained 41 commutable frozen serum samples and measured LDL-C and HDL-C levels. Eight measurement systems were used, and the degree of bias was obtained by comparing with the values obtained using the reference methods. Correlations among remnant cholesterol/LDL-C, remnant cholesterol/HDL-C, and bias were analyzed using Spearman's analysis. Results: In all eight systems, samples with a positive bias >4 % had lower LDL-C levels and higher remnant cholesterol levels, as measured by the reference methods, compared to those with a bias <= 4 %. A significant correlation between remnant cholesterol/LDL-C and a positive bias of LDL-C was observed in six of the eight systems evaluated. For HDL-C bias, three systems showed a positive correlation, and three systems showed a negative correlation. In some systems, LDL-C bias was higher in samples with remnant cholesterol/LDL-C >= 0.25 than in those with remnant cholesterol/LDL-C <0.25. Conclusions:<bold> </bold>Remnant cholesterol has a potential effect on direct LDL-C and HDL-C measurements, which has been observed when several measurement systems are used. For these systems, manufacturers should improve the methods to reduce the interference of remnant cholesterol. | - |
| dc.language | English | - |
| dc.publisher | Walter De Gruyter | - |
| dc.relation.isPartOf | CLINICAL CHEMISTRY AND LABORATORY MEDICINE | - |
| dc.relation.isPartOf | CLINICAL CHEMISTRY AND LABORATORY MEDICINE | - |
| dc.title | Influence of remnant cholesterol on direct LDL and HDL cholesterol measurement accuracy | - |
| dc.type | Article | - |
| dc.contributor.googleauthor | Kwon, Soon Sung | - |
| dc.contributor.googleauthor | Jang, Hanmil | - |
| dc.contributor.googleauthor | Rim, John Hoon | - |
| dc.contributor.googleauthor | Cho, Jooyoung | - |
| dc.contributor.googleauthor | Seo, Jong Do | - |
| dc.contributor.googleauthor | Yun, Yeo-Min | - |
| dc.contributor.googleauthor | Park, Yun Mi | - |
| dc.contributor.googleauthor | Kwon, Gye Cheol | - |
| dc.contributor.googleauthor | Cho, Chan-Ik | - |
| dc.contributor.googleauthor | Lee, Sang-Guk | - |
| dc.contributor.googleauthor | Lim, Jong-Baeck | - |
| dc.identifier.doi | 10.1515/cclm-2025-0593 | - |
| dc.relation.journalcode | J00567 | - |
| dc.identifier.eissn | 1437-4331 | - |
| dc.identifier.pmid | 40968781 | - |
| dc.subject.keyword | cardiovascular disease | - |
| dc.subject.keyword | high-density lipoprotein cholesterol | - |
| dc.subject.keyword | lipids | - |
| dc.subject.keyword | low-density lipoprotein cholesterol | - |
| dc.subject.keyword | remnant cholesterol | - |
| dc.contributor.affiliatedAuthor | Kwon, Soon Sung | - |
| dc.contributor.affiliatedAuthor | Jang, Hanmil | - |
| dc.contributor.affiliatedAuthor | Rim, John Hoon | - |
| dc.contributor.affiliatedAuthor | Lee, Sang-Guk | - |
| dc.contributor.affiliatedAuthor | Lim, Jong-Baeck | - |
| dc.identifier.scopusid | 2-s2.0-105016764978 | - |
| dc.identifier.wosid | 001575403000001 | - |
| dc.identifier.bibliographicCitation | CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2025-09 | - |
| dc.identifier.rimsid | 90036 | - |
| dc.type.rims | ART | - |
| dc.description.journalClass | 1 | - |
| dc.description.journalClass | 1 | - |
| dc.subject.keywordAuthor | cardiovascular disease | - |
| dc.subject.keywordAuthor | high-density lipoprotein cholesterol | - |
| dc.subject.keywordAuthor | lipids | - |
| dc.subject.keywordAuthor | low-density lipoprotein cholesterol | - |
| dc.subject.keywordAuthor | remnant cholesterol | - |
| dc.subject.keywordPlus | DENSITY-LIPOPROTEIN CHOLESTEROL | - |
| dc.subject.keywordPlus | ULTRACENTRIFUGATION | - |
| dc.subject.keywordPlus | INTERFERENCE | - |
| dc.subject.keywordPlus | ASSAYS | - |
| dc.type.docType | Article; Early Access | - |
| dc.description.isOpenAccess | Y | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.relation.journalWebOfScienceCategory | Medical Laboratory Technology | - |
| dc.relation.journalResearchArea | Medical Laboratory Technology | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.