1 6

Cited 0 times in

Cited 0 times in

Influence of remnant cholesterol on direct LDL and HDL cholesterol measurement accuracy

DC Field Value Language
dc.contributor.authorKwon, Soon Sung-
dc.contributor.authorJang, Hanmil-
dc.contributor.authorRim, John Hoon-
dc.contributor.authorCho, Jooyoung-
dc.contributor.authorSeo, Jong Do-
dc.contributor.authorYun, Yeo-Min-
dc.contributor.authorPark, Yun Mi-
dc.contributor.authorKwon, Gye Cheol-
dc.contributor.authorCho, Chan-Ik-
dc.contributor.authorLee, Sang-Guk-
dc.contributor.authorLim, Jong-Baeck-
dc.date.accessioned2025-11-06T06:18:26Z-
dc.date.available2025-11-06T06:18:26Z-
dc.date.created2025-10-30-
dc.date.issued2025-09-
dc.identifier.issn1434-6621-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/208369-
dc.description.abstractObjectives: Identifying the potential sources of bias in the direct measurement of low-density lipoprotein cholesterol (LDL-C) and high-density lipoprotein cholesterol (HDL-C) is important. In this study, we aimed to investigate the effect of remnant cholesterol on LDL-C and HDL-C levels measured using homogenous methods. Methods: We obtained 41 commutable frozen serum samples and measured LDL-C and HDL-C levels. Eight measurement systems were used, and the degree of bias was obtained by comparing with the values obtained using the reference methods. Correlations among remnant cholesterol/LDL-C, remnant cholesterol/HDL-C, and bias were analyzed using Spearman&apos;s analysis. Results: In all eight systems, samples with a positive bias >4 % had lower LDL-C levels and higher remnant cholesterol levels, as measured by the reference methods, compared to those with a bias <= 4 %. A significant correlation between remnant cholesterol/LDL-C and a positive bias of LDL-C was observed in six of the eight systems evaluated. For HDL-C bias, three systems showed a positive correlation, and three systems showed a negative correlation. In some systems, LDL-C bias was higher in samples with remnant cholesterol/LDL-C >= 0.25 than in those with remnant cholesterol/LDL-C <0.25. Conclusions:<bold> </bold>Remnant cholesterol has a potential effect on direct LDL-C and HDL-C measurements, which has been observed when several measurement systems are used. For these systems, manufacturers should improve the methods to reduce the interference of remnant cholesterol.-
dc.languageEnglish-
dc.publisherWalter De Gruyter-
dc.relation.isPartOfCLINICAL CHEMISTRY AND LABORATORY MEDICINE-
dc.relation.isPartOfCLINICAL CHEMISTRY AND LABORATORY MEDICINE-
dc.titleInfluence of remnant cholesterol on direct LDL and HDL cholesterol measurement accuracy-
dc.typeArticle-
dc.contributor.googleauthorKwon, Soon Sung-
dc.contributor.googleauthorJang, Hanmil-
dc.contributor.googleauthorRim, John Hoon-
dc.contributor.googleauthorCho, Jooyoung-
dc.contributor.googleauthorSeo, Jong Do-
dc.contributor.googleauthorYun, Yeo-Min-
dc.contributor.googleauthorPark, Yun Mi-
dc.contributor.googleauthorKwon, Gye Cheol-
dc.contributor.googleauthorCho, Chan-Ik-
dc.contributor.googleauthorLee, Sang-Guk-
dc.contributor.googleauthorLim, Jong-Baeck-
dc.identifier.doi10.1515/cclm-2025-0593-
dc.relation.journalcodeJ00567-
dc.identifier.eissn1437-4331-
dc.identifier.pmid40968781-
dc.subject.keywordcardiovascular disease-
dc.subject.keywordhigh-density lipoprotein cholesterol-
dc.subject.keywordlipids-
dc.subject.keywordlow-density lipoprotein cholesterol-
dc.subject.keywordremnant cholesterol-
dc.contributor.affiliatedAuthorKwon, Soon Sung-
dc.contributor.affiliatedAuthorJang, Hanmil-
dc.contributor.affiliatedAuthorRim, John Hoon-
dc.contributor.affiliatedAuthorLee, Sang-Guk-
dc.contributor.affiliatedAuthorLim, Jong-Baeck-
dc.identifier.scopusid2-s2.0-105016764978-
dc.identifier.wosid001575403000001-
dc.identifier.bibliographicCitationCLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2025-09-
dc.identifier.rimsid90036-
dc.type.rimsART-
dc.description.journalClass1-
dc.description.journalClass1-
dc.subject.keywordAuthorcardiovascular disease-
dc.subject.keywordAuthorhigh-density lipoprotein cholesterol-
dc.subject.keywordAuthorlipids-
dc.subject.keywordAuthorlow-density lipoprotein cholesterol-
dc.subject.keywordAuthorremnant cholesterol-
dc.subject.keywordPlusDENSITY-LIPOPROTEIN CHOLESTEROL-
dc.subject.keywordPlusULTRACENTRIFUGATION-
dc.subject.keywordPlusINTERFERENCE-
dc.subject.keywordPlusASSAYS-
dc.type.docTypeArticle; Early Access-
dc.description.isOpenAccessY-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalWebOfScienceCategoryMedical Laboratory Technology-
dc.relation.journalResearchAreaMedical Laboratory Technology-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Laboratory Medicine (진단검사의학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.