Cited 0 times in
디지털 정보의 통합과 하악 움직임 트래킹을 이용한 고정성 전악보철 회복 증례
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 김지환 | - |
dc.contributor.author | 박지만 | - |
dc.date.accessioned | 2025-09-02T08:20:19Z | - |
dc.date.available | 2025-09-02T08:20:19Z | - |
dc.date.issued | 2025-07 | - |
dc.identifier.issn | 0301-2875 | - |
dc.identifier.uri | https://ir.ymlib.yonsei.ac.kr/handle/22282913/207265 | - |
dc.description.abstract | This case report details the diagnostic design process for a 72-year-old woman with an edentulous mandible, which was achieved by creating a virtual patient. The 3D data files, which included facial, dental, and cone beam computed tomography (CBCT) scans, were then aligned using dental computer-aided design (CAD) software. A provisional restoration was fabricated using milling and 3D printing technologies to reflect the ideal diagnostic design. Following this, four implants were placed in the mandible, and an intraoral scan method was used to fabricate fixed provisional implant restorations. Finally, definitive full fixed-type prostheses were fabricated using the double scan technique and jaw motion tracking. | - |
dc.description.statementOfResponsibility | open | - |
dc.language | Korean, English | - |
dc.publisher | Korean Academy of Prosthodontics) | - |
dc.relation.isPartOf | Journal of Korean Academy of Prosthodontics(대한치과보철학회지) | - |
dc.rights | CC BY-NC-ND 2.0 KR | - |
dc.title | 디지털 정보의 통합과 하악 움직임 트래킹을 이용한 고정성 전악보철 회복 증례 | - |
dc.title.alternative | Application of multi-source digital information integration and Jaw motion tracking for complete arch implant-supported prosthesis: a case report | - |
dc.type | Article | - |
dc.contributor.college | College of Dentistry (치과대학) | - |
dc.contributor.department | Dept. of Prosthodontics (보철과학교실) | - |
dc.contributor.googleauthor | 윤명아 | - |
dc.contributor.googleauthor | 박지만 | - |
dc.contributor.googleauthor | 김지환 | - |
dc.contributor.localId | A01006 | - |
dc.contributor.localId | A05595 | - |
dc.relation.journalcode | J01493 | - |
dc.identifier.eissn | 2005-3789 | - |
dc.subject.keyword | CAD-CAM, Digital workflow, Double scan technique, Facial scan, Jaw motion tracking | - |
dc.contributor.alternativeName | Kim, Jee Hwan | - |
dc.contributor.affiliatedAuthor | 김지환 | - |
dc.contributor.affiliatedAuthor | 박지만 | - |
dc.citation.volume | 63 | - |
dc.citation.number | 3 | - |
dc.citation.startPage | 246 | - |
dc.citation.endPage | 253 | - |
dc.identifier.bibliographicCitation | Journal of Korean Academy of Prosthodontics (대한치과보철학회지), Vol.63(3) : 246-253, 2025-07 | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.