Cited 0 times in
Interference haptic stimulation and consistent quantitative tactility in transparent electrotactile screen with pressure-sensitive transistors
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 정현호 | - |
dc.date.accessioned | 2025-04-17T08:11:42Z | - |
dc.date.available | 2025-04-17T08:11:42Z | - |
dc.date.issued | 2024-08 | - |
dc.identifier.uri | https://ir.ymlib.yonsei.ac.kr/handle/22282913/204517 | - |
dc.description.abstract | Integrating tactile feedback through haptic interfaces enhances experiences in virtual and augmented reality. However, electrotactile systems, which stimulate mechanoreceptors directly, often yield inconsistent tactile results due to variations in pressure between the device and the finger. In this study, we present the integration of a transparent electrotactile screen with pressure-sensitive transistors, ensuring highly consistent quantitative haptic sensations. These transistors effectively calibrate tactile variations caused by touch pressure. Additionally, we explore remote-distance tactile stimulations achieved through the interference of electromagnetic waves. We validated tactile perception using somatosensory evoked potentials, monitoring the somatosensory cortex response. Our haptic screen can stimulate diverse electrotactile sensations and demonstrate various tactile patterns, including Morse code and Braille, when integrated with portable smart devices, delivering a more immersive experience. Furthermore, interference of electric fields allows haptic stimulation to facilitate diverse stimulus positioning at lower current densities, extending the reach beyond direct contact with electrodes of our screen. | - |
dc.description.statementOfResponsibility | open | - |
dc.language | English | - |
dc.publisher | Nature Pub. Group | - |
dc.relation.isPartOf | NATURE COMMUNICATIONS | - |
dc.rights | CC BY-NC-ND 2.0 KR | - |
dc.subject.MESH | Adult | - |
dc.subject.MESH | Evoked Potentials, Somatosensory* / physiology | - |
dc.subject.MESH | Feedback, Sensory / physiology | - |
dc.subject.MESH | Female | - |
dc.subject.MESH | Fingers / physiology | - |
dc.subject.MESH | Humans | - |
dc.subject.MESH | Male | - |
dc.subject.MESH | Mechanoreceptors / physiology | - |
dc.subject.MESH | Pressure | - |
dc.subject.MESH | Somatosensory Cortex / physiology | - |
dc.subject.MESH | Touch Perception* / physiology | - |
dc.subject.MESH | Touch* / physiology | - |
dc.subject.MESH | Transistors, Electronic* | - |
dc.subject.MESH | Young Adult | - |
dc.title | Interference haptic stimulation and consistent quantitative tactility in transparent electrotactile screen with pressure-sensitive transistors | - |
dc.type | Article | - |
dc.contributor.college | College of Medicine (의과대학) | - |
dc.contributor.department | Dept. of Neurosurgery (신경외과학교실) | - |
dc.contributor.googleauthor | Kyeonghee Lim | - |
dc.contributor.googleauthor | Jakyoung Lee | - |
dc.contributor.googleauthor | Sumin Kim | - |
dc.contributor.googleauthor | Myoungjae Oh | - |
dc.contributor.googleauthor | Chin Su Koh | - |
dc.contributor.googleauthor | Hunkyu Seo | - |
dc.contributor.googleauthor | Yeon-Mi Hong | - |
dc.contributor.googleauthor | Won Gi Chung | - |
dc.contributor.googleauthor | Jiuk Jang | - |
dc.contributor.googleauthor | Jung Ah Lim | - |
dc.contributor.googleauthor | Hyun Ho Jung | - |
dc.contributor.googleauthor | Jang-Ung Park | - |
dc.identifier.doi | 10.1038/s41467-024-51593-2 | - |
dc.contributor.localId | A03775 | - |
dc.relation.journalcode | J02293 | - |
dc.identifier.eissn | 2041-1723 | - |
dc.identifier.pmid | 39168999 | - |
dc.contributor.alternativeName | Jung, Hyun Ho | - |
dc.contributor.affiliatedAuthor | 정현호 | - |
dc.citation.volume | 15 | - |
dc.citation.number | 1 | - |
dc.citation.startPage | 7147 | - |
dc.identifier.bibliographicCitation | NATURE COMMUNICATIONS, Vol.15(1) : 7147, 2024-08 | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.