dc.description.abstractMedical linear accelerators with an energy of 8 MV or higher are radiated owing to photonuclear reactions and neutron capture reactions. It is necessary to quantitatively evaluate the concentration of radioactive isotopes when replacing or disposing them. HPGe detectors are commonly used to identify isotopes and measure radioactivity. However, because the detection efficiency is generally calibrated using a standard material with a density of 1.0 g/cm3, a self-absorption effect occurs if the density of the measured material is high. In this study, self-absorption correction factors were calculated for tungsten, lead, copper, and SUS-303, which are the main materials of medical linear accelerator head parts, for each gamma-ray energy using MCNP 6.2 code. The self-absorption effect was more pronounced as the energy of the emitted gamma rays decreased and the density of the measured materials increased. These correction factors were applied to the radioactivity measurements of the in-built and portable HPGe detectors. Furthermore, compared to the surface dose rate measured by the survey meter, the accuracy of the measurements of radioactivity improved by an average of 124.31 and 100.53 % for in-built and portable HPGe detectors, respectively. The results showed a good agreement, with an average difference of 3.70 and 5.24 %.-
dc.description.statementOfResponsibilityrestriction-
dc.languageEnglish-
dc.publisherKorea Nuclear Society-
dc.relation.isPartOfNUCLEAR ENGINEERING AND TECHNOLOGY-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.titleImprovement of accuracy in radioactivity assessment of medical linear accelerator through self-absorption correction in HPGe detector-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Radiation Oncology (방사선종양학교실)-
dc.contributor.googleauthorSuah Yu-
dc.contributor.googleauthorNa Hye Kwon-
dc.contributor.googleauthorSang-Rok Kim-
dc.contributor.googleauthorYoung Jin Won-
dc.contributor.googleauthorKum Bae Kim-
dc.contributor.googleauthorSe Byeong Lee-
dc.contributor.googleauthorCheol Ha Baek-
dc.contributor.googleauthorSang Hyoun Choi-
dc.identifier.doi10.1016/j.net.2024.01.042-
dc.relation.journalcodeJ03972-
dc.identifier.urlhttps://www.sciencedirect.com/science/article/pii/S1738573324000445-
dc.subject.keywordHPGe detector-
dc.subject.keywordSelf-absorption effect-
dc.subject.keywordMedical linear accelerator-
dc.subject.keywordMCNP code-
dc.citation.volume56-
dc.citation.number6-
dc.citation.startPage2317-
dc.citation.endPage2323-
dc.identifier.bibliographicCitationNUCLEAR ENGINEERING AND TECHNOLOGY, Vol.56(6) : 2317-2323, 2024-06-