Cited 0 times in

Femoral Neck Fractures Treated by Closed Reduction and Internal Fixation with the Double Fluoroscope Technique: A Preliminary Study

DC Field Value Language
dc.date.accessioned2025-03-13T16:40:08Z-
dc.date.available2025-03-13T16:40:08Z-
dc.date.issued2024-02-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/204067-
dc.description.abstractBackground: Fractures of the femur require significant radiation exposure during operations using fluoroscopy (C-arm), posing a high risk of radiation exposure to the medical staff and patients. To address this concern, in this study, we investigated the efficacy of using two fluoroscopy machines simultaneously. Methods: We categorized 30 patients with femoral neck fracture (FNF) into single and double C-arm groups. The operation and radiation exposure times during a closed reduction and internal fixation operation were investigated to evaluate whether the operation and radiation exposure times were effectively audited when the operation was performed using a double C-arm. Results: The total operation times were 93.21 ± 20.70 min and 66.69 ± 13.97 min for the single and double C-arm groups, respectively. Additionally, the total radiation times were 100.43 ± 24.59 s and 83.06 ± 19.53 s for the single and double C-arm groups, respectively. Operation and radiation exposure times in the two groups showed statistically significant differences (p < 0.05). Conclusion: The use of double C-arm in FNF can reduce operation and radiation exposure times. Hence, using the double C-arm in surgical treatment could reduce the risk of radiation exposure to medical staff and patients.-
dc.description.statementOfResponsibilityopen-
dc.languageEnglish-
dc.publisherMDPI AG-
dc.relation.isPartOfJOURNAL OF CLINICAL MEDICINE-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.titleFemoral Neck Fractures Treated by Closed Reduction and Internal Fixation with the Double Fluoroscope Technique: A Preliminary Study-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Orthopedic Surgery (정형외과학교실)-
dc.contributor.googleauthorHyun Hee Lee-
dc.contributor.googleauthorKyung-Yil Kang-
dc.contributor.googleauthorSeung-Yong Sung-
dc.contributor.googleauthorSoo-Bin Lee-
dc.contributor.googleauthorSang-Hee Kim-
dc.contributor.googleauthorSu-Il Jung-
dc.contributor.googleauthorDong Hyuk Shin-
dc.contributor.googleauthorByung Hak Oh-
dc.contributor.googleauthorDong-Sik Chae-
dc.identifier.doi10.3390/jcm13051418-
dc.relation.journalcodeJ03556-
dc.identifier.eissn2077-0383-
dc.identifier.pmid38592215-
dc.subject.keywordclosed reduction-
dc.subject.keyworddouble C-arm-
dc.subject.keywordfemoral neck fractures-
dc.subject.keywordinternal fixation-
dc.subject.keywordradiation exposure reduction-
dc.citation.volume13-
dc.citation.number5-
dc.citation.startPage1418-
dc.identifier.bibliographicCitationJOURNAL OF CLINICAL MEDICINE, Vol.13(5) : 1418, 2024-02-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Orthopedic Surgery (정형외과학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.