Cited 0 times in
Microbiome and Mycobiome Analyses of Continuous Positive Airway Pressure Devices
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 조형주 | - |
dc.date.accessioned | 2025-02-03T08:12:13Z | - |
dc.date.available | 2025-02-03T08:12:13Z | - |
dc.date.issued | 2024-11 | - |
dc.identifier.issn | 1976-8710 | - |
dc.identifier.uri | https://ir.ymlib.yonsei.ac.kr/handle/22282913/201590 | - |
dc.description.abstract | Objectives: Microorganisms are likely present in continuous positive airway pressure (CPAP) devices in daily use. Given the potential risk of infection among CPAP users, we aimed to compare the microbiomes of CPAP devices with those of nasal mucosa samples obtained from patients using these devices. Methods: We conducted a prospective cohort study at multiple tertiary medical institutions. Samples were collected from the tubes and filters of CPAP devices and the nasal mucosa of device users. Microbiomes and mycobiomes were analyzed using 16S ribosomal RNA and internal transcribed spacer region sequencing. The results were compared according to sampling site and usage duration for each patient. Results: Overall, 27 paired samples of human nasal mucosa and CPAP components were analyzed. Bacteria were detected in 7 of the 27 tubes (25.9%) and in 22 of the 27 filters (81.5%). Fungi were found in 2 tubes (7.4%) and 16 filters (59.3%). The most prevalent bacterial phyla across all samples were Actinobacteria and Firmicutes. Fungi were not detected in any nasal mucosa samples. However, fungi were identified in the CPAP filters and tubes, with the Basidiomycota and Ascomycota phyla predominating. No significant associations were identified according to sampling site or duration of CPAP use. Conclusion: Some bacteria or fungi are detectable in CPAP samples, even after a short period of CPAP usage. However, the association between respiratory infections and these microbiomes or mycobiomes was not investigated. Further research is required to clarify the risk posed by CPAP devices as a microbial contamination source. | - |
dc.description.statementOfResponsibility | open | - |
dc.language | English | - |
dc.publisher | Korean Society of Otorhinolaryngology--Head and Neck Surgery | - |
dc.relation.isPartOf | CLINICAL AND EXPERIMENTAL OTORHINOLARYNGOLOGY | - |
dc.rights | CC BY-NC-ND 2.0 KR | - |
dc.title | Microbiome and Mycobiome Analyses of Continuous Positive Airway Pressure Devices | - |
dc.type | Article | - |
dc.contributor.college | College of Medicine (의과대학) | - |
dc.contributor.department | Dept. of Otorhinolaryngology (이비인후과학교실) | - |
dc.contributor.googleauthor | Hyun Jin Min | - |
dc.contributor.googleauthor | Bo-Yun Choi | - |
dc.contributor.googleauthor | Woo Jun Sul | - |
dc.contributor.googleauthor | Hyung-Ju Cho | - |
dc.identifier.doi | 10.21053/ceo.2024.00167 | - |
dc.contributor.localId | A03936 | - |
dc.relation.journalcode | J00552 | - |
dc.identifier.eissn | 2005-0720 | - |
dc.identifier.pmid | 39134466 | - |
dc.subject.keyword | Continuous Positive Airway Pressure Device | - |
dc.subject.keyword | Microbiome | - |
dc.subject.keyword | Mycobiome | - |
dc.subject.keyword | Obstructive Sleep Apnea | - |
dc.contributor.alternativeName | Cho, Hyung Ju | - |
dc.contributor.affiliatedAuthor | 조형주 | - |
dc.citation.volume | 17 | - |
dc.citation.number | 4 | - |
dc.citation.startPage | 292 | - |
dc.citation.endPage | 301 | - |
dc.identifier.bibliographicCitation | CLINICAL AND EXPERIMENTAL OTORHINOLARYNGOLOGY, Vol.17(4) : 292-301, 2024-11 | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.