70 187

Cited 0 times in

Cited 26 times in

Enhanced dual-mode imaging: Superior photoacoustic and ultrasound endoscopy in live pigs using a transparent ultrasound transducer

DC Field Value Language
dc.contributor.authorKim, Jaewoo-
dc.contributor.authorHeo, Dasom-
dc.contributor.authorCho, Seonghee-
dc.contributor.authorHa, Mingyu-
dc.contributor.authorPark, Jeongwoo-
dc.contributor.authorAhn, Joongho-
dc.contributor.authorKim, Minsu-
dc.contributor.authorKim, Donggyu-
dc.contributor.authorJung, Da Hyun-
dc.contributor.authorKim, Hyung Ham-
dc.contributor.authorKim, Hee Man-
dc.contributor.authorKim, Chulhong-
dc.date.accessioned2025-02-03T08:03:04Z-
dc.date.available2025-02-03T08:03:04Z-
dc.date.created2025-03-20-
dc.date.issued2024-11-
dc.identifier.issn2375-2548-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/201536-
dc.description.abstractDual-mode photoacoustic/ultrasound endoscopy (ePAUS) is a promising tool for preclinical and clinical interventions. To be clinically useful, ePAUS must deliver high-performance ultrasound imaging comparable to commercial systems and maintain high photoacoustic imaging performance at long working distances. This requires a transducer with an intact physical aperture and coaxial alignment of acoustic and optical beams within the probe, a challenging integration task. We present a high-performance ePAUS probe with a miniaturized, optically transparent ultrasonic transducer (TUT) called ePAUS-TUT. The 1.8-mm-diameter probe, fitting into standard endoscopic channels, aligns acoustic and optical beams efficiently, achieving commercial-level ultrasound and high-resolution photoacoustic imaging over long distances. These imaging capabilities were validated through in vivo imaging of a rat's rectum and a pig's esophagus. The ePAUS-TUT system substantially enhances feasibility and potential for clinical applications.-
dc.description.statementOfResponsibilityopen-
dc.languageEnglish-
dc.publisherAmerican Association for the Advancement of Science-
dc.relation.isPartOfSCIENCE ADVANCES-
dc.relation.isPartOfSCIENCE ADVANCES-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.titleEnhanced dual-mode imaging: Superior photoacoustic and ultrasound endoscopy in live pigs using a transparent ultrasound transducer-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Internal Medicine (내과학교실)-
dc.contributor.googleauthorKim, Jaewoo-
dc.contributor.googleauthorHeo, Dasom-
dc.contributor.googleauthorCho, Seonghee-
dc.contributor.googleauthorHa, Mingyu-
dc.contributor.googleauthorPark, Jeongwoo-
dc.contributor.googleauthorAhn, Joongho-
dc.contributor.googleauthorKim, Minsu-
dc.contributor.googleauthorKim, Donggyu-
dc.contributor.googleauthorJung, Da Hyun-
dc.contributor.googleauthorKim, Hyung Ham-
dc.contributor.googleauthorKim, Hee Man-
dc.contributor.googleauthorKim, Chulhong-
dc.identifier.doi10.1126/sciadv.adq9960-
dc.relation.journalcodeJ03735-
dc.identifier.eissn2375-2548-
dc.identifier.pmid39576852-
dc.contributor.alternativeNameKim, Hee Man-
dc.contributor.affiliatedAuthorJung, Da Hyun-
dc.contributor.affiliatedAuthorKim, Hee Man-
dc.identifier.scopusid2-s2.0-85210295475-
dc.identifier.wosid001361919900006-
dc.citation.volume10-
dc.citation.number47-
dc.identifier.bibliographicCitationSCIENCE ADVANCES, Vol.10(47), 2024-11-
dc.identifier.rimsid85546-
dc.type.rimsART-
dc.description.journalClass1-
dc.description.journalClass1-
dc.subject.keywordPlusHIGH-RESOLUTION-
dc.type.docTypeArticle-
dc.description.isOpenAccessY-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalWebOfScienceCategoryMultidisciplinary Sciences-
dc.relation.journalResearchAreaScience & Technology - Other Topics-
dc.identifier.articlenoeadq9960-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Internal Medicine (내과학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.