26 103

Cited 0 times in

Cited 15 times in

Evaluation of left ventricular filling pressure by echocardiography in patients with atrial fibrillation

DC Field Value Language
dc.contributor.author하종원-
dc.contributor.author서지원-
dc.date.accessioned2024-12-06T03:25:21Z-
dc.date.available2024-12-06T03:25:21Z-
dc.date.issued2024-06-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/201087-
dc.description.abstractBackground: Echocardiography is widely used to evaluate left ventricular (LV) diastolic function in patients suspected of heart failure. For patients in sinus rhythm, a combination of several echocardiographic parameters can differentiate between normal and elevated LV filling pressure with good accuracy. However, there is no established echocardiographic approach for the evaluation of LV filling pressure in patients with atrial fibrillation. The objective of the present study was to determine if a combination of several echocardiographic and clinical parameters may be used to evaluate LV filling pressure in patients with atrial fibrillation. Results: In a multicentre study of 148 atrial fibrillation patients, several echocardiographic parameters were tested against invasively measured LV filling pressure as the reference method. No single parameter had sufficiently strong association with LV filling pressure to be recommended for clinical use. Based on univariate regression analysis in the present study, and evidence from existing literature, we developed a two-step algorithm for differentiation between normal and elevated LV filling pressure, defining values ≥ 15 mmHg as elevated. The parameters in the first step included the ratio between mitral early flow velocity and septal mitral annular velocity (septal E/e’), mitral E velocity, deceleration time of E, and peak tricuspid regurgitation velocity. Patients who could not be classified in the first step were tested in a second step by applying supplementary parameters, which included left atrial reservoir strain, pulmonary venous systolic/diastolic velocity ratio, and body mass index. This two-step algorithm classified patients as having either normal or elevated LV filling pressure with 75% accuracy and with 85% feasibility. Accuracy in EF ≥ 50% and EF < 50% was similar (75% and 76%). Conclusions: In patients with atrial fibrillation, no single echocardiographic parameter was sufficiently reliable to be used clinically to identify elevated LV filling pressure. An algorithm that combined several echocardiographic parameters and body mass index, however, was able to classify patients as having normal or elevated LV filling pressure with moderate accuracy and high feasibility.-
dc.description.statementOfResponsibilityopen-
dc.formatapplication/pdf-
dc.relation.isPartOfEcho Research and Practice-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.titleEvaluation of left ventricular filling pressure by echocardiography in patients with atrial fibrillation-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Internal Medicine (내과학교실)-
dc.contributor.googleauthorFaraz H Khan-
dc.contributor.googleauthorDebbie Zhao-
dc.contributor.googleauthorJong-Won Ha-
dc.contributor.googleauthorSherif F Nagueh-
dc.contributor.googleauthorJens-Uwe Voigt-
dc.contributor.googleauthorAllan L Klein-
dc.contributor.googleauthorEinar Gude-
dc.contributor.googleauthorKaspar Broch-
dc.contributor.googleauthorNicholas Chan-
dc.contributor.googleauthorGina M Quill-
dc.contributor.googleauthorRobert N Doughty-
dc.contributor.googleauthorAlistair Young-
dc.contributor.googleauthorJi-Won Seo-
dc.contributor.googleauthorEusebio García-Izquierdo-
dc.contributor.googleauthorVanessa Moñivas-Palomero-
dc.contributor.googleauthorSusana Mingo-Santos-
dc.contributor.googleauthorTom Kai Ming Wang-
dc.contributor.googleauthorStephanie Bezy-
dc.contributor.googleauthorNobuyuki Ohte-
dc.contributor.googleauthorHelge Skulstad-
dc.contributor.googleauthorCarmen C Beladan-
dc.contributor.googleauthorBogdan A Popescu-
dc.contributor.googleauthorShohei Kikuchi-
dc.contributor.googleauthorVasileios Panis-
dc.contributor.googleauthorErwan Donal-
dc.contributor.googleauthorEspen W Remme-
dc.contributor.googleauthorMartyn P Nash-
dc.contributor.googleauthorOtto A Smiseth-
dc.identifier.doi10.1186/s44156-024-00048-x-
dc.contributor.localIdA04257-
dc.identifier.pmid38825684-
dc.subject.keywordAtrial fibrillation-
dc.subject.keywordDiastolic function-
dc.subject.keywordEchocardiography-
dc.subject.keywordFilling pressure-
dc.subject.keywordLeft atrium-
dc.subject.keywordLeft ventricle-
dc.contributor.alternativeNameHa, Jong Won-
dc.contributor.affiliatedAuthor하종원-
dc.citation.volume11-
dc.citation.number1-
dc.citation.startPage14-
dc.identifier.bibliographicCitationEcho Research and Practice, Vol.11(1) : 14, 2024-06-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Internal Medicine (내과학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.