Cited 1 times in

Noise reduction in low-dose positron emission tomography with adaptive parameter estimation in sinogram domain

DC Field Value Language
dc.contributor.author이수환-
dc.date.accessioned2024-12-06T02:12:42Z-
dc.date.available2024-12-06T02:12:42Z-
dc.date.issued2024-10-
dc.identifier.issn1738-5733-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/200719-
dc.description.abstractNoise reduction in low-dose positron emission tomography (PET) is a well-researched topic aimed at reducing patient radiation doses and improving diagnosis. Software-based noise reduction mainly improves the contrast between regions by reducing the variation of the acquired image. However, it should be performed under appropriate parameters to reduce discrimination. We propose a method that derives optimal noise-reduction parameters using the multi-scale structural similarity index measure and visual information fidelity, which are metrics for image quality assessment. Simulation and experimental studies demonstrated the viability of the proposed algorithm. The contrast-to-noise ratio value of the denoised reconstruction slice, which was used as the optimal parameter, increased approximately three times compared to that of the low-dose slice while preserving the resolution. The results indicate that the proposed method successfully predicted the parameters according to the noise-reduction algorithm and PET system conditions in the sinogram domain. The proposed algorithm should help prevent misdiagnosis and provide standardized medical images for clinical application by performing appropriate noise reduction.-
dc.description.statementOfResponsibilityrestriction-
dc.languageEnglish-
dc.publisherKorea Nuclear Society-
dc.relation.isPartOfNUCLEAR ENGINEERING AND TECHNOLOGY-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.titleNoise reduction in low-dose positron emission tomography with adaptive parameter estimation in sinogram domain-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Internal Medicine (내과학교실)-
dc.contributor.googleauthorKyu Bom Kim-
dc.contributor.googleauthorYeonkyeong Kim-
dc.contributor.googleauthorKyuseok Kim-
dc.contributor.googleauthorSu Hwan Lee-
dc.identifier.doi10.1016/j.net.2024.05.015-
dc.contributor.localIdA02904-
dc.relation.journalcodeJ03972-
dc.identifier.urlhttps://www.sciencedirect.com/science/article/pii/S1738573324002298-
dc.subject.keywordNoise reduction-
dc.subject.keywordLow-dose-
dc.subject.keywordParameter estimation-
dc.subject.keywordImage quality assessment-
dc.subject.keywordPositron emission tomography-
dc.contributor.alternativeNameLee, Su Hwan-
dc.contributor.affiliatedAuthor이수환-
dc.citation.volume56-
dc.citation.number10-
dc.citation.startPage4127-
dc.citation.endPage4133-
dc.identifier.bibliographicCitationNUCLEAR ENGINEERING AND TECHNOLOGY, Vol.56(10) : 4127-4133, 2024-10-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Internal Medicine (내과학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.