Cited 1 times in
Noise reduction in low-dose positron emission tomography with adaptive parameter estimation in sinogram domain
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 이수환 | - |
dc.date.accessioned | 2024-12-06T02:12:42Z | - |
dc.date.available | 2024-12-06T02:12:42Z | - |
dc.date.issued | 2024-10 | - |
dc.identifier.issn | 1738-5733 | - |
dc.identifier.uri | https://ir.ymlib.yonsei.ac.kr/handle/22282913/200719 | - |
dc.description.abstract | Noise reduction in low-dose positron emission tomography (PET) is a well-researched topic aimed at reducing patient radiation doses and improving diagnosis. Software-based noise reduction mainly improves the contrast between regions by reducing the variation of the acquired image. However, it should be performed under appropriate parameters to reduce discrimination. We propose a method that derives optimal noise-reduction parameters using the multi-scale structural similarity index measure and visual information fidelity, which are metrics for image quality assessment. Simulation and experimental studies demonstrated the viability of the proposed algorithm. The contrast-to-noise ratio value of the denoised reconstruction slice, which was used as the optimal parameter, increased approximately three times compared to that of the low-dose slice while preserving the resolution. The results indicate that the proposed method successfully predicted the parameters according to the noise-reduction algorithm and PET system conditions in the sinogram domain. The proposed algorithm should help prevent misdiagnosis and provide standardized medical images for clinical application by performing appropriate noise reduction. | - |
dc.description.statementOfResponsibility | restriction | - |
dc.language | English | - |
dc.publisher | Korea Nuclear Society | - |
dc.relation.isPartOf | NUCLEAR ENGINEERING AND TECHNOLOGY | - |
dc.rights | CC BY-NC-ND 2.0 KR | - |
dc.title | Noise reduction in low-dose positron emission tomography with adaptive parameter estimation in sinogram domain | - |
dc.type | Article | - |
dc.contributor.college | College of Medicine (의과대학) | - |
dc.contributor.department | Dept. of Internal Medicine (내과학교실) | - |
dc.contributor.googleauthor | Kyu Bom Kim | - |
dc.contributor.googleauthor | Yeonkyeong Kim | - |
dc.contributor.googleauthor | Kyuseok Kim | - |
dc.contributor.googleauthor | Su Hwan Lee | - |
dc.identifier.doi | 10.1016/j.net.2024.05.015 | - |
dc.contributor.localId | A02904 | - |
dc.relation.journalcode | J03972 | - |
dc.identifier.url | https://www.sciencedirect.com/science/article/pii/S1738573324002298 | - |
dc.subject.keyword | Noise reduction | - |
dc.subject.keyword | Low-dose | - |
dc.subject.keyword | Parameter estimation | - |
dc.subject.keyword | Image quality assessment | - |
dc.subject.keyword | Positron emission tomography | - |
dc.contributor.alternativeName | Lee, Su Hwan | - |
dc.contributor.affiliatedAuthor | 이수환 | - |
dc.citation.volume | 56 | - |
dc.citation.number | 10 | - |
dc.citation.startPage | 4127 | - |
dc.citation.endPage | 4133 | - |
dc.identifier.bibliographicCitation | NUCLEAR ENGINEERING AND TECHNOLOGY, Vol.56(10) : 4127-4133, 2024-10 | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.