Cited 0 times in

텍스트 네트워크 분석을 통한 환자중앙감시시스템의 사용적합성 평가를 위한 위해요인 분석

DC Field Value Language
dc.contributor.author장원석-
dc.date.accessioned2024-10-04T02:29:21Z-
dc.date.available2024-10-04T02:29:21Z-
dc.date.issued2024-08-
dc.identifier.issn1229-0807-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/200513-
dc.description.abstractIn this study, text network analysis was performed using PMS(Post-Marketing Surveillance) data collected from the FDA's MAUDE(Manufacturer and User Facility Device Experience) database to evaluate the usability of the central monitoring system. Based on the data reported from January 1, 2021 to June 30, 2023, keywords related to the central monitoring system were extracted and visualized with a text network. By analyzing the eigenvector centrality of text network, we identified hazards and types of hazardous situations related to usability of the central monitoring system. Eigenvector centrality was chosen because it is relatively more accurate than other centralities. In addition, we derived an appropriate use scenario to evaluate the usability of the central monitoring system. The research results provide more realistic and valuable insights through data derived based on actual adverse event cases, and are expected to contribute to improving safety and reliability by identifying user requirements for improved usability and reducing use errors in the future.-
dc.description.statementOfResponsibilityopen-
dc.formatapplication/pdf-
dc.languageKorean-
dc.publisherThe Korea Society of Medical and Biological Engineering-
dc.relation.isPartOfJournal of Biomedical Engineering Research(의공학회지)-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.title텍스트 네트워크 분석을 통한 환자중앙감시시스템의 사용적합성 평가를 위한 위해요인 분석-
dc.title.alternativeHazard Analysis for Usability Evaluation of Central Monitoring System through Text Network Analysis-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Medical Engineering (의학공학교실)-
dc.contributor.googleauthor정지용-
dc.contributor.googleauthor장원석-
dc.identifier.doi10.9718/JBER.2024.45.4.187-
dc.contributor.localIdA04793-
dc.relation.journalcodeJ01263-
dc.subject.keywordCentral monitoring system-
dc.subject.keywordUsability-
dc.subject.keywordHazard-related use scenario-
dc.subject.keywordText network-
dc.subject.keywordCentrality-
dc.contributor.alternativeNameChang, Won Seok-
dc.contributor.affiliatedAuthor장원석-
dc.citation.volume45-
dc.citation.number4-
dc.citation.startPage187-
dc.citation.endPage194-
dc.identifier.bibliographicCitationJournal of Biomedical Engineering Research(의공학회지), Vol.45(4) : 187-194, 2024-08-
Appears in Collections:
1. College of Medicine (의과대학) > BioMedical Science Institute (의생명과학부) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.