Cited 0 times in
Development of Magnetic Resonance-Compatible Head Immobilization Device and Initial Experience of Magnetic Resonance-Guided Radiation Therapy for Central Nervous System Tumors
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 김준원 | - |
dc.date.accessioned | 2024-10-04T02:21:32Z | - |
dc.date.available | 2024-10-04T02:21:32Z | - |
dc.date.issued | 2024-09 | - |
dc.identifier.issn | 1879-8500 | - |
dc.identifier.uri | https://ir.ymlib.yonsei.ac.kr/handle/22282913/200470 | - |
dc.description.abstract | Purpose: We aimed to develop and investigate positional reproducibility using a fixation device (Unity Brain tumor Immobilization Device [UBID]) in patients with brain tumor undergoing magnetic resonance (MR)-guided radiation therapy (RT) with a 1.5 Tesla (T) MR-linear accelerator (MR-LINAC) to evaluate its feasibility in clinical practice and report representative cases of patients with central nervous system (CNS) tumor. Materials and methods: Quantitative analysis was performed by comparing images obtained by placing only the MR phantom on the couch with those obtained by placing UBID next to the MR phantom. Twenty patients who underwent RT for CNS tumors using 1.5T MR-LINAC between June and October 2022 were retrospectively analyzed. Among them, 5 did not use UBID, whereas 15 used UBID. The positional reproducibility of UBID was evaluated using the median interfractional and intrafractional errors in the first 10 fractions. Results: Each MR quality factor of the MR phantom with UBID satisfied the criteria presented by Elekta. Median values of median shifts in the mediolateral, anteroposterior, and craniocaudal axes for interfractional errors were 2.98, 2.35, and 1.40 mm, respectively. For intrafractional errors, the median values were 0.05, 0.03, and 0.06 mm, respectively. The median values of the median rotations in pitch, roll, and yaw for both interfractional and intrafractional rotations were 0.00°. One patient diagnosed with an optic nerve sheath meningioma received RT with motion monitoring during irradiation. In 2 patients, changes in the tumor cavity and residual lesions were observed in the MRI obtained using 1.5T MR-LINAC on the day of the first treatment and immediately before the 21st fraction, respectively; therefore, offline/online adaptation was performed. Conclusions: The reproducible and immobile UBID is clinically feasible in patients with CNS tumors receiving RT with 1.5T MR-LINAC. Based on our initial experience, we developed a workflow for 1.5T MR-LINAC treatment of CNS tumors. | - |
dc.description.statementOfResponsibility | restriction | - |
dc.language | English | - |
dc.publisher | Elsevier | - |
dc.relation.isPartOf | PRACTICAL RADIATION ONCOLOGY | - |
dc.rights | CC BY-NC-ND 2.0 KR | - |
dc.subject.MESH | Adult | - |
dc.subject.MESH | Aged | - |
dc.subject.MESH | Central Nervous System Neoplasms / diagnostic imaging | - |
dc.subject.MESH | Central Nervous System Neoplasms / radiotherapy | - |
dc.subject.MESH | Female | - |
dc.subject.MESH | Humans | - |
dc.subject.MESH | Immobilization* / instrumentation | - |
dc.subject.MESH | Immobilization* / methods | - |
dc.subject.MESH | Magnetic Resonance Imaging* / methods | - |
dc.subject.MESH | Male | - |
dc.subject.MESH | Middle Aged | - |
dc.subject.MESH | Phantoms, Imaging | - |
dc.subject.MESH | Radiotherapy Planning, Computer-Assisted / methods | - |
dc.subject.MESH | Radiotherapy, Image-Guided* / methods | - |
dc.subject.MESH | Retrospective Studies | - |
dc.title | Development of Magnetic Resonance-Compatible Head Immobilization Device and Initial Experience of Magnetic Resonance-Guided Radiation Therapy for Central Nervous System Tumors | - |
dc.type | Article | - |
dc.contributor.college | College of Medicine (의과대학) | - |
dc.contributor.department | Dept. of Radiation Oncology (방사선종양학교실) | - |
dc.contributor.googleauthor | Joongyo Lee | - |
dc.contributor.googleauthor | Na Young Shin | - |
dc.contributor.googleauthor | Seo Jin Lee | - |
dc.contributor.googleauthor | Yoon Jin Cho | - |
dc.contributor.googleauthor | In Ho Jung | - |
dc.contributor.googleauthor | Ji Won Sung | - |
dc.contributor.googleauthor | Sei Joon Kim | - |
dc.contributor.googleauthor | Jun Won Kim | - |
dc.identifier.doi | 38697347 | - |
dc.contributor.localId | A00958 | - |
dc.relation.journalcode | J04363 | - |
dc.identifier.eissn | 1879-8519 | - |
dc.identifier.pmid | 10.1016/j.prro.2024.04.012 | - |
dc.identifier.url | https://www.sciencedirect.com/science/article/pii/S1879850024000936 | - |
dc.contributor.alternativeName | Kim, Jun Won | - |
dc.contributor.affiliatedAuthor | 김준원 | - |
dc.citation.volume | 14 | - |
dc.citation.number | 5 | - |
dc.citation.startPage | e324 | - |
dc.citation.endPage | e333 | - |
dc.identifier.bibliographicCitation | PRACTICAL RADIATION ONCOLOGY, Vol.14(5) : e324-e333, 2024-09 | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.