Cited 8 times in
Fluid-structure interaction simulation of visceral perfusion and impact of different cannulation methods on aortic dissection
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 김태훈 | - |
dc.contributor.author | 송석원 | - |
dc.date.accessioned | 2024-03-22T05:58:15Z | - |
dc.date.available | 2024-03-22T05:58:15Z | - |
dc.date.issued | 2023-01 | - |
dc.identifier.uri | https://ir.ymlib.yonsei.ac.kr/handle/22282913/198313 | - |
dc.description.abstract | Hemodynamics in aortic dissection (AD) is closely associated with the risk of aortic aneurysm, rupture, and malperfusion. Altered blood flow in patients with AD can lead to severe complications such as visceral malperfusion. In this study, we aimed to investigate the effect of cannulation flow on hemodynamics in AD using a fluid–structure interaction simulation. We developed a specific-idealized AD model that included an intimal tear in the descending thoracic aorta, a re-entry tear in the left iliac artery, and nine branches. Two different cannulation methods were tested: (1) axillary cannulation (AC) only through the brachiocephalic trunk and (2) combined axillary and femoral cannulation (AFC) through the brachiocephalic trunk and the right common iliac artery. AC was found to result in the development of a pressure difference between the true lumen and false lumen, owing to the difference in the flow rate through each lumen. This pressure difference collapsed the true lumen, disturbing blood flow to the celiac and superior mesenteric arteries. However, in AFC, the pressure levels between the two lumens were similar, and no collapse occurred. Moreover, the visceral flow was higher than that in AC. Lastly, the stiffness of the intimal flap affected the true lumen's collapse. © 2023, The Author(s). | - |
dc.description.statementOfResponsibility | open | - |
dc.format | application/pdf | - |
dc.language | English | - |
dc.publisher | Nature Publishing Group | - |
dc.relation.isPartOf | SCIENTIFIC REPORTS | - |
dc.rights | CC BY-NC-ND 2.0 KR | - |
dc.subject.MESH | Aorta, Abdominal | - |
dc.subject.MESH | Aortic Aneurysm* / surgery | - |
dc.subject.MESH | Aortic Aneurysm, Thoracic* / surgery | - |
dc.subject.MESH | Aortic Dissection* | - |
dc.subject.MESH | Catheterization | - |
dc.subject.MESH | Humans | - |
dc.subject.MESH | Perfusion | - |
dc.subject.MESH | Treatment Outcome | - |
dc.title | Fluid-structure interaction simulation of visceral perfusion and impact of different cannulation methods on aortic dissection | - |
dc.type | Article | - |
dc.contributor.college | College of Medicine (의과대학) | - |
dc.contributor.department | Dept. of Thoracic and Cardiovascular Surgery (흉부외과학교실) | - |
dc.contributor.googleauthor | Gyu-Han Lee | - |
dc.contributor.googleauthor | Woon Heo | - |
dc.contributor.googleauthor | Youngjin Lee | - |
dc.contributor.googleauthor | Tae-Hoon Kim | - |
dc.contributor.googleauthor | Hyungkyu Huh | - |
dc.contributor.googleauthor | Suk-Won Song | - |
dc.contributor.googleauthor | Hojin Ha | - |
dc.identifier.doi | 10.1038/s41598-023-27855-2 | - |
dc.contributor.localId | A04737 | - |
dc.contributor.localId | A02028 | - |
dc.relation.journalcode | J02646 | - |
dc.identifier.eissn | 2045-2322 | - |
dc.identifier.pmid | 36670162 | - |
dc.contributor.alternativeName | Kim, Tae Hoon | - |
dc.contributor.affiliatedAuthor | 김태훈 | - |
dc.contributor.affiliatedAuthor | 송석원 | - |
dc.citation.volume | 13 | - |
dc.citation.number | 1 | - |
dc.citation.startPage | 1116 | - |
dc.identifier.bibliographicCitation | SCIENTIFIC REPORTS, Vol.13(1) : 1116, 2023-01 | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.