0 123

Cited 1 times in

Implant-retained overdenture delivery in 2 visits with a digital workflow

DC Field Value Language
dc.contributor.author김선재-
dc.contributor.author장재승-
dc.date.accessioned2024-02-15T06:39:50Z-
dc.date.available2024-02-15T06:39:50Z-
dc.date.issued2023-11-
dc.identifier.issn0022-3913-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/197983-
dc.description.abstractThe conventional method of fabricating implant-retained overdentures involves multiple steps and patient visits. However, the duplication of existing complete dentures could decrease the number of visits and increase patient satisfaction. An existing maxillary implant-retained overdenture was replaced for a 78-year-old man; the existing implant-retained overdenture and his face were scanned at the first visit. The scanned intaglio image was inverted to obtain a virtual maxillary cast and used to fabricate the metal framework of the replacement implant-retained overdenture. Prefabricated artificial teeth were arranged on a 3-dimensional trial denture created from the scan data of the existing implant-retained overdenture. The replacement implantretained overdenture was fabricated on the metal framework by using the injection molding technique. By using these digital techniques, a stable and esthetic implant-retained overdenture was delivered in 2 visits. (J Prosthet Dent 2023;130:663-7)-
dc.description.statementOfResponsibilityrestriction-
dc.languageEnglish-
dc.publisherMosby-Year Book-
dc.relation.isPartOfJOURNAL OF PROSTHETIC DENTISTRY-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.subject.MESHAged-
dc.subject.MESHDental Implants*-
dc.subject.MESHDental Prosthesis, Implant-Supported-
dc.subject.MESHDenture Retention-
dc.subject.MESHDenture, Complete-
dc.subject.MESHDenture, Complete, Lower-
dc.subject.MESHDenture, Overlay-
dc.subject.MESHEsthetics, Dental-
dc.subject.MESHHumans-
dc.subject.MESHMale-
dc.subject.MESHMandible-
dc.subject.MESHPatient Satisfaction-
dc.subject.MESHWorkflow-
dc.titleImplant-retained overdenture delivery in 2 visits with a digital workflow-
dc.typeArticle-
dc.contributor.collegeCollege of Dentistry (치과대학)-
dc.contributor.departmentDept. of Prosthodontics (보철과학교실)-
dc.contributor.googleauthorSeung-Hoe Jeong-
dc.contributor.googleauthorSunjai Kim-
dc.contributor.googleauthorYou Won Seong-
dc.contributor.googleauthorJae-Seung Chang-
dc.identifier.doi10.1016/j.prosdent.2021.12.023-
dc.contributor.localIdA00558-
dc.contributor.localIdA03462-
dc.relation.journalcodeJ01718-
dc.identifier.eissn1097-6841-
dc.identifier.pmid35256185-
dc.identifier.urlhttps://www.sciencedirect.com/science/article/pii/S0022391322000130-
dc.contributor.alternativeNameKim, Sun Jai-
dc.contributor.affiliatedAuthor김선재-
dc.contributor.affiliatedAuthor장재승-
dc.citation.volume130-
dc.citation.number5-
dc.citation.startPage663-
dc.citation.endPage667-
dc.identifier.bibliographicCitationJOURNAL OF PROSTHETIC DENTISTRY, Vol.130(5) : 663-667, 2023-11-
Appears in Collections:
2. College of Dentistry (치과대학) > Dept. of Prosthodontics (보철과학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.