211 330

Cited 0 times in

Cited 1 times in

Simulation Method for the Physical Deformation of a ThreeDimensional Soft Body in Augmented RealityBased External Ventricular Drainage

DC Field Value Language
dc.contributor.authorKoo, Kyoyeong-
dc.contributor.authorPark, Taeyong-
dc.contributor.authorJeong, Heeryeol-
dc.contributor.authorKhang, Seungwoo-
dc.contributor.authorKoh, Chin Su-
dc.contributor.authorPark, Minkyung-
dc.contributor.authorKim, Myung Ji-
dc.contributor.authorJung, Hyun Ho-
dc.contributor.authorShin, Juneseuk-
dc.contributor.authorKim, Kyung Won-
dc.contributor.authorLee, Jeongjin-
dc.date.accessioned2024-01-16T01:53:26Z-
dc.date.available2024-01-16T01:53:26Z-
dc.date.created2024-01-30-
dc.date.issued2023-07-
dc.identifier.issn2093-3681-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/197774-
dc.description.abstractObjectives: Intraoperative navigation reduces the risk of major complications and increases the likelihood of optimal surgi-cal outcomes. This paper presents an augmented reality (AR)-based simulation technique for ventriculostomy that visualizes brain deformations caused by the movements of a surgical instrument in a three-dimensional brain model. This is achieved by utilizing a position-based dynamics (PBD) physical deformation method on a preoperative brain image. Methods: An in-frared camera-based AR surgical environment aligns the real-world space with a virtual space and tracks the surgical instru-ments. For a realistic representation and reduced simulation computation load, a hybrid geometric model is employed, which combines a high-resolution mesh model and a multiresolution tetrahedron model. Collision handling is executed when a col-lision between the brain and surgical instrument is detected. Constraints are used to preserve the properties of the soft body and ensure stable deformation. Results: The experiment was conducted once in a phantom environment and once in an ac-tual surgical environment. The tasks of inserting the surgical instrument into the ventricle using only the navigation informa-tion presented through the smart glasses and verifying the drainage of cerebrospinal fluid were evaluated. These tasks were successfully completed, as indicated by the drainage, and the deformation simulation speed averaged 18.78 fps. Conclusions: This experiment confirmed that the AR-based method for external ventricular drain surgery was beneficial to clinicians.-
dc.description.statementOfResponsibilityopen-
dc.formatapplication/pdf-
dc.languageKorean-
dc.publisherKorean Society of Medical Informatics-
dc.relation.isPartOfHEALTHCARE INFORMATICS RESEARCH-
dc.relation.isPartOfHEALTHCARE INFORMATICS RESEARCH-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.titleSimulation Method for the Physical Deformation of a ThreeDimensional Soft Body in Augmented RealityBased External Ventricular Drainage-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Neurosurgery (신경외과학교실)-
dc.contributor.googleauthorKoo, Kyoyeong-
dc.contributor.googleauthorPark, Taeyong-
dc.contributor.googleauthorJeong, Heeryeol-
dc.contributor.googleauthorKhang, Seungwoo-
dc.contributor.googleauthorKoh, Chin Su-
dc.contributor.googleauthorPark, Minkyung-
dc.contributor.googleauthorKim, Myung Ji-
dc.contributor.googleauthorJung, Hyun Ho-
dc.contributor.googleauthorShin, Juneseuk-
dc.contributor.googleauthorKim, Kyung Won-
dc.contributor.googleauthorLee, Jeongjin-
dc.identifier.doi10.4258/hir.2023.29.3.218-
dc.relation.journalcodeJ00974-
dc.identifier.eissn2093-369X-
dc.identifier.pmid37591677-
dc.subject.keywordAugmented Reality-
dc.subject.keywordVentriculostomy-
dc.subject.keywordSurgical Navigation Systems-
dc.subject.keywordComputer Simulation-
dc.subject.keywordBiomechanical Phenomena-
dc.contributor.alternativeNameJung, Hyun Ho-
dc.contributor.affiliatedAuthorKoh, Chin Su-
dc.contributor.affiliatedAuthorJung, Hyun Ho-
dc.identifier.scopusid2-s2.0-85167609219-
dc.identifier.wosid001096213900005-
dc.citation.volume29-
dc.citation.number3-
dc.citation.startPage218-
dc.citation.endPage227-
dc.identifier.bibliographicCitationHEALTHCARE INFORMATICS RESEARCH, Vol.29(3) : 218-227, 2023-07-
dc.identifier.rimsid82077-
dc.type.rimsART-
dc.description.journalClass1-
dc.description.journalClass1-
dc.subject.keywordAuthorAugmented Reality-
dc.subject.keywordAuthorVentriculostomy-
dc.subject.keywordAuthorSurgical Navigation Systems-
dc.subject.keywordAuthorComputer Simulation-
dc.subject.keywordAuthorBiomechanical Phenomena-
dc.subject.keywordPlusBRAIN SHIFT-
dc.subject.keywordPlusNEURONAVIGATION-
dc.subject.keywordPlusMODELS-
dc.type.docTypeArticle-
dc.identifier.kciidART002985239-
dc.description.isOpenAccessY-
dc.description.journalRegisteredClassscopus-
dc.description.journalRegisteredClasskci-
dc.relation.journalWebOfScienceCategoryMedical Informatics-
dc.relation.journalResearchAreaMedical Informatics-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Neurosurgery (신경외과학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.