| dc.description.abstract | Background: This study aims to develop an evaluator that can quickly and accurately evaluate the shielding of low-energy industrial radiation generators.Methods: We used PyQt to develop a graphical user interface (GUI)-based program and employed the calculation methodology reported in the National Council on Radiation Protection and Measurements (NCRP)-49 for shielding calculations. We gathered the necessary factors for shielding evaluation using two libraries designed for Python, pandas and NumPy, and processed them into a database. We verified the effectiveness of the proposed program by comparing the results with those from safety reports of six domestic facilities. Results: After verifying the effectiveness of the program using the NCRP-49 example, we obtained an average error rate of 1.73%. When comparing the facility safety report and results obtained using the program, we found that the error rate was between 1.09% and 6.51%. However, facilities that did not use a defined shielding methodology were underestimated by 31.82% compared with the program (the final barrier thickness satisfied the shielding standard).Conclusion: The developed program provides a fast and accurate shielding evaluation that can assist personnel that work in radiation generator facilities and government officials in reviewing safety.(c) 2023 Korean Nuclear Society, Published by Elsevier Korea LLC. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). | - |
| dc.description.statementOfResponsibility | restriction | - |
| dc.language | English | - |
| dc.publisher | Korea Nuclear Society | - |
| dc.relation.isPartOf | NUCLEAR ENGINEERING AND TECHNOLOGY | - |
| dc.relation.isPartOf | NUCLEAR ENGINEERING AND TECHNOLOGY | - |
| dc.rights | CC BY-NC-ND 2.0 KR | - |
| dc.title | Preliminary study for the development of radiation safety evaluation methodology for industrial kV-rated radiation generator facilities | - |
| dc.type | Article | - |
| dc.contributor.college | College of Medicine (의과대학) | - |
| dc.contributor.department | Dept. of Radiation Oncology (방사선종양학교실) | - |
| dc.contributor.googleauthor | Park, Hye Sung | - |
| dc.contributor.googleauthor | Kwon, Na Hye | - |
| dc.contributor.googleauthor | Kim, Sang Rok | - |
| dc.contributor.googleauthor | Yoo, Hwidong | - |
| dc.contributor.googleauthor | Kim, Jin Sung | - |
| dc.contributor.googleauthor | Choi, Sang Hyoun | - |
| dc.contributor.googleauthor | Kim, Dong Wook | - |
| dc.identifier.doi | 10.1016/j.net.2023.06.051 | - |
| dc.relation.journalcode | J03972 | - |
| dc.subject.keyword | Radiation shielding | - |
| dc.subject.keyword | X-ray | - |
| dc.subject.keyword | Transmitted dose | - |
| dc.subject.keyword | Evaluator | - |
| dc.subject.keyword | Tube voltage | - |
| dc.subject.keyword | Filter | - |
| dc.contributor.alternativeName | Kim, Dong Wook | - |
| dc.contributor.affiliatedAuthor | Kim, Jin Sung | - |
| dc.contributor.affiliatedAuthor | Kim, Dong Wook | - |
| dc.identifier.scopusid | 2-s2.0-85165149289 | - |
| dc.identifier.wosid | 001091765000001 | - |
| dc.citation.volume | 55 | - |
| dc.citation.number | 10 | - |
| dc.citation.startPage | 3854 | - |
| dc.citation.endPage | 3859 | - |
| dc.identifier.bibliographicCitation | NUCLEAR ENGINEERING AND TECHNOLOGY, Vol.55(10) : 3854-3859, 2023-10 | - |
| dc.identifier.rimsid | 81957 | - |
| dc.type.rims | ART | - |
| dc.description.journalClass | 1 | - |
| dc.description.journalClass | 1 | - |
| dc.subject.keywordAuthor | Radiation shielding | - |
| dc.subject.keywordAuthor | X-ray | - |
| dc.subject.keywordAuthor | Transmitted dose | - |
| dc.subject.keywordAuthor | Evaluator | - |
| dc.subject.keywordAuthor | Tube voltage | - |
| dc.subject.keywordAuthor | Filter | - |
| dc.subject.keywordPlus | ATTENUATION | - |
| dc.subject.keywordPlus | CONCRETE | - |
| dc.subject.keywordPlus | LEAD | - |
| dc.type.docType | Article | - |
| dc.identifier.kciid | ART003006830 | - |
| dc.description.isOpenAccess | Y | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.relation.journalWebOfScienceCategory | Nuclear Science & Technology | - |
| dc.relation.journalResearchArea | Nuclear Science & Technology | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.