61 130

Cited 2 times in

Evaluating the Efficiency of the Cobas 6800 System for BK Virus Detection in Plasma and Urine Samples

DC Field Value Language
dc.contributor.author김신영-
dc.contributor.author박윤희-
dc.contributor.author송준협-
dc.date.accessioned2023-10-19T06:06:17Z-
dc.date.available2023-10-19T06:06:17Z-
dc.date.issued2023-09-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/196356-
dc.description.abstractWe evaluated the overall performance of the Cobas 6800 BKV test in detecting BK virus (BKV). We examined the imprecision of the Cobas 6800 BKV test and compared the qualitative and quantitative results obtained from the Cobas 6800 BKV test and the Real-Q BKV quantification assay. We assessed 88 plasma and 26 urine samples collected between September and November 2022 from patients with BKV infection using the Real-Q BKV quantitative assay. The lognormal coefficient of variation indicated that the inter-assay precision of the Cobas 6800 BKV test ranged from 13.86 to 33.83%. A strong correlation was observed between the quantitative results obtained using the Cobas 6800 BKV test and the Real-Q BKV quantification assay for plasma samples. The Spearman's rank correlation coefficients (ρ) for plasma, polymerase chain reaction (PCR) media-stabilized urine, and raw urine samples were 0.939, 0.874, and 0.888, respectively. Our analyses suggest that the Cobas 6800 BKV test is suitable for clinical applications owing to the strong correlation between the results obtained using this test and the Real-Q BKV quantification assay in plasma and urine samples. Furthermore, utilizing fresh raw urine samples can be a viable approach for the Cobas 6800 BKV test as it is less labor- and time-intensive.-
dc.description.statementOfResponsibilityopen-
dc.formatapplication/pdf-
dc.languageEnglish-
dc.publisherMDPI AG-
dc.relation.isPartOfDIAGNOSTICS-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.titleEvaluating the Efficiency of the Cobas 6800 System for BK Virus Detection in Plasma and Urine Samples-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Laboratory Medicine (진단검사의학교실)-
dc.contributor.googleauthorJunhyup Song-
dc.contributor.googleauthorSinyoung Kim-
dc.contributor.googleauthorEunmin Kwak-
dc.contributor.googleauthorYounhee Park-
dc.identifier.doi10.3390/diagnostics13172860-
dc.contributor.localIdA00675-
dc.contributor.localIdA01606-
dc.relation.journalcodeJ03798-
dc.identifier.eissn2075-4418-
dc.identifier.pmid37685397-
dc.subject.keywordBK virus-
dc.subject.keywordCobas 6800-
dc.subject.keywordanalytical performance-
dc.subject.keywordautomated assay system-
dc.subject.keywordmethod comparison-
dc.contributor.alternativeNameKim, Sin Young-
dc.contributor.affiliatedAuthor김신영-
dc.contributor.affiliatedAuthor박윤희-
dc.citation.volume13-
dc.citation.number17-
dc.citation.startPage2860-
dc.identifier.bibliographicCitationDIAGNOSTICS, Vol.13(17) : 2860, 2023-09-