0 348

Cited 0 times in

Cited 11 times in

A laboratory association between hemoglobin and VerifyNow P2Y12 reaction unit: A systematic review and meta-analysis

DC Field Value Language
dc.contributor.authorKim, Yun Gi-
dc.contributor.authorSuh, Jung-Won-
dc.contributor.authorSibbing, Dirk-
dc.contributor.authorKastrati, Adnan-
dc.contributor.authorKo, Young Guk-
dc.contributor.authorJang, Yang Soo-
dc.contributor.authorCho, Young-Seok-
dc.contributor.authorYoun, Tae-Jin-
dc.contributor.authorChae, In-Ho-
dc.contributor.authorChoi, Dong-Ju-
dc.contributor.authorKim, Hyo-Soo-
dc.date.accessioned2023-08-22T07:17:59Z-
dc.date.available2023-08-22T07:17:59Z-
dc.date.created2023-08-23-
dc.date.issued2017-06-
dc.identifier.issn0002-8703-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/196107-
dc.description.abstractBackground VerifyNow P2Y12 assay is used widely to evaluate residual platelet reactivity in patients taking P2Y12 receptor antagonists. However, a laboratory association between VerifyNow P2Y12 reaction unit (PRU) and hemoglobin, which might lead to wrong interpretation of the data, is reported. We performed these systematic review and meta-analysis to clearly define the relationship between PRU and hemoglobin and to elucidate whether the relationship, if any, is a true biological association or is just a laboratory error. Methods Through a comprehensive electronic and manual search, 10 studies were selected for the cohort level meta analysis. Among 10 studies, we were able to retrieve the raw data of 5 studies, and a patient-level meta-analysis was performed. Potential publication bias was searched by funnel plot analysis and was actively adjusted, if present, by trim and fill method. Results The pooled analysis revealed a significant inverse correlation between PRU and hemoglobin (r = 0.349; P <.001; 10 studies with 4,793 patients). VerifyNow P2Y12 base unit, which reflects off-drug platelet reactivity, was also inversely correlated with hemoglobin (r = 0.526; P<.001; 8 studies with 4,395 patients). % Inhibition (r = 0.081; P =.059; 6 studies with 3,832 patients) and Delta PRU (r = 0.037; P =.188; 5 studies with 3,521 patients) were not associated with hemoglobin. A significant inverse association between PRU and hemoglobin was also observed in the patient-level meta analysis (3,533 patients pooled from 5 studies; r = 0.335; P<.001). Light transmission aggregometry (r = 0.160; P=.072; 4 studies with 1,144 patients) and multiple electrode platelet aggregometry (r = 0.029; P = .394; 3 studies with 7,645 patients) showed no significant association with hemoglobin. Conclusions A significant inverse association was observed between PRU and hemoglobin which is likely to be a laboratory error. Clinicians should be aware that this association might lead to wrong interpretation of the data.-
dc.description.statementOfResponsibilityrestriction-
dc.languageEnglish-
dc.publisherMosby-
dc.relation.isPartOfAmerican Heart Journal-
dc.relation.isPartOfAMERICAN HEART JOURNAL-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.titleA laboratory association between hemoglobin and VerifyNow P2Y12 reaction unit: A systematic review and meta-analysis-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Internal Medicine (내과학교실)-
dc.contributor.googleauthorKim, Yun Gi-
dc.contributor.googleauthorSuh, Jung-Won-
dc.contributor.googleauthorSibbing, Dirk-
dc.contributor.googleauthorKastrati, Adnan-
dc.contributor.googleauthorKo, Young Guk-
dc.contributor.googleauthorJang, Yang Soo-
dc.contributor.googleauthorCho, Young-Seok-
dc.contributor.googleauthorYoun, Tae-Jin-
dc.contributor.googleauthorChae, In-Ho-
dc.contributor.googleauthorChoi, Dong-Ju-
dc.contributor.googleauthorKim, Hyo-Soo-
dc.identifier.doi10.1016/j.ahj.2017.03.006-
dc.relation.journalcodeJ00069-
dc.identifier.eissn1097-6744-
dc.identifier.pmid28577681-
dc.contributor.alternativeNameJang, Yang Soo-
dc.contributor.affiliatedAuthorKo, Young Guk-
dc.contributor.affiliatedAuthorJang, Yang Soo-
dc.identifier.scopusid2-s2.0-85016066754-
dc.identifier.wosid000403197800007-
dc.citation.volume188-
dc.citation.startPage53-
dc.citation.endPage64-
dc.identifier.bibliographicCitationAmerican Heart Journal, Vol.188 : 53-64, 2017-06-
dc.identifier.rimsid80770-
dc.type.rimsART-
dc.description.journalClass1-
dc.description.journalClass1-
dc.subject.keywordPlusPERCUTANEOUS CORONARY INTERVENTION-
dc.subject.keywordPlusELECTRODE PLATELET AGGREGOMETRY-
dc.subject.keywordPlusELUTING STENT IMPLANTATION-
dc.subject.keywordPlusANTIPLATELET THERAPY-
dc.subject.keywordPlusARTERY-DISEASE-
dc.subject.keywordPlusCLOPIDOGREL RESPONSIVENESS-
dc.subject.keywordPlusMYOCARDIAL-INFARCTION-
dc.subject.keywordPlusPUBLICATION BIAS-
dc.subject.keywordPlusFUNCTION TESTS-
dc.subject.keywordPlusASSAY-
dc.type.docTypeReview-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalWebOfScienceCategoryCardiac & Cardiovascular Systems-
dc.relation.journalResearchAreaCardiovascular System & Cardiology-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Internal Medicine (내과학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.