82 176

Cited 2 times in

Evaluation of the machinability and machining accuracy of polymer-based CAD/CAM blocks using merlon fracture test model

DC Field Value Language
dc.contributor.author박영범-
dc.date.accessioned2023-08-09T06:57:09Z-
dc.date.available2023-08-09T06:57:09Z-
dc.date.issued2023-04-
dc.identifier.issn0287-4547-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/196009-
dc.description.abstractThe aims of this study were to estimate the machinability and machining accuracy of polymer-based CAM blocks using the merlon fracture test model specified in ISO 18675: 2022. Three hybrid disc blanks (MazicDuro, HC Disk, and Enamic) and three polymethyl methacrylate (PMMA) disc blanks (PMMA Disk, PMMA Block, and MazicTemp Hybrid) were tested in this study. The machinability was evaluated by assigning scores according to the fracture range of merlons with areas divided by ten vertical planes. The machining accuracy was evaluated by superimposing methods via CAD reference data and CAD specimen data. Within the limits of this study, a thickness of 0.3 mm is recommended for the clinical application of polymer-based CAD/CAM blocks in dental restorations that require superior machinability and accuracy. In addition, the machinability and machining accuracy tests of polymer-based CAM blocks are expected to provide guidelines for preparing accurate dental restorations.-
dc.description.statementOfResponsibilityopen-
dc.languageEnglish, Japanese-
dc.publisherJapanese Society for Dental Materials and Devices-
dc.relation.isPartOfDENTAL MATERIALS JOURNAL-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.subject.MESHCeramics-
dc.subject.MESHComputer-Aided Design-
dc.subject.MESHMaterials Testing-
dc.subject.MESHPolymers*-
dc.subject.MESHPolymethyl Methacrylate*-
dc.subject.MESHSurface Properties-
dc.titleEvaluation of the machinability and machining accuracy of polymer-based CAD/CAM blocks using merlon fracture test model-
dc.typeArticle-
dc.contributor.collegeCollege of Dentistry (치과대학)-
dc.contributor.departmentDept. of Prosthodontics (보철과학교실)-
dc.contributor.googleauthorChang-Sub Jeong-
dc.contributor.googleauthorJoon-Mo Moon-
dc.contributor.googleauthorHee-Jeong Lee-
dc.contributor.googleauthorJi-Myung Bae-
dc.contributor.googleauthorEun-Joo Choi-
dc.contributor.googleauthorSung-Tae Kim-
dc.contributor.googleauthorYoungbum Park-
dc.contributor.googleauthorSeunghan Oh-
dc.identifier.doi10.4012/dmj.2022-154-
dc.contributor.localIdA01567-
dc.relation.journalcodeJ00700-
dc.identifier.eissn1881-1361-
dc.identifier.pmid36696986-
dc.subject.keywordCAD/CAM-
dc.subject.keywordMachinability-
dc.subject.keywordMachining accuracy-
dc.subject.keywordPolymer-based CAM block-
dc.contributor.alternativeNamePark, Young Bum-
dc.contributor.affiliatedAuthor박영범-
dc.citation.volume42-
dc.citation.number2-
dc.citation.startPage273-
dc.citation.endPage281-
dc.identifier.bibliographicCitationDENTAL MATERIALS JOURNAL, Vol.42(2) : 273-281, 2023-04-
Appears in Collections:
2. College of Dentistry (치과대학) > Dept. of Prosthodontics (보철과학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.