293 588

Cited 0 times in

Cited 11 times in

European Committee on Antimicrobial Susceptibility Testing-Recommended Rapid Antimicrobial Susceptibility Testing of Escherichia coli, Klebsiella pneumoniae, and Staphylococcus aureus From Positive Blood Culture Bottles

DC Field Value Language
dc.contributor.authorPark, Jong -Min-
dc.contributor.authorKwon, Mijung-
dc.contributor.authorHong, Kiho-
dc.contributor.authorLee, Hyukmin-
dc.contributor.authorYong, Dong Eun-
dc.date.accessioned2023-08-09T06:48:58Z-
dc.date.available2023-08-09T06:48:58Z-
dc.date.created2024-01-22-
dc.date.issued2023-09-
dc.identifier.issn2234-3806-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/195969-
dc.description.abstractBackground: Early diagnosis and treatment are important for a good prognosis of blood-stream infections. The European Committee on Antimicrobial Susceptibility Testing (EU -CAST) recommends rapid antimicrobial susceptibility testing (RAST) based on the disk diffusion methodology for 4, 6, and 8 hours of incubation. We evaluated EUCAST-RAST of Escherichia coli, Klebsiella pneumoniae, and Staphylococcus aureus from positive blood culture bottles.Methods: Twenty strains of E. coli, K. pneumoniae, and S. aureus were tested using EU-CAST-RAST. Ten antimicrobial agents against E. coli and K. pneumoniae and four agents against S. aureus were tested. The diameter of the inhibition zone (mm) was compared with the minimal inhibitory concentration (mu g/mL) obtained using the Sensititre AST sys-tem (TREK Diagnostic Systems, East Grinstead, UK).Results: For E. coli, the percentage of total categorical agreement (CA) was 69.5% at 4 hours, and 87% at 8 hours. For K. pneumoniae, the total CA was 89% at 4 hours, and 95.5% at 6 hours. For S. aureus, the total CA was 100% after 4 hours. Discrepancies were observed mainly for E. coli with beta-lactam antimicrobial agents, and the numbers of errors decreased over time.Conclusions: EUCAST-RAST for K. pneumoniae and S. aureus met the United States Food and Drug Administration criteria at 6 and 4 hours, respectively, whereas that for E. coli did not meet the criteria for up to 8 hours. RAST can shorten the turn-around testing time by more than one day; therefore, if applied accurately according to laboratory conditions, an-timicrobial agent results can be reported faster.-
dc.description.statementOfResponsibilityopen-
dc.formatapplication/pdf-
dc.languageEnglish-
dc.publisherKorean Society for Laboratory Medicine-
dc.relation.isPartOfANNALS OF LABORATORY MEDICINE-
dc.relation.isPartOfANNALS OF LABORATORY MEDICINE-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.titleEuropean Committee on Antimicrobial Susceptibility Testing-Recommended Rapid Antimicrobial Susceptibility Testing of Escherichia coli, Klebsiella pneumoniae, and Staphylococcus aureus From Positive Blood Culture Bottles-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Laboratory Medicine (진단검사의학교실)-
dc.contributor.googleauthorPark, Jong -Min-
dc.contributor.googleauthorKwon, Mijung-
dc.contributor.googleauthorHong, Kiho-
dc.contributor.googleauthorLee, Hyukmin-
dc.contributor.googleauthorYong, Dong Eun-
dc.identifier.doi10.3343/alm.2023.43.5.443-
dc.relation.journalcodeJ00164-
dc.identifier.eissn2234-3814-
dc.identifier.pmid37080745-
dc.subject.keywordSepsis-
dc.subject.keywordEuropean Committee on Antimicrobial Susceptibility Testing-
dc.subject.keywordRapid antimicrobial susceptibility testing-
dc.subject.keywordMicrobial sensitivity test-
dc.subject.keywordCategorical agreement-
dc.subject.keywordUnited States Food and Drug Administration-
dc.subject.keywordEscherichia coli-
dc.subject.keywordKlebsiella pneumoniae-
dc.subject.keywordStaphylo-coccus aureus-
dc.contributor.alternativeNameYong, Dong Eun-
dc.contributor.affiliatedAuthorHong, Kiho-
dc.contributor.affiliatedAuthorLee, Hyukmin-
dc.contributor.affiliatedAuthorYong, Dong Eun-
dc.identifier.scopusid2-s2.0-85153440076-
dc.identifier.wosid000989061000007-
dc.citation.volume43-
dc.citation.number5-
dc.citation.startPage443-
dc.citation.endPage450-
dc.identifier.bibliographicCitationANNALS OF LABORATORY MEDICINE, Vol.43(5) : 443-450, 2023-09-
dc.identifier.rimsid81690-
dc.type.rimsART-
dc.description.journalClass1-
dc.description.journalClass1-
dc.subject.keywordAuthorSepsis-
dc.subject.keywordAuthorEuropean Committee on Antimicrobial Susceptibility Testing-
dc.subject.keywordAuthorRapid antimicrobial susceptibility testing-
dc.subject.keywordAuthorMicrobial sensitivity test-
dc.subject.keywordAuthorCategorical agreement-
dc.subject.keywordAuthorUnited States Food and Drug Administration-
dc.subject.keywordAuthorEscherichia coli-
dc.subject.keywordAuthorKlebsiella pneumoniae-
dc.subject.keywordAuthorStaphylo-coccus aureus-
dc.subject.keywordPlusSEPTIC SHOCK-
dc.subject.keywordPlusSEVERE SEPSIS-
dc.subject.keywordPlusPREVALENCE-
dc.subject.keywordPlusIMPACT-
dc.type.docTypeArticle-
dc.identifier.kciidART002987378-
dc.description.isOpenAccessY-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.description.journalRegisteredClasskci-
dc.relation.journalWebOfScienceCategoryMedical Laboratory Technology-
dc.relation.journalResearchAreaMedical Laboratory Technology-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Laboratory Medicine (진단검사의학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.