59 120

Cited 0 times in

척추경 나사못 삽입후 척추경 붕괴 비율에 대한 고찰

DC Field Value Language
dc.contributor.author이환모-
dc.date.accessioned2023-07-12T00:20:09Z-
dc.date.available2023-07-12T00:20:09Z-
dc.date.issued1994-06-
dc.identifier.issn1226-2102-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/195027-
dc.description.abstractPostoperative CT scans for accuracy of pedicular screw placement were assessed in 20 patients (82 pedicular screws) treated with several kinds of pedicular screws. When putting screws, the position of the guide pin was confirmed by the image intensifier. The measurement of canal encroachment from the medial border of the pedicle and the angle of insertion through the body of each vertebra were assessed; 1. Fifty-five(69.1%) were placed within the pedicle. 2. Ten(12.2%) were placed within 2mm of the medial border of the pedicle. 3. Three(3.6%) had 2mm to 6mm canal encroachment with the patient developing neurologic complication that was improved 8 months after the operation. 4.Fourteen(17.1%) perforated the lateral border of the pedicle, but they were not associated with neurologic complication. 5. The screws placed within 2mm of the medial border of the pedicle had higher angle of insertion than the screws exactly within the pedicle. Even with the use of image intensifier, there was a high rate of pedicle disruption. We have to insert the screws more exactly according to true anatomic angle of the pedicle on each level of every vertebra from the entry point avoiding high angle of insertion to prevent any disruption of the medial border of the pedicle which may result in neurologic complication.-
dc.description.statementOfResponsibilityopen-
dc.languageKorean-
dc.publisher대한정형외과학회-
dc.relation.isPartOfJournal of the Korean Orthopaedic Association(대한정형외과학회지)-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.title척추경 나사못 삽입후 척추경 붕괴 비율에 대한 고찰-
dc.title.alternativeRate of Pedicle Dissruption after Screw Fixation-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Orthopedic Surgery (정형외과학교실)-
dc.contributor.googleauthor이환모-
dc.contributor.googleauthor김남현-
dc.contributor.googleauthor이동화-
dc.contributor.localIdA03333-
dc.relation.journalcodeJ01839-
dc.identifier.eissn2005-8918-
dc.subject.keywordPedicular Screw-
dc.subject.keywordCT Scan-
dc.subject.keywordAngle of Insertion.-
dc.contributor.alternativeNameLee, Hwan Mo-
dc.contributor.affiliatedAuthor이환모-
dc.citation.volume29-
dc.citation.number3-
dc.citation.startPage972-
dc.citation.endPage978-
dc.identifier.bibliographicCitationJournal of the Korean Orthopaedic Association (대한정형외과학회지), Vol.29(3) : 972-978, 1994-06-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Orthopedic Surgery (정형외과학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.