Risk of Bacterial Exposure to the Anesthesiologist's Face During Intubation and Extubation
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 김승현 | - |
dc.contributor.author | 최승호 | - |
dc.date.accessioned | 2023-05-31T05:39:05Z | - |
dc.date.available | 2023-05-31T05:39:05Z | - |
dc.date.issued | 2023-04 | - |
dc.identifier.uri | https://ir.ymlib.yonsei.ac.kr/handle/22282913/194240 | - |
dc.description.abstract | Introduction: Anesthesiologists are exposed to the risk of infection from various secretions or droplets from the respiratory tract of patients. We aimed to determine bacterial exposure to anesthesiologists’ faces during endotracheal intubation and extubation. Methods: Six resident anesthesiologists performed 66 intubation and 66 extubation procedures in patients undergoing elective otorhinolaryngology surgeries. Sampling was performed by swabbing the face shields twice in an overlapping slalom pattern, before and after each procedure. Samples for pre-intubation and pre-extubation were collected immediately after wearing the face shield at the time of anesthesia induction and at the end of the surgery, respectively. Post-intubation samples were collected after the injection of anesthetic drugs, positive pressure mask ventilation, endotracheal intubation, and confirmation of intubation success. Post-extubation samples were collected after endotracheal tube suction, oral suction, extubation, and confirmation of spontaneous breathing and stable vital signs. All swabs were cultured for 48 h, and bacterial growth was confirmed by colony forming unit (CFU) count. Results: There was no bacterial growth in either pre- or post-intubation bacterial cultures. In contrast, while there was no bacterial growth in pre-extubation samples, 15.2% of post-extubation samples were CFU+ (0/66 [0%] vs 10/66 [15.2%], p=0.001). All the CFU+ samples belonged to 47 patients with post-extubation coughing, and the CFU count was correlated with the number of coughing episodes during the process of extubation (P < 0.01, correlation coefficient= 0.403). Conclusion: The current study shows the actual chance of bacterial exposure to the anesthesiologist’s face during the patient awakening process after general anesthesia. Given the correlation between the CFU count and the number of coughing episodes, we recommend anesthesiologists to use appropriate facial protection equipment during this procedure. | - |
dc.description.statementOfResponsibility | open | - |
dc.language | English | - |
dc.publisher | Dove Medical Press | - |
dc.relation.isPartOf | INFECTION AND DRUG RESISTANCE | - |
dc.rights | CC BY-NC-ND 2.0 KR | - |
dc.title | Risk of Bacterial Exposure to the Anesthesiologist's Face During Intubation and Extubation | - |
dc.type | Article | - |
dc.contributor.college | College of Medicine (의과대학) | - |
dc.contributor.department | Dept. of Anesthesiology and Pain Medicine (마취통증의학교실) | - |
dc.contributor.googleauthor | Sei Han Song | - |
dc.contributor.googleauthor | Seung Ho Choi | - |
dc.contributor.googleauthor | Hae Ri Park | - |
dc.contributor.googleauthor | Soo Yeon Jeon | - |
dc.contributor.googleauthor | Seung Hyun Kim | - |
dc.identifier.doi | 10.2147/idr.s405537 | - |
dc.contributor.localId | A05098 | - |
dc.contributor.localId | A04101 | - |
dc.relation.journalcode | J03958 | - |
dc.identifier.eissn | 1178-6973 | - |
dc.identifier.pmid | 37138835 | - |
dc.subject.keyword | bacterial exposure | - |
dc.subject.keyword | cough | - |
dc.subject.keyword | extubation | - |
dc.subject.keyword | face shield | - |
dc.subject.keyword | intubation | - |
dc.contributor.alternativeName | Kim, Seung Hyun | - |
dc.contributor.affiliatedAuthor | 김승현 | - |
dc.contributor.affiliatedAuthor | 최승호 | - |
dc.citation.volume | 16 | - |
dc.citation.startPage | 2433 | - |
dc.citation.endPage | 2439 | - |
dc.identifier.bibliographicCitation | INFECTION AND DRUG RESISTANCE, Vol.16 : 2433-2439, 2023-04 | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.