Cited 1 times in
Performance Evaluation of the DxC 700 AU Chemistry Analyzer in Hemoglobin A1c Measurement
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 이상국 | - |
dc.contributor.author | 임정훈 | - |
dc.contributor.author | 임종백 | - |
dc.contributor.author | 최유정 | - |
dc.contributor.author | 강혜인 | - |
dc.date.accessioned | 2023-03-22T02:31:52Z | - |
dc.date.available | 2023-03-22T02:31:52Z | - |
dc.date.issued | 2023-03 | - |
dc.identifier.issn | 2234-3806 | - |
dc.identifier.uri | https://ir.ymlib.yonsei.ac.kr/handle/22282913/193619 | - |
dc.description.abstract | Background: Accurate measurement of glycated hemoglobin (HbA1c) is crucial for a diabetes diagnosis and subsequent patient management. The detection method and presence of variant Hb can interfere with HbA1c measurements. We evaluated the HbA1c-measuring performance of the DxC 700 AU (Beckman Coulter, Brea, CA, USA) immunoassay-based device in comparison with another immunoassay device and the reference method. Methods: A total of 120 normal and 14 variant Hb samples were analyzed using the Cobas c 513 (Roche Diagnostics, Mannheim, Germany) and DxC 700 AU analyzers. Variant Hb samples were also analyzed using the reference method, along with 20 normal samples. The accuracy, precision, linearity, and carryover were determined. Results: DxC 700 AU results strongly correlated with those of Cobas c 513 and exhibited accuracy in comparison with the reference method. The within-run, between-run, between-day, and total imprecision (%CV) values for the low- and high-concentration control materials were below 2%. The results of DxC 700 AU were linear over a wide HbA1c range (3.39%-18.30%). Although DxC 700 AU performed well in the presence of variant Hb, the HbA1c concentration was underestimated in the presence of fetal Hb. The possibility of interference from a high HbH proportion could not be ruled out. Conclusions: The overall analytical performance of DxC 700 AU was acceptable. The device is accurate, precise, and linear over a wide HbA1c concentration range. Although DxC 700 AU results highly correlated with those of Cobas c 513, caution should be exercised in cases of high HbF and HbH concentrations. | - |
dc.description.statementOfResponsibility | open | - |
dc.format | application/pdf | - |
dc.language | English | - |
dc.publisher | Korean Society for Laboratory Medicine | - |
dc.relation.isPartOf | ANNALS OF LABORATORY MEDICINE | - |
dc.rights | CC BY-NC-ND 2.0 KR | - |
dc.subject.MESH | Chromatography, High Pressure Liquid | - |
dc.subject.MESH | Glycated Hemoglobin / analysis | - |
dc.subject.MESH | Hematologic Tests* | - |
dc.subject.MESH | Humans | - |
dc.subject.MESH | Immunoassay / methods | - |
dc.title | Performance Evaluation of the DxC 700 AU Chemistry Analyzer in Hemoglobin A1c Measurement | - |
dc.type | Article | - |
dc.contributor.college | College of Medicine (의과대학) | - |
dc.contributor.department | Dept. of Laboratory Medicine (진단검사의학교실) | - |
dc.contributor.googleauthor | Yu Jeong Choi | - |
dc.contributor.googleauthor | Hyein Kang | - |
dc.contributor.googleauthor | Chan-Ik Cho | - |
dc.contributor.googleauthor | John Hoon Rim | - |
dc.contributor.googleauthor | Sang-Guk Lee | - |
dc.contributor.googleauthor | Jong-Baeck Lim | - |
dc.identifier.doi | 10.3343/alm.2023.43.2.167 | - |
dc.contributor.localId | A02810 | - |
dc.contributor.localId | A04654 | - |
dc.contributor.localId | A03403 | - |
dc.relation.journalcode | J00164 | - |
dc.identifier.eissn | 2234-3814 | - |
dc.identifier.pmid | 36281510 | - |
dc.subject.keyword | Fetal hemoglobin | - |
dc.subject.keyword | Hemoglobin A1c | - |
dc.subject.keyword | Variant hemoglobin | - |
dc.contributor.alternativeName | Lee, Sang Guk | - |
dc.contributor.affiliatedAuthor | 이상국 | - |
dc.contributor.affiliatedAuthor | 임정훈 | - |
dc.contributor.affiliatedAuthor | 임종백 | - |
dc.citation.volume | 43 | - |
dc.citation.number | 2 | - |
dc.citation.startPage | 167 | - |
dc.citation.endPage | 173 | - |
dc.identifier.bibliographicCitation | ANNALS OF LABORATORY MEDICINE, Vol.43(2) : 167-173, 2023-03 | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.