0 265

Cited 11 times in

Redundant Electromagnetic Control of an Endoscopic Magnetic Capsule Driven by Multiple Electromagnets Configuration

DC Field Value Language
dc.contributor.author방승민-
dc.date.accessioned2023-03-21T07:22:02Z-
dc.date.available2023-03-21T07:22:02Z-
dc.date.issued2022-11-
dc.identifier.issn0278-0046-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/193336-
dc.description.abstractIn this article, we present a novel stationary electromagnetic actuation system (EMS) and a redundant magnetic field control approach that can enhance the magnetic actuation ability for a capsule endoscope. The EMS configured with multiple electromagnets has an intrinsic redundant problem when computing input current to each coil from inverse formulation. Here, we propose a redundant electromagnetic field control scheme of utilizing this redundancy to increase magnetic force and reduce the peak input current that deteriorates the performance. It is based on the optimization of magnetic field encountering input current and null-space equations of a pseudoinverse matrix. We validated the proposed methods in simulation and experiments through the prototyped EMS designed by considering actual human size and a magnetic capsule endoscope. The results show significant improvements in the magnetic field and lower input current compared to the conventional method as well as extended operating time through reduced heating effects. Especially, the in vitro in a gastric phantom and in vivo experiments in a live pig could prove the practical applicability of the developed method for a magnetic capsule endoscope toward upper stomach diagnosis in the clinical environment.-
dc.description.statementOfResponsibilityrestriction-
dc.languageEnglish-
dc.publisherIEEE-
dc.relation.isPartOfIEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.titleRedundant Electromagnetic Control of an Endoscopic Magnetic Capsule Driven by Multiple Electromagnets Configuration-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Internal Medicine (내과학교실)-
dc.contributor.googleauthorJayoung Kim-
dc.contributor.googleauthorHan-Sol Lee-
dc.contributor.googleauthorManh Cuong Hoang-
dc.contributor.googleauthorSeonghwan Jeong-
dc.contributor.googleauthorJae-Seung Kim-
dc.contributor.googleauthorCheong Lee-
dc.contributor.googleauthorByungjeon Kang-
dc.contributor.googleauthorJonghee Lee-
dc.contributor.googleauthorYoung-Don Son-
dc.contributor.googleauthorSeungmin Bang-
dc.contributor.googleauthorEunpyo Choi-
dc.contributor.googleauthorJong-Oh Park-
dc.contributor.googleauthorChang-Sei Kim-
dc.identifier.doi10.1109/TIE.2021.3120443-
dc.contributor.localIdA01786-
dc.relation.journalcodeJ03931-
dc.identifier.eissn1557-9948-
dc.identifier.urlhttps://ieeexplore.ieee.org/document/9583934-
dc.subject.keywordElectromagnetics-
dc.subject.keywordElectromagnets-
dc.subject.keywordMagnetic flux-
dc.subject.keywordMagnetic fields-
dc.subject.keywordMagnetic cores-
dc.subject.keywordTorque-
dc.subject.keywordEndoscopes-
dc.contributor.alternativeNameBang, Seungmin-
dc.contributor.affiliatedAuthor방승민-
dc.citation.volume69-
dc.citation.number11-
dc.citation.startPage11370-
dc.citation.endPage11382-
dc.identifier.bibliographicCitationIEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, Vol.69(11) : 11370-11382, 2022-11-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Internal Medicine (내과학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.