118 257

Cited 0 times in

TET2DICOM-GUI: Graphical User Interface Based TET2DICOM Program to Convert Tetrahedral-Mesh-Phantom to DICOM-RT Dataset

DC Field Value Language
dc.contributor.author한민철-
dc.date.accessioned2023-03-10T01:32:59Z-
dc.date.available2023-03-10T01:32:59Z-
dc.date.issued2022-12-
dc.identifier.issn2508-4445-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/193218-
dc.description.abstractRecently, tetrahedral phantoms have been newly adopted as international standard mesh-type reference computational phantoms (MRCPs) by the International Commission on Radiological Protection, and a program has been developed to convert them to computational tomography images and DICOM-RT structure files for application of radiotherapy. Through this program, the use of the tetrahedral standard phantom has become available in clinical practice, but utilization has been difficult due to various library dependencies requiring a lot of time and effort for installation. To overcome this limitation, in this study a newly developed TET2DICOM-GUI, a TET2DICOM program based on a graphical user interface (GUI), was programmed using only the MATLAB language so that it can be used without additional library installation and configuration. The program runs in the same order as TET2DICOM and has been optimized to run on a personal computer in a GUI environment. A tetrahedron-based male international standard human phantom, MRCP-AM, was used to evaluate TET2DICOM-GUI. Conversion into a DICOM-RT dataset applicable in clinical practice in about one hour with a personal computer as a basis was confirmed. Also, the generated DICOM-RT dataset was confirmed to be effectively implemented in the radiotherapy planning system. The program developed in this study is expected to replace actual patient data in future studies.-
dc.description.statementOfResponsibilityopen-
dc.languageEnglish-
dc.publisherKorean Society of Medical Physics-
dc.relation.isPartOfProgress in Medical Physics-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.titleTET2DICOM-GUI: Graphical User Interface Based TET2DICOM Program to Convert Tetrahedral-Mesh-Phantom to DICOM-RT Dataset-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Radiation Oncology (방사선종양학교실)-
dc.contributor.googleauthorSe Hyung Lee-
dc.contributor.googleauthorBo-Wi Cheon-
dc.contributor.googleauthorChul Hee Min-
dc.contributor.googleauthorHaegin Han-
dc.contributor.googleauthorChan Hyeong Kim-
dc.contributor.googleauthorMin Cheol Han-
dc.contributor.googleauthorSeonghoon Kim-
dc.identifier.doi10.14316/pmp.2022.33.4.172-
dc.contributor.localIdA05870-
dc.relation.journalcodeJ03591-
dc.identifier.eissn2508-4453-
dc.subject.keywordTetrahedral-mesh phantom-
dc.subject.keywordDICOM-
dc.subject.keywordVoxelization-
dc.subject.keywordComputational tomography-
dc.subject.keywordRT structure-
dc.contributor.alternativeNameHan, Min Cheol-
dc.contributor.affiliatedAuthor한민철-
dc.citation.volume33-
dc.citation.number4-
dc.citation.startPage172-
dc.citation.endPage179-
dc.identifier.bibliographicCitationProgress in Medical Physics, Vol.33(4) : 172-179, 2022-12-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Radiation Oncology (방사선종양학교실) > 1. Journal Papers

qrcode