Dead Layer Thickness and Geometry Optimization of HPGe Detector Based on Monte Carlo Simulation

DC Field Value Language
dc.contributor.author김동욱-
dc.date.accessioned2023-03-10T01:24:04Z-
dc.date.available2023-03-10T01:24:04Z-
dc.date.issued2022-12-
dc.identifier.issn2508-4445-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/193149-
dc.description.abstractPurpose: A full-energy-peak (FEP) efficiency correction is required through a Monte Carlo simulation for accurate radioactivity measurement, considering the geometrical characteristics of the detector and the sample. However, a relative deviation (RD) occurs between the measurement and calculation efficiencies when modeling using the data provided by the manufacturers due to the randomly generated dead layer. This study aims to optimize the structure of the detector by determining the dead layer thickness based on Monte Carlo simulation. Methods: The high-purity germanium (HPGe) detector used in this study was a coaxial p-type GC2518 model, and a certified reference material (CRM) was used to measure the FEP efficiency. Using the MC N-Particle Transport Code (MCNP) code, the FEP efficiency was calculated by increasing the thickness of the outer and inner dead layer in proportion to the thickness of the electrode. Results: As the thickness of the outer and inner dead layer increased by 0.1 mm and 0.1 µm, the efficiency difference decreased by 2.43% on average up to 1.0 mm and 1.0 µm and increased by 1.86% thereafter. Therefore, the structure of the detector was optimized by determining 1.0 mm and 1.0 µm as thickness of the dead layer. Conclusions: The effect of the dead layer on the FEP efficiency was evaluated, and an excellent agreement between the measured and calculated efficiencies was confirmed with RDs of less than 4%. It suggests that the optimized HPGe detector can be used to measure the accurate radioactivity using in dismantling and disposing medical linear accelerators.-
dc.description.statementOfResponsibilityopen-
dc.formatapplication/pdf-
dc.languageEnglish-
dc.publisherKorean Society of Medical Physics-
dc.relation.isPartOfProgress in Medical Physics-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.titleDead Layer Thickness and Geometry Optimization of HPGe Detector Based on Monte Carlo Simulation-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Radiation Oncology (방사선종양학교실)-
dc.contributor.googleauthorSuah Yu-
dc.contributor.googleauthorNa Hye Kwon-
dc.contributor.googleauthorYoung Jae Jang-
dc.contributor.googleauthorByungchae Lee-
dc.contributor.googleauthorJihyun Yu-
dc.contributor.googleauthorDong-Wook Kim-
dc.contributor.googleauthorGyu-Seok Cho-
dc.contributor.googleauthorKum-Bae Kim-
dc.contributor.googleauthorGeun Beom Kim-
dc.contributor.googleauthorCheol Ha Baek-
dc.contributor.googleauthorSang Hyoun Choi-
dc.identifier.doi10.14316/pmp.2022.33.4.129-
dc.contributor.localIdA05710-
dc.relation.journalcodeJ03591-
dc.identifier.eissn2508-4453-
dc.subject.keywordHPGe detector-
dc.subject.keywordDead layer-
dc.subject.keywordMonte Carlo simulation-
dc.subject.keywordFull-energy-peak efficiency-
dc.contributor.alternativeNameKim, Dong Wook-
dc.contributor.affiliatedAuthor김동욱-
dc.citation.volume33-
dc.citation.number4-
dc.citation.startPage129-
dc.citation.endPage135-
dc.identifier.bibliographicCitationProgress in Medical Physics, Vol.33(4) : 129-135, 2022-12-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Radiation Oncology (방사선종양학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.