Cited 0 times in 
Cited 62 times in 
Wireless Non-Invasive Monitoring of Cholesterol Using a Smart Contact Lens
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Song, Hayoung | - |
| dc.contributor.author | Shin, Haein | - |
| dc.contributor.author | Seo, Hunkyu | - |
| dc.contributor.author | Park, Wonjung | - |
| dc.contributor.author | Joo, Byung Jun | - |
| dc.contributor.author | Kim, Jeongho | - |
| dc.contributor.author | Kim, Jeonghyun | - |
| dc.contributor.author | Kim, Hong Kyun | - |
| dc.contributor.author | Kim, Jayoung | - |
| dc.contributor.author | Park, Jang-Ung | - |
| dc.date.accessioned | 2022-12-22T04:31:02Z | - |
| dc.date.available | 2022-12-22T04:31:02Z | - |
| dc.date.created | 2023-01-27 | - |
| dc.date.issued | 2022-10 | - |
| dc.identifier.issn | * | - |
| dc.identifier.uri | https://ir.ymlib.yonsei.ac.kr/handle/22282913/192154 | - |
| dc.description.abstract | Herein, a wireless and soft smart contact lens that enables real-time quantitative recording of cholesterol in tear fluids for the monitoring of patients with hyperlipidemia using a smartphone is reported. This contact lens incorporates an electrochemical biosensor for the continuous detection of cholesterol concentrations, stretchable antenna, and integrated circuits for wireless communication, which makes a smartphone the only device required to operate this lens remotely without obstructing the wearer's vision. The hyperlipidemia rabbit model is utilized to confirm the correlation between cholesterol levels in tear fluid and blood and to confirm the feasibility of this smart contact lens for diagnostic application of cholesterol-related diseases. Further in vivo tests with human subjects demonstrated its good biocompatibility, wearability, and reliability as a non-invasive healthcare device. | - |
| dc.description.statementOfResponsibility | open | - |
| dc.language | English | - |
| dc.publisher | WILEY-VCH | - |
| dc.relation.isPartOf | ADVANCED SCIENCE | - |
| dc.relation.isPartOf | ADVANCED SCIENCE | - |
| dc.rights | CC BY-NC-ND 2.0 KR | - |
| dc.title | Wireless Non-Invasive Monitoring of Cholesterol Using a Smart Contact Lens | - |
| dc.type | Article | - |
| dc.contributor.college | College of Medicine (의과대학) | - |
| dc.contributor.department | Dept. of Medical Engineering (의학공학교실) | - |
| dc.contributor.googleauthor | Song, Hayoung | - |
| dc.contributor.googleauthor | Shin, Haein | - |
| dc.contributor.googleauthor | Seo, Hunkyu | - |
| dc.contributor.googleauthor | Park, Wonjung | - |
| dc.contributor.googleauthor | Joo, Byung Jun | - |
| dc.contributor.googleauthor | Kim, Jeongho | - |
| dc.contributor.googleauthor | Kim, Jeonghyun | - |
| dc.contributor.googleauthor | Kim, Hong Kyun | - |
| dc.contributor.googleauthor | Kim, Jayoung | - |
| dc.contributor.googleauthor | Park, Jang-Ung | - |
| dc.identifier.doi | 10.1002/advs.202203597 | - |
| dc.relation.journalcode | J04017 | - |
| dc.identifier.eissn | 2198-3844 | - |
| dc.identifier.pmid | 35975449 | - |
| dc.subject.keyword | cholesterol | - |
| dc.subject.keyword | healthcare device | - |
| dc.subject.keyword | smart contact lens | - |
| dc.subject.keyword | stretchable antenna | - |
| dc.subject.keyword | wireless communication | - |
| dc.contributor.alternativeName | Kim, Jayoung | - |
| dc.contributor.affiliatedAuthor | Kim, Jayoung | - |
| dc.identifier.scopusid | 2-s2.0-85135942027 | - |
| dc.identifier.wosid | 000841132500001 | - |
| dc.citation.volume | 9 | - |
| dc.citation.number | 28 | - |
| dc.identifier.bibliographicCitation | ADVANCED SCIENCE, Vol.9(28), 2022-10 | - |
| dc.identifier.rimsid | 77290 | - |
| dc.type.rims | ART | - |
| dc.description.journalClass | 1 | - |
| dc.description.journalClass | 1 | - |
| dc.subject.keywordAuthor | cholesterol | - |
| dc.subject.keywordAuthor | healthcare device | - |
| dc.subject.keywordAuthor | smart contact lens | - |
| dc.subject.keywordAuthor | stretchable antenna | - |
| dc.subject.keywordAuthor | wireless communication | - |
| dc.subject.keywordPlus | TEAR GLUCOSE | - |
| dc.subject.keywordPlus | DEVICES | - |
| dc.subject.keywordPlus | SENSOR | - |
| dc.subject.keywordPlus | HEALTH | - |
| dc.type.docType | Article | - |
| dc.description.isOpenAccess | Y | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.relation.journalWebOfScienceCategory | Chemistry, Multidisciplinary | - |
| dc.relation.journalWebOfScienceCategory | Nanoscience & Nanotechnology | - |
| dc.relation.journalWebOfScienceCategory | Materials Science, Multidisciplinary | - |
| dc.relation.journalResearchArea | Chemistry | - |
| dc.relation.journalResearchArea | Science & Technology - Other Topics | - |
| dc.relation.journalResearchArea | Materials Science | - |
| dc.identifier.articleno | 2203597 | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.