0 442

Cited 0 times in

Cited 1 times in

Geant4 electromagnetic physics model assessment for RBE-weighted dose calculation of carbon-ion radiotherapy

DC Field Value Language
dc.contributor.authorKang, Hyo Kyeong-
dc.contributor.authorHan, Min Cheol-
dc.contributor.authorYun, Yongdo-
dc.contributor.authorLee, Se Hyung-
dc.contributor.authorKim, Chan Hyeong-
dc.contributor.authorKim, Jin Sung-
dc.date.accessioned2022-12-22T03:25:38Z-
dc.date.available2022-12-22T03:25:38Z-
dc.date.created2023-01-27-
dc.date.issued2022-12-
dc.identifier.issn0374-4884-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/191874-
dc.description.abstractCarbon-ion radiotherapy (CIRT) is being increasingly practiced owing to its advantages over conventional photon-based radiotherapy. Several CIRT-related dose calculation studies considering the biological effects of carbon ions were performed using the Geant4 Monte Carlo toolkit. For accurate RBE-weighted dose calculation in CIRT, the Geant4 physics models used in a simulation code need to be validated. Previous studies have validated the hadronic physics model of Geant4, but a validation study for electromagnetic (EM) physics models is missing. Therefore, we validated the Geant4 EM physics models for carbon RBE-weighted dose calculation. For the validation process in Geant4, the geometry used in the Microdosimetric kinetic model was irradiated by mono-energy beams between 0.1 and 1000 MeV/u of six elements (H, He, Li, Be, B, and C). The imparted dose calculated using various EM physics models is compared with the theoretical value. A G4EMStandardPhysics-based model is confirmed to result in breaking points for RBE-weighted dose calculations, whereas no such breaking points are observed when using our physics model and Geant4-DNA physics model. Because the breaking points observed in the results may induce uncorrected dose calculations, validating the EM physics models is recommended when performing carbon RBE-weighted dose calculation using Geant4.-
dc.description.statementOfResponsibilityrestriction-
dc.languageEnglish-
dc.publisherKorean Physical Society-
dc.relation.isPartOfJOURNAL OF THE KOREAN PHYSICAL SOCIETY-
dc.relation.isPartOfJOURNAL OF THE KOREAN PHYSICAL SOCIETY-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.titleGeant4 electromagnetic physics model assessment for RBE-weighted dose calculation of carbon-ion radiotherapy-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Radiation Oncology (방사선종양학교실)-
dc.contributor.googleauthorKang, Hyo Kyeong-
dc.contributor.googleauthorHan, Min Cheol-
dc.contributor.googleauthorYun, Yongdo-
dc.contributor.googleauthorLee, Se Hyung-
dc.contributor.googleauthorKim, Chan Hyeong-
dc.contributor.googleauthorKim, Jin Sung-
dc.identifier.doi10.1007/s40042-022-00568-x-
dc.relation.journalcodeJ02927-
dc.subject.keywordCarbon-ion radiotherapy-
dc.subject.keywordRelative biological effectiveness-
dc.subject.keywordElectromagnetic physics model-
dc.subject.keywordGeant4-
dc.subject.keywordMicrodosimetry kinetic model-
dc.contributor.alternativeNameKim, Jinsung-
dc.contributor.affiliatedAuthorKang, Hyo Kyeong-
dc.contributor.affiliatedAuthorHan, Min Cheol-
dc.contributor.affiliatedAuthorYun, Yongdo-
dc.contributor.affiliatedAuthorKim, Jin Sung-
dc.identifier.scopusid2-s2.0-85135696227-
dc.identifier.wosid000837535700002-
dc.citation.volume81-
dc.citation.number11-
dc.citation.startPage1059-
dc.citation.endPage1063-
dc.identifier.bibliographicCitationJOURNAL OF THE KOREAN PHYSICAL SOCIETY, Vol.81(11) : 1059-1063, 2022-12-
dc.identifier.rimsid77308-
dc.type.rimsART-
dc.description.journalClass1-
dc.description.journalClass1-
dc.subject.keywordAuthorCarbon-ion radiotherapy-
dc.subject.keywordAuthorRelative biological effectiveness-
dc.subject.keywordAuthorElectromagnetic physics model-
dc.subject.keywordAuthorGeant4-
dc.subject.keywordAuthorMicrodosimetry kinetic model-
dc.subject.keywordPlusSIMULATION-
dc.subject.keywordPlusVALIDATION-
dc.subject.keywordPlusPLATFORM-
dc.subject.keywordPlusTHERAPY-
dc.subject.keywordPlusTOPAS-
dc.type.docTypeArticle-
dc.identifier.kciidART002904374-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.description.journalRegisteredClasskci-
dc.relation.journalWebOfScienceCategoryPhysics, Multidisciplinary-
dc.relation.journalResearchAreaPhysics-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Radiation Oncology (방사선종양학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.