Cited 0 times in 
Cited 1 times in 
Geant4 electromagnetic physics model assessment for RBE-weighted dose calculation of carbon-ion radiotherapy
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Kang, Hyo Kyeong | - |
| dc.contributor.author | Han, Min Cheol | - |
| dc.contributor.author | Yun, Yongdo | - |
| dc.contributor.author | Lee, Se Hyung | - |
| dc.contributor.author | Kim, Chan Hyeong | - |
| dc.contributor.author | Kim, Jin Sung | - |
| dc.date.accessioned | 2022-12-22T03:25:38Z | - |
| dc.date.available | 2022-12-22T03:25:38Z | - |
| dc.date.created | 2023-01-27 | - |
| dc.date.issued | 2022-12 | - |
| dc.identifier.issn | 0374-4884 | - |
| dc.identifier.uri | https://ir.ymlib.yonsei.ac.kr/handle/22282913/191874 | - |
| dc.description.abstract | Carbon-ion radiotherapy (CIRT) is being increasingly practiced owing to its advantages over conventional photon-based radiotherapy. Several CIRT-related dose calculation studies considering the biological effects of carbon ions were performed using the Geant4 Monte Carlo toolkit. For accurate RBE-weighted dose calculation in CIRT, the Geant4 physics models used in a simulation code need to be validated. Previous studies have validated the hadronic physics model of Geant4, but a validation study for electromagnetic (EM) physics models is missing. Therefore, we validated the Geant4 EM physics models for carbon RBE-weighted dose calculation. For the validation process in Geant4, the geometry used in the Microdosimetric kinetic model was irradiated by mono-energy beams between 0.1 and 1000 MeV/u of six elements (H, He, Li, Be, B, and C). The imparted dose calculated using various EM physics models is compared with the theoretical value. A G4EMStandardPhysics-based model is confirmed to result in breaking points for RBE-weighted dose calculations, whereas no such breaking points are observed when using our physics model and Geant4-DNA physics model. Because the breaking points observed in the results may induce uncorrected dose calculations, validating the EM physics models is recommended when performing carbon RBE-weighted dose calculation using Geant4. | - |
| dc.description.statementOfResponsibility | restriction | - |
| dc.language | English | - |
| dc.publisher | Korean Physical Society | - |
| dc.relation.isPartOf | JOURNAL OF THE KOREAN PHYSICAL SOCIETY | - |
| dc.relation.isPartOf | JOURNAL OF THE KOREAN PHYSICAL SOCIETY | - |
| dc.rights | CC BY-NC-ND 2.0 KR | - |
| dc.title | Geant4 electromagnetic physics model assessment for RBE-weighted dose calculation of carbon-ion radiotherapy | - |
| dc.type | Article | - |
| dc.contributor.college | College of Medicine (의과대학) | - |
| dc.contributor.department | Dept. of Radiation Oncology (방사선종양학교실) | - |
| dc.contributor.googleauthor | Kang, Hyo Kyeong | - |
| dc.contributor.googleauthor | Han, Min Cheol | - |
| dc.contributor.googleauthor | Yun, Yongdo | - |
| dc.contributor.googleauthor | Lee, Se Hyung | - |
| dc.contributor.googleauthor | Kim, Chan Hyeong | - |
| dc.contributor.googleauthor | Kim, Jin Sung | - |
| dc.identifier.doi | 10.1007/s40042-022-00568-x | - |
| dc.relation.journalcode | J02927 | - |
| dc.subject.keyword | Carbon-ion radiotherapy | - |
| dc.subject.keyword | Relative biological effectiveness | - |
| dc.subject.keyword | Electromagnetic physics model | - |
| dc.subject.keyword | Geant4 | - |
| dc.subject.keyword | Microdosimetry kinetic model | - |
| dc.contributor.alternativeName | Kim, Jinsung | - |
| dc.contributor.affiliatedAuthor | Kang, Hyo Kyeong | - |
| dc.contributor.affiliatedAuthor | Han, Min Cheol | - |
| dc.contributor.affiliatedAuthor | Yun, Yongdo | - |
| dc.contributor.affiliatedAuthor | Kim, Jin Sung | - |
| dc.identifier.scopusid | 2-s2.0-85135696227 | - |
| dc.identifier.wosid | 000837535700002 | - |
| dc.citation.volume | 81 | - |
| dc.citation.number | 11 | - |
| dc.citation.startPage | 1059 | - |
| dc.citation.endPage | 1063 | - |
| dc.identifier.bibliographicCitation | JOURNAL OF THE KOREAN PHYSICAL SOCIETY, Vol.81(11) : 1059-1063, 2022-12 | - |
| dc.identifier.rimsid | 77308 | - |
| dc.type.rims | ART | - |
| dc.description.journalClass | 1 | - |
| dc.description.journalClass | 1 | - |
| dc.subject.keywordAuthor | Carbon-ion radiotherapy | - |
| dc.subject.keywordAuthor | Relative biological effectiveness | - |
| dc.subject.keywordAuthor | Electromagnetic physics model | - |
| dc.subject.keywordAuthor | Geant4 | - |
| dc.subject.keywordAuthor | Microdosimetry kinetic model | - |
| dc.subject.keywordPlus | SIMULATION | - |
| dc.subject.keywordPlus | VALIDATION | - |
| dc.subject.keywordPlus | PLATFORM | - |
| dc.subject.keywordPlus | THERAPY | - |
| dc.subject.keywordPlus | TOPAS | - |
| dc.type.docType | Article | - |
| dc.identifier.kciid | ART002904374 | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.relation.journalWebOfScienceCategory | Physics, Multidisciplinary | - |
| dc.relation.journalResearchArea | Physics | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.