238 568

Cited 0 times in

Cited 5 times in

Substantial Improvement in Nontuberculous Mycobacterial Identification Using ASTA MicroIDSys Matrix-Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry with an Upgraded Database

DC Field Value Language
dc.contributor.authorSong, Junhyup-
dc.contributor.authorYoon, Shinyoung-
dc.contributor.authorIn, Yongha-
dc.contributor.authorKim, Daewon-
dc.contributor.authorLee, Hyukmin-
dc.contributor.authorYong, Dong Eun-
dc.contributor.authorLee, Kyung won-
dc.date.accessioned2022-12-22T01:58:25Z-
dc.date.available2022-12-22T01:58:25Z-
dc.date.created2023-01-19-
dc.date.issued2022-05-
dc.identifier.issn2234-3806-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/191406-
dc.description.abstractIdentifying Mycobacterium using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) is challenging. We evaluated the performance of MALDI-TOF MS in identifying nontuberculous mycobacteria (NTM) using the ASTA MicroIDSys system (ASTA Inc., Suwon, Korea) with the MycoDB v1.95s and upgraded MycoDB v2.0-beta databases. We tested 124 NTM isolates collected from Ogawa medium at Severance Hospital, Seoul, Korea, between January and April 2019. MicroIDSys scores were categorized into three groups: >= 140, reliable identification; 130-139, ambiguous identification; and <130, invalid identification. To validate the results, we used the reverse blot hybridization assay (Molecutech REBA MycoID, YD Diagnostics Corp., Korea). Initial analysis using MycoDB v1.95s resulted in 26.6% (33/124) reliable, 43.5% (54/124) ambiguous, and 29.8% (37/124) invalid identifications. Re-analysis using the upgraded MycoDB v2.0-beta database resulted in 94.4% (117/124) reliable, 4.0% (5/124) ambiguous, and 1.6% invalid (2/124) identifications. The percentage of reliable identifications that matched with the reference increased from 26.6% (33/124) with MycoDB v1.95s to 93.5% (116/124) with MycoDB v2.0-beta. The upgraded databases enable substantially improved NTM identification through deep learning in the inference algorithm and by considering more axes in the correlation analysis. MALDI-TOF MS using the upgraded database unambiguously identified most NTM species. Our study lays a foundation for applying MALDITOF MS for the simple and rapid identification of NTM isolated from solid media.-
dc.description.statementOfResponsibilityopen-
dc.formatapplication/pdf-
dc.languageEnglish-
dc.publisherKorean Society for Laboratory Medicine-
dc.relation.isPartOfAnnals of Laboratory Medicine-
dc.relation.isPartOfANNALS OF LABORATORY MEDICINE-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.titleSubstantial Improvement in Nontuberculous Mycobacterial Identification Using ASTA MicroIDSys Matrix-Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry with an Upgraded Database-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Laboratory Medicine (진단검사의학교실)-
dc.contributor.googleauthorSong, Junhyup-
dc.contributor.googleauthorYoon, Shinyoung-
dc.contributor.googleauthorIn, Yongha-
dc.contributor.googleauthorKim, Daewon-
dc.contributor.googleauthorLee, Hyukmin-
dc.contributor.googleauthorYong, Dong Eun-
dc.contributor.googleauthorLee, Kyung won-
dc.identifier.doi10.3343/alm.2022.42.3.358-
dc.relation.journalcodeJ00164-
dc.identifier.eissn2234-3814-
dc.identifier.pmid34907106-
dc.subject.keywordMatrix-assisted laser desorption-
dc.subject.keywordionization time-of-flight mass spectrometry-
dc.subject.keywordNontuberculous mycobacteria-
dc.subject.keywordDatabase upgrade-
dc.subject.keywordIdentification-
dc.subject.keywordPerformance evaluation-
dc.contributor.alternativeNameYong, Dong Eun-
dc.contributor.affiliatedAuthorSong, Junhyup-
dc.contributor.affiliatedAuthorYoon, Shinyoung-
dc.contributor.affiliatedAuthorLee, Hyukmin-
dc.contributor.affiliatedAuthorYong, Dong Eun-
dc.contributor.affiliatedAuthorLee, Kyung won-
dc.identifier.scopusid2-s2.0-85122623281-
dc.identifier.wosid000737636900008-
dc.citation.volume42-
dc.citation.number3-
dc.citation.startPage358-
dc.citation.endPage362-
dc.identifier.bibliographicCitationAnnals of Laboratory Medicine, Vol.42(3) : 358-362, 2022-05-
dc.identifier.rimsid76741-
dc.type.rimsART-
dc.description.journalClass1-
dc.description.journalClass1-
dc.subject.keywordAuthorMatrix-assisted laser desorption-
dc.subject.keywordAuthorionization time-of-flight mass spectrometry-
dc.subject.keywordAuthorNontuberculous mycobacteria-
dc.subject.keywordAuthorDatabase upgrade-
dc.subject.keywordAuthorIdentification-
dc.subject.keywordAuthorPerformance evaluation-
dc.subject.keywordPlusDESORPTION IONIZATION-TIME-
dc.subject.keywordPlusMALDI-TOF MS-
dc.subject.keywordPlusBIOTYPER-
dc.subject.keywordPlusCULTURES-
dc.subject.keywordPlusIMPACT-
dc.type.docTypeArticle-
dc.identifier.kciidART002832434-
dc.description.isOpenAccessY-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.description.journalRegisteredClasskci-
dc.relation.journalWebOfScienceCategoryMedical Laboratory Technology-
dc.relation.journalResearchAreaMedical Laboratory Technology-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Laboratory Medicine (진단검사의학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.