Cited 4 times in
Efficacy and Safety of TJP-008 Compared to 2 L PEG with Ascorbate in Colon Cleansing: A Randomized Phase 3 Trial
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 김태일 | - |
dc.date.accessioned | 2022-12-22T01:39:37Z | - |
dc.date.available | 2022-12-22T01:39:37Z | - |
dc.date.issued | 2022-03 | - |
dc.identifier.issn | 1976-2283 | - |
dc.identifier.uri | https://ir.ymlib.yonsei.ac.kr/handle/22282913/191285 | - |
dc.description.abstract | Background/aims: Polyethylene glycol (PEG)-based bowel preparations are effective cleansing agents for colonoscopy. However, they require relatively large volumes to be used even with agents such as 2 L PEG with ascorbate (2LPEG). This phase 3, randomized, single-blinded, multicenter, parallel-group study compared the efficacy of 1 L PEG with high-dose ascorbate, TJP-008, to 2LPEG. Methods: Patients undergoing colonoscopy were randomized (1:1:1) to receive TJP-008 as 1-day split dose (TJP-008-1) or 2-day split dose (TJP-008-2) regimen or to receive 2LPEG as a 2-day split dose regimen. Cleansing efficacy was evaluated using the Harefield Cleansing Scale. The primary endpoint was overall bowel cleansing success. Full analysis set (FAS) and per protocol set (PPS) analyses were performed. Results: Of the 314 screened patients, efficacy was assessed in the following patient numbers (FAS/PPS): total (293/285), TJP-008-1 (98/94), TJP-008-2 (97/95), and 2LPEG (98/96). FAS revealed noninferiority between TJP-008 and 2LPEG with regard to overall success (TJP-008-2, 99.0%; TJP-008-1, 95.9%; 2LPEG, 94.9%; p=0.100 and p=0.733, respectively). PPS also showed noninferiority (p=0.721 and p=0.211, respectively). However, the PPS analyses showed a higher bowel cleansing score for TJP-008-2 for high-quality cleansing in the right colon (TJP-008-2 83.2% vs 2LPEG 62.5%; p=0.005). Conclusions: TJP-008 is a new low-volume cleansing agent with a colon cleansing efficacy comparable to that of standard 2LPEG that exhibits significant safety and tolerability. | - |
dc.description.statementOfResponsibility | open | - |
dc.language | English | - |
dc.publisher | Editorial Office of Gut and Liver | - |
dc.relation.isPartOf | GUT AND LIVER | - |
dc.rights | CC BY-NC-ND 2.0 KR | - |
dc.subject.MESH | Ascorbic Acid | - |
dc.subject.MESH | Cathartics* | - |
dc.subject.MESH | Colon | - |
dc.subject.MESH | Colonoscopy / methods | - |
dc.subject.MESH | Humans | - |
dc.subject.MESH | Polyethylene Glycols* | - |
dc.title | Efficacy and Safety of TJP-008 Compared to 2 L PEG with Ascorbate in Colon Cleansing: A Randomized Phase 3 Trial | - |
dc.type | Article | - |
dc.contributor.college | College of Medicine (의과대학) | - |
dc.contributor.department | Dept. of Internal Medicine (내과학교실) | - |
dc.contributor.googleauthor | Ja Seol Koo | - |
dc.contributor.googleauthor | Jeong-Sik Byeon | - |
dc.contributor.googleauthor | Bo-In Lee | - |
dc.contributor.googleauthor | Sung-Ae Jung | - |
dc.contributor.googleauthor | Tae Il Kim | - |
dc.contributor.googleauthor | Yoon Tae Jeen | - |
dc.identifier.doi | 10.5009/GNL210092 | - |
dc.contributor.localId | A01079 | - |
dc.relation.journalcode | J00954 | - |
dc.identifier.eissn | 2005-1212 | - |
dc.identifier.pmid | 34810296 | - |
dc.subject.keyword | Ascorbic acid | - |
dc.subject.keyword | Cathartics | - |
dc.subject.keyword | Colonoscopy | - |
dc.subject.keyword | Polyethylene glycols | - |
dc.subject.keyword | Safety | - |
dc.contributor.alternativeName | Kim, Tae Il | - |
dc.contributor.affiliatedAuthor | 김태일 | - |
dc.citation.volume | 16 | - |
dc.citation.number | 2 | - |
dc.citation.startPage | 259 | - |
dc.citation.endPage | 268 | - |
dc.identifier.bibliographicCitation | GUT AND LIVER, Vol.16(2) : 259-268, 2022-03 | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.