Cited 5 times in
Reference based simulation study of detector comparison for BNCT-SPECT imaging
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 신한백 | - |
dc.date.accessioned | 2022-09-06T06:43:59Z | - |
dc.date.available | 2022-09-06T06:43:59Z | - |
dc.date.issued | 2020-01 | - |
dc.identifier.issn | 1738-5733 | - |
dc.identifier.uri | https://ir.ymlib.yonsei.ac.kr/handle/22282913/190298 | - |
dc.description.abstract | To investigate the optimal detector material for prompt gamma imaging during boron neutron capture therapy, in this study, we evaluated the characteristic regarding radiation reaction of available detector materials using a Monte Carlo simulation. Sixteen detector materials used for radiation detection were investigated to assess their advantages and drawbacks. The estimations used previous experimental data to build the simulation codes. The energy resolution and detection efficiency of each material was investigated, and prompt gamma images during BNCT simulation were acquired using only the detectors that showed good performance in our preliminary data. From the simulation, we could evaluate the majority of detector materials in BNCT and also could acquire a prompt gamma image using the six high ranked-detector materials and lutetium yttrium oxyorthosilicate. We provide a strategy to select an optimal detector material for the prompt gamma imaging during BNCT with three conclusions. | - |
dc.description.statementOfResponsibility | restriction | - |
dc.language | English | - |
dc.publisher | Korea Nuclear Society | - |
dc.relation.isPartOf | NUCLEAR ENGINEERING AND TECHNOLOGY | - |
dc.rights | CC BY-NC-ND 2.0 KR | - |
dc.title | Reference based simulation study of detector comparison for BNCT-SPECT imaging | - |
dc.type | Article | - |
dc.contributor.college | College of Medicine (의과대학) | - |
dc.contributor.department | Dept. of Radiation Oncology (방사선종양학교실) | - |
dc.contributor.googleauthor | Moo-Sub Kim | - |
dc.contributor.googleauthor | Han-Back Shin | - |
dc.contributor.googleauthor | Min-Geon Choi | - |
dc.contributor.googleauthor | Hajime Monzen | - |
dc.contributor.googleauthor | Jae Goo Shim | - |
dc.contributor.googleauthor | Tae Suk Suh | - |
dc.contributor.googleauthor | Do-Kun Yoon | - |
dc.identifier.doi | 10.1016/j.net.2019.07.002 | - |
dc.contributor.localId | A06229 | - |
dc.relation.journalcode | J03972 | - |
dc.identifier.url | https://www.sciencedirect.com/science/article/pii/S1738573319303146 | - |
dc.subject.keyword | Boron neutron capture therapy (BNCT) | - |
dc.subject.keyword | Prompt gamma | - |
dc.subject.keyword | Detector materials | - |
dc.subject.keyword | Monte Carlo simulation | - |
dc.contributor.alternativeName | Shin, Han-Back | - |
dc.contributor.affiliatedAuthor | 신한백 | - |
dc.citation.volume | 52 | - |
dc.citation.number | 1 | - |
dc.citation.startPage | 155 | - |
dc.citation.endPage | 163 | - |
dc.identifier.bibliographicCitation | NUCLEAR ENGINEERING AND TECHNOLOGY, Vol.52(1) : 155-163, 2020-01 | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.