0 333

Cited 8 times in

Influence of adjacent teeth on the accuracy of intraoral scanning systems for class II inlay preparation

DC Field Value Language
dc.contributor.author이현종-
dc.date.accessioned2022-08-23T00:43:58Z-
dc.date.available2022-08-23T00:43:58Z-
dc.date.issued2022-07-
dc.identifier.issn1496-4155-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/189592-
dc.description.abstractObjective: This study aimed to evaluate the influence of the presence of adjacent teeth on the accuracy of intraoral scanning (IOS) systems for class II inlay preparation. Materials and methods: The mesio-occlusal inlay preparation was prepared in an anatomical model of the maxillary molar. The prepared tooth was secured to a typodont with the mesial adjacent tooth removed or in situ. Ten digital impressions of the inlay preparation were acquired using three IOS systems (CEREC Primescan, 3Shape TRIOS 3, and Medit i500). A laboratory scanner (3Shape E3) was used to obtain the reference scan data. The mean absolute deviation values were calculated to evaluate the accuracy of the digital models. Results: The group with the adjacent teeth present showed lower trueness and precision compared to that without the adjacent tooth (p < .05). Significant differences were observed among the IOS systems (p < .05). Primescan showed the highest accuracy, irrespective of the presence of adjacent teeth. Conclusions: The presence of the adjacent tooth negatively affected the accuracy of all the IOSs tested. Although the performance of Primescan was superior to that of TRIOS 3 and i500, each IOS system showed clinically acceptable levels of accuracy for class II inlay preparation. Clinical significance: The adjacent tooth can be a confounding factor for accurate digital impressions of class II inlay preparation.-
dc.description.statementOfResponsibilityrestriction-
dc.languageEnglish-
dc.publisherWiley-Blackwell-
dc.relation.isPartOfJOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.subject.MESHComputer-Aided Design-
dc.subject.MESHDental Arch-
dc.subject.MESHDental Impression Technique*-
dc.subject.MESHImaging, Three-Dimensional-
dc.subject.MESHInlays-
dc.subject.MESHModels, Dental*-
dc.titleInfluence of adjacent teeth on the accuracy of intraoral scanning systems for class II inlay preparation-
dc.typeArticle-
dc.contributor.collegeCollege of Dentistry (치과대학)-
dc.contributor.departmentDept. of Prosthodontics (보철과학교실)-
dc.contributor.googleauthorJae-Hoon Kim-
dc.contributor.googleauthorSung-Ae Son-
dc.contributor.googleauthorHyeonjong Lee-
dc.contributor.googleauthorYeon-Jee Yoo-
dc.contributor.googleauthorSeoung-Jin Hong-
dc.contributor.googleauthorJeong-Kil Park-
dc.identifier.doi10.1111/jerd.12824-
dc.contributor.localIdA06238-
dc.relation.journalcodeJ04183-
dc.identifier.eissn1708-8240-
dc.identifier.pmid34608739-
dc.identifier.urlhttps://onlinelibrary.wiley.com/doi/10.1111/jerd.12824-
dc.subject.keyword3D comparison-
dc.subject.keyworddigital impression-
dc.subject.keywordinlay preparation-
dc.subject.keywordintraoral scanner-
dc.contributor.alternativeNameLee, Hyeonjong-
dc.contributor.affiliatedAuthor이현종-
dc.citation.volume34-
dc.citation.number5-
dc.citation.startPage826-
dc.citation.endPage832-
dc.identifier.bibliographicCitationJOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, Vol.34(5) : 826-832, 2022-07-
Appears in Collections:
2. College of Dentistry (치과대학) > Dept. of Prosthodontics (보철과학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.