174 444

Cited 0 times in

Development of Total Lymphoid Irradiation (TLI)-Dedicated Shielding and Image-Guided System and Dose Evaluation Using 3D-Printed Rat Phantom

DC Field Value Language
dc.contributor.author김진성-
dc.contributor.author박광우-
dc.contributor.author안소현-
dc.date.accessioned2022-08-23T00:37:54Z-
dc.date.available2022-08-23T00:37:54Z-
dc.date.issued2022-05-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/189533-
dc.description.abstractPurpose: The purpose of this study is to propose a technique for delivering accurate doses in an image-guided system by developing an experimental setup optimized for total lymphoid irradiation (TLI) in rat lung transplantation. Materials and methods: In this study, a position-controlled shielding system was developed, and the dose was quantitatively evaluated using a 3D rat phantom and Gafchromic EBT3 film. In addition, we made our own image-guided system that allows the position of the rat and the shielding system to be confirmed during TLI. Results: As a result of using the position-controlled shielding system, it was found that the doses to the head and lungs were reduced by 93.1 and 87.4%, respectively, of the prescribed doses. In addition, it was shown that the position of the shielding system can be easily confirmed by using the image guidance system. Conclusion: A shielding apparatus that can control dose delivery according to the size of the rat can optimize the dose for TLI in rat lung transplantation.-
dc.description.statementOfResponsibilityopen-
dc.formatapplication/pdf-
dc.languageEnglish-
dc.publisherFrontiers Media-
dc.relation.isPartOfFRONTIERS IN VETERINARY SCIENCE-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.titleDevelopment of Total Lymphoid Irradiation (TLI)-Dedicated Shielding and Image-Guided System and Dose Evaluation Using 3D-Printed Rat Phantom-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Radiation Oncology (방사선종양학교실)-
dc.contributor.googleauthorDong Hyeok Choi-
dc.contributor.googleauthorSo Hyun Ahn-
dc.contributor.googleauthorKwangwoo Park-
dc.contributor.googleauthorSang Hyun Choi-
dc.contributor.googleauthorJin Sung Kim-
dc.identifier.doi10.3389/fvets.2022.832272-
dc.contributor.localIdA04548-
dc.contributor.localIdA01432-
dc.relation.journalcodeJ04115-
dc.identifier.eissn2297-1769-
dc.identifier.pmid35664845-
dc.subject.keyword3D-printed phantom-
dc.subject.keywordimage-guided radiotherapy-
dc.subject.keywordin vivo dosimetry-
dc.subject.keywordposition-controlled shielding system-
dc.subject.keywordrat-
dc.subject.keywordtotal lymphoid irradiation-
dc.contributor.alternativeNameKim, Jinsung-
dc.contributor.affiliatedAuthor김진성-
dc.contributor.affiliatedAuthor박광우-
dc.citation.volume9-
dc.citation.startPage832272-
dc.identifier.bibliographicCitationFRONTIERS IN VETERINARY SCIENCE, Vol.9 : 832272, 2022-05-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Radiation Oncology (방사선종양학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.