0 604

Cited 0 times in

Cited 4 times in

Thermal Dynamics of a Novel Radio-Frequency Device for Endoscopic Spine Surgery An Experimental Model

DC Field Value Language
dc.contributor.authorLee, Han Joo-
dc.contributor.authorHeo, Dong-Hwa-
dc.contributor.authorHan, Sang Kuy-
dc.contributor.authorChoi, Hae Won-
dc.contributor.authorKim, Seungtaek-
dc.contributor.authorCho, Byeong Chan-
dc.contributor.authorSong, Min Chul-
dc.contributor.authorYang, Sun Choel-
dc.contributor.authorLee, Kang Moo-
dc.contributor.authorLee, Mun-Hwan-
dc.contributor.authorYoon, Tae Ho-
dc.contributor.authorShin, Ju Ho-
dc.contributor.authorLee, Woo Cheol-
dc.contributor.authorPark, Jeong Yoon-
dc.date.accessioned2022-07-08T03:13:42Z-
dc.date.available2022-07-08T03:13:42Z-
dc.date.created2022-08-01-
dc.date.issued2022-05-
dc.identifier.issn0362-2436-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/188731-
dc.description.abstractStudy Design. Experimental study. Objective. In this study, the ambient temperature of a radiofrequency (RF) electrode tip was compared and analyzed in terms of products, mode, flow quantity, and flow rate. Summary of Background Data. Endoscopic spine surgery is a widely used operation for degenerative lumbar stenosis and herniated lumbar disc. To perform endoscopic spine surgery, dedicated instruments like a RF generator and electrode are essential. Methods. An evaluation system capable of measuring temperature under equal conditions at a certain distance from the electrode tip was manufactured. The distance between the electrode tip and the temperature sensor was set to 1, 5, and 10 mm. The flow quantities of 0, 50, 100, and 150 mL/min and the flow rates of 0, 0.20, 0.53, and 0.80 m/s were compared and statistically analyzed. Results. The temperatures measured in the experiments conducted on the four combinations of RF device showed similar values, and showed differences according to the characteristics of each mode of the RF. As the distance between the electrode tip and the temperature sensor increased, the temperature decreased, and as flow quantity or flow rate increased, the temperature decreased. The maximum temperatures differed significantly according to flow quantity, between flow quantities of 0 and 100 mL/min (P = 0.03) and between 0 and 150 mL/min (P <= 0.01). The maximum temperatures also differed significantly between the flow rate of 0 m/s, and the flow rates of 0.20, 0.53, and 0.80 m/s, with P <= 0.01 in all three comparisons. Conclusion. This is the first study in which we made a customized RF temperature evaluation system and verified the temperature changes in various environments. When irrigation was performed, we could confirm that the maximum temperature was less than 60 degrees C. Irrigation is considered essential in endoscopic spine surgery.-
dc.description.statementOfResponsibilityrestriction-
dc.languageEnglish-
dc.publisherLippincott Williams & Wilkins-
dc.relation.isPartOfSpine-
dc.relation.isPartOfSPINE-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.titleThermal Dynamics of a Novel Radio-Frequency Device for Endoscopic Spine Surgery An Experimental Model-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Neurosurgery (신경외과학교실)-
dc.contributor.googleauthorLee, Han Joo-
dc.contributor.googleauthorHeo, Dong-Hwa-
dc.contributor.googleauthorHan, Sang Kuy-
dc.contributor.googleauthorChoi, Hae Won-
dc.contributor.googleauthorKim, Seungtaek-
dc.contributor.googleauthorCho, Byeong Chan-
dc.contributor.googleauthorSong, Min Chul-
dc.contributor.googleauthorYang, Sun Choel-
dc.contributor.googleauthorLee, Kang Moo-
dc.contributor.googleauthorLee, Mun-Hwan-
dc.contributor.googleauthorYoon, Tae Ho-
dc.contributor.googleauthorShin, Ju Ho-
dc.contributor.googleauthorLee, Woo Cheol-
dc.contributor.googleauthorPark, Jeong Yoon-
dc.identifier.doi10.1097/BRS.0000000000004320-
dc.relation.journalcodeJ02674-
dc.identifier.eissn1528-1159-
dc.subject.keywordendoscopic spine surgery-
dc.subject.keywordnerve injury-
dc.subject.keywordradio frequency-
dc.subject.keywordthermal dynamics-
dc.contributor.alternativeNamePark, Jeong Yoon-
dc.contributor.affiliatedAuthorLee, Han Joo-
dc.contributor.affiliatedAuthorPark, Jeong Yoon-
dc.identifier.scopusid2-s2.0-85130634464-
dc.identifier.wosid000794859500008-
dc.citation.volume47-
dc.citation.number10-
dc.citation.startPage720-
dc.citation.endPage729-
dc.identifier.bibliographicCitationSpine, Vol.47(10) : 720-729, 2022-05-
dc.identifier.rimsid75350-
dc.type.rimsART-
dc.description.journalClass1-
dc.description.journalClass1-
dc.subject.keywordAuthorendoscopic spine surgery-
dc.subject.keywordAuthornerve injury-
dc.subject.keywordAuthorradio frequency-
dc.subject.keywordAuthorthermal dynamics-
dc.subject.keywordPlusINTRAARTICULAR FLUID TEMPERATURE-
dc.subject.keywordPlusSHOULDER ARTHROSCOPY-
dc.subject.keywordPlusLUMBAR-
dc.subject.keywordPlusSTENOSIS-
dc.subject.keywordPlusDECOMPRESSION-
dc.subject.keywordPlusCHONDROPLASTY-
dc.subject.keywordPlusENERGY-
dc.subject.keywordPlusDISKECTOMY-
dc.subject.keywordPlusCARTILAGE-
dc.subject.keywordPlusBIPOLAR-
dc.type.docTypeArticle-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalWebOfScienceCategoryClinical Neurology-
dc.relation.journalWebOfScienceCategoryOrthopedics-
dc.relation.journalResearchAreaNeurosciences & Neurology-
dc.relation.journalResearchAreaOrthopedics-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Neurosurgery (신경외과학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.