163 276

Cited 6 times in

Single-port transaxillary robotic thyroidectomy (START): 200-cases with two-step retraction method

DC Field Value Language
dc.contributor.author강상욱-
dc.contributor.author김진경-
dc.contributor.author남기현-
dc.contributor.author이초록-
dc.contributor.author정웅윤-
dc.contributor.author정종주-
dc.contributor.author최선형-
dc.contributor.author최순민-
dc.contributor.author최혜련-
dc.date.accessioned2022-07-08T03:13:17Z-
dc.date.available2022-07-08T03:13:17Z-
dc.date.issued2022-04-
dc.identifier.issn0930-2794-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/188728-
dc.description.abstractBackground: This study aims to report the results of a pioneering clinical study using the single-port transaxillary robotic thyroidectomy (START) for 200 patients with thyroid tumor and to introduce our novel two-step retraction method. Methods: START was performed on consecutive 200 patients using the da Vinci Single-Port (SP) robot system from January 2019 to September 2020 at the Yonsei University Health System, Seoul, Korea. The novel two-step retraction technique, in which a 3.5 cm long incision is made along the natural skin crease, was used for the latter 164 patients. The surgical outcome and invasiveness of the SP two-step retraction method were analyzed. Results: Among the 200 cases who underwent START, 198 were female and 2 were male, with a mean age of 34.7 (range: 13-58 years). Thyroid lobectomy was performed for 177 patients and total thyroidectomy was performed for 23 patients. Ten patients had benign thyroid nodules, whereas the other 190 had thyroid malignancy. The mean body mass index (BMI) was 22.2 ± 3.7 kg/m2 (range: 15.9-37.0 kg/m2). All of the operations were performed successfully without any open conversions, and patients were discharged on postoperative day 3 or 4 without significant complication. The mean operative time for thyroid lobectomy with the two-step retraction method was 116.69 ± 23.23 min, which was similar to that in the conventional robotic skin flap method (115.33 ± 17.29 min). We could minimize the extent of the robotic skin flap dissection with the two-step retraction method. Conclusions: START is a practical surgical method. By employing the new two-step retraction method, we can maximize the cosmetic and functional benefits for patients and reduce the workload fatigue of surgeons by increasing robotic dependency.-
dc.description.statementOfResponsibilityopen-
dc.formatapplication/pdf-
dc.languageEnglish-
dc.publisherSpringer-
dc.relation.isPartOfSURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.subject.MESHAdult-
dc.subject.MESHFemale-
dc.subject.MESHHumans-
dc.subject.MESHMale-
dc.subject.MESHNeck Dissection / methods-
dc.subject.MESHOperative Time-
dc.subject.MESHRobotic Surgical Procedures* / methods-
dc.subject.MESHRobotics* / methods-
dc.subject.MESHThyroid Neoplasms* / surgery-
dc.subject.MESHThyroidectomy / methods-
dc.subject.MESHTreatment Outcome-
dc.titleSingle-port transaxillary robotic thyroidectomy (START): 200-cases with two-step retraction method-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Surgery (외과학교실)-
dc.contributor.googleauthorJin Kyong Kim-
dc.contributor.googleauthorSun Hyung Choi-
dc.contributor.googleauthorSoon Min Choi-
dc.contributor.googleauthorHye Ryeon Choi-
dc.contributor.googleauthorCho Rok Lee-
dc.contributor.googleauthorSang-Wook Kang-
dc.contributor.googleauthorJong Ju Jeong-
dc.contributor.googleauthorKee-Hyun Nam-
dc.contributor.googleauthorWoong Youn Chung-
dc.identifier.doi10.1007/s00464-021-08837-9-
dc.contributor.localIdA00032-
dc.contributor.localIdA05739-
dc.contributor.localIdA01245-
dc.contributor.localIdA03256-
dc.contributor.localIdA03674-
dc.contributor.localIdA03722-
dc.contributor.localIdA05053-
dc.contributor.localIdA05941-
dc.relation.journalcodeJ02703-
dc.identifier.eissn1432-2218-
dc.identifier.pmid34741206-
dc.subject.keywordRobotic single-port thyroidectomy-
dc.subject.keywordRobotic single-port transaxillary thyroidectomy-
dc.subject.keywordRobotic thyroidectomy-
dc.subject.keywordRobotic transaxillary thyroidectomy-
dc.subject.keywordSTART-
dc.subject.keywordda vinci SP-
dc.contributor.alternativeNameKang, Sang Wook-
dc.contributor.affiliatedAuthor강상욱-
dc.contributor.affiliatedAuthor김진경-
dc.contributor.affiliatedAuthor남기현-
dc.contributor.affiliatedAuthor이초록-
dc.contributor.affiliatedAuthor정웅윤-
dc.contributor.affiliatedAuthor정종주-
dc.contributor.affiliatedAuthor최선형-
dc.contributor.affiliatedAuthor최순민-
dc.citation.volume36-
dc.citation.number4-
dc.citation.startPage2688-
dc.citation.endPage2696-
dc.identifier.bibliographicCitationSURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, Vol.36(4) : 2688-2696, 2022-04-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Surgery (외과학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.